Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (54)
- Vortrag (8)
- Posterpräsentation (6)
- Buchkapitel (2)
- Forschungsbericht (2)
Schlagworte
- GERG-2008 equation of state (6)
- Nanocomposite (6)
- Supercapacitor (6)
- Equations of state (5)
- Ionic liquid (5)
- Carbon dioxide (4)
- Density measurements (4)
- Ionic liquids (3)
- Mischphasenthermodynamik (3)
- Ringversuch (3)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (31)
- 1.4 Prozessanalytik (30)
- 1.0 Abteilungsleitung und andere (1)
- 5 Werkstofftechnik (1)
- 5.4 Multimateriale Fertigungsprozesse (1)
- 8 Zerstörungsfreie Prüfung (1)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (1)
- 8.4 Akustische und elektromagnetische Verfahren (1)
- 8.6 Faseroptische Sensorik (1)
Eingeladener Vortrag
- nein (8)
Zinc ferrite and graphene composites have attracted considerable attention in wastewater treatment. In this work, a magnetically separable mesoporous composite of ZnFe2O4 nanoparticles (NPs) and reduced graphene oxide (rGO) was prepared through a simple and eco-friendly method with pure water as solvent and without the need for subsequent thermal treatment. Uniformly dispersed ZnFe2O4 NPs on the surface of rGO sheets exhibited good crystallinity and a large BET specific surface area. These factors contributed to good photocatalytic performance of the composite for the degradation of methylene blue (MB) under simulated solar-light radiation, increased adsorptivity, increased separation efficiency of the photo-excited charges on the surface of the catalyst, and broadened light-absorption range of the composite. Efficient interfacial interaction between the ZnFe2O4 NPs and rGO sheets resulted in synergistic effects. The magnetically separable ZnFe2O4@rGO nanocomposite proved an efficient and stable catalyst in three consecutive photodegradation cycles for MB dye in aqueous solution under solar radiation. In addition, the synthesis method proposed in this study could be scaled-up easily due to the simplicity of the process, the lack of a toxic reagent, and the use of low temperatures.
In a mutual framework agreement, the two German national institutes BAM (Federal Institute of Materials Research and Testing) and PTB (Physikalisch-Technische Bundesanstalt) agreed upon the development, provision, and dissemination of national measurement standards for chemical analysis via primary reference measuring systems.
Traceability to national standards and international comparability is of key importance for the acceptance of measurement results in metrology.
The present study investigated decoration of Cu(OH)₂ with different morphologies by copper precursors on 3D nickel foam. The Cu(OH)₂-A (nano flower)electrode showed an excellent capacitance of 1332 Fg⁻¹ at current density of 2 Ag⁻¹ compared to the Cu(OH)₂-C (nano ribbon, 1100 Fg⁻¹) and Cu(OH)₂-S (nano Long leaf, 1013 Fg⁻¹) electrodes. An asymmetric supercapacitor (ASC) was fabricated and showed a Maximum capacitance of 165 Fg⁻¹ at current density of 2 Ag⁻¹ with high energy density of 66.7 Wh kg⁻¹ and power density of 5698 W kg⁻¹ with excellent stability of 80 % after 10,000 cycles.
Some homogeneous liquid mixtures of an ionic liquid and a lower alkanol (e.g., methanol) can be forced to undergo a liquidliquid phase split (resulting in a three-phase liquid–liquid–vapor (L1L2V) equilibrium) by pressurization with a gas. Such systems exhibit the phenomenon of "salting out by a nearcritical gas". That phenomenon is often observed at temperatures around the critical temperature of the gas in liquid mixtures where at least one of the liquid components is a good solvent for that gas. New experimental results for both the L1L2V equilibrium and the corresponding critical endpoint lines of the two ternary systems (carbon dioxide + methanol + 1-n-butyl-3-methylimidazolium hexafluorophosphate [bmim][PF6]) and (carbon dioxide + 1-butanol + 1-n-hexyl-3-methylimidazolium bis(trifluoromethylsulfonyl)amide [hmim][Tf2N]) at temperatures between 293 and 333 K are reported. The experiments were performed with an "analytical method". The liquid–liquid phase split exists only at pressures between a lower critical endpoint line (where both liquid phases become critical and coexist with a vapor phase) and an upper critical endpoint line (where one of the phases becomes critical with the vapor phase while the critical phases coexist with another liquid phase). The compositions of the coexisting three phases L1, L2, and V differ considerably; a high-density, ionic liquid-rich liquid phase (L1) coexists with an alkanol-rich liquid phase (L2) of lower density and a vapor phase (V) that is virtually ionic liquid-free. For both systems, it was observed that, at constant temperature, increasing pressure shifts the L1 phase towards higher contents of ionic liquid and gas and less alkanol, whereas in the L2 phase the mole fractions of ionic liquid and alkanol decrease. Higher temperatures result in a smaller difference between the pressures of both critical endpoint lines. Experimental results for both critical endpoint lines and for the compositions of the coexisting liquid phases are reported.
The requirement for a metrological infrastructure to ensure the interchangability of 'nonconventional’ energy gases within existing European infrastructure1 was the driving force behind the work undertaken in the three-year EMRP Characterisation of energy gases project EMRP ENG01 (June 2010 - May 2013).
As part of work package one of the project, Standards and methods were used to perform composition and impurity measurements on samples of real energy gases collected from around Europe. The aim of this study was to compare the results obtained from different labs, and thereby provide an evaluation of the labs’ capabilities and provide insight into the feasibility of different analytical methodologies for use with future measurements.
Energy harvested from intermittent sources can be stored in supercapacitors for high-power delivery with long cycling stability. Binary layered double hydroxide (LDH) materials have great potential for hybrid supercapacitor applications owing to their mixed and tunable charges and layered structure. This study presents carnation flower-like, 3D micro-structured NiMn-LDH prepared by a facile single-step hydrothermal synthesis using hexamethylenetetramine to produce hydroxides. The 3D structure was assembled from ultrathin 2D NiMn-LDH nanosheets, and the largest interlayer spacing was obtained by optimizing synthesis parameters, such as Ni:Mn molar ratio and reaction temperature, ensuring a fast diffusion and thus the best energy storage performance. The optimized NiMn-LDH electrode delivered a high specific capacity of 612 C/g with an excellent rate capability of 67% at 20 A/g in a three-electrode test. An asymmetric device assembled using NiMn-LDH and reduced graphene oxide as positive and negative electrodes provided a high energy density of 60.0 Wh/kg and power density of 17.7 kW/kg with 90.4% capacity retention after 10,000 charge–discharge cycles. This superior result highlights the potential industrial applications, such as portable electronics and trams.
There is a high international priority attached to activities which reduce NOx in the atmosphere. The current level of permitted emissions is typically between 50 µmol/mol and 100 µmol/mol, but lower values are expected in the future. Currently, ambient air quality monitoring regulations also require the measurement of NOx mole fractions as low as 0.2 µmol/mol. The production of accurate standards at these levels of mole fractions requires either dilution of a stable higher concentration gas standard or production by a dynamic technique, for example one based on permeation tubes.
The CCQM-K74 key comparison was designed to evaluate the level of comparability of National Metrology Institutes' measurement capabilities and standards for nitrogen dioxide (NO2) at a nominal mole fraction of 10 µmol/mol.
The measurements of this key comparison took place from June 2009 to May 2010.
Seventeen laboratories took part in this comparison coordinated by the BIPM and VSL. The key comparison reference value was based on BIPM measurement results, and the standard measurement uncertainty of the reference value was 0.042 µmol/mol.
This key comparison demonstrated that the results of the majority of the participants agreed within limits of ±3% relative to the reference value. The results of only one laboratory lay significantly outside these limits. Likewise this comparison made clear that a full interpretation of the results of the comparison needed to take into account the presence of nitric acid (in the range 100 nmol/mol to 350 nmol/mol) in the cylinders circulated as part of the comparison, as well as the possible presence of nitric acid in the primary standards used by participating laboratories.
Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.
The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
DatesIssue 1A (Technical Supplement 2012)
This pilot study compares the performance of participants in analyzing gas mixtures of nitrogen dioxide in nitrogen by comparison with in-house gravimetric standards using Fourier transformed infrared spectroscopy (FT-IR). In this study the same gas mixtures were used as in the key comparison CCQM-K74, which was designed to evaluate the level of comparability of National Metrology Institutes' measurement capabilities for nitrogen dioxide (NO2) at a nominal mole fraction of 10 µmol/mol. In the comparison CCQM-K74 most of the participants used chemiluminescence, with a small number using UV absorption or FT-IR spectroscopy, and thus it is of interest to improve understanding of the comparative performance of these techniques because they do not exhibit any cross-sensitivity to nitric acid (HNO3), which was known to be present in the mixtures used for the comparison.
The results of this pilot study indicate good consistency and a level of agreement similar to that reported in the comparison CCQM-K74, demonstrating that FT-IR can be operated as a comparison method when calibrated with appropriate gas standards and can achieve similar measurement uncertainties to chemiluminescence and UV absorption techniques.
An additional pilot study, CCQM-P110-B2, was conducted on the same gas mixtures in parallel with this pilot study. The second study addressed FT-IR spectroscopy when used to measure the gas mixtures with respect to reference spectra. The results of this second study will be reported elsewhere.
Main text. To reach the main text of this paper, click on Final Report.
The final report has been peer-reviewed and approved for publication by the CCQM-GAWG.
DatesIssue 1A (Technical Supplement 2012)
An accurate measurement of the amount fraction of hydrogen in gas mixtures is mandatory for practical applications, requiring methods that are fast, continuous, robust, and cost-effective. This study compares the performance of Raman and benchtop NMR process spectroscopy for determining the hydrogen amount fraction in gas mixtures. A setup was designed to integrate both techniques, enabling measurements of the same sample.
Tests were conducted with gravimetrically prepared gas mixtures of reference quality ranging from 1.20 cmol/mol to 85.83 cmol/mol of hydrogen. The results demonstrate that Raman spectroscopy provides superior performance, with a minimal root mean square error (RMSE) of 0.22 cmol/mol and excellent linearity. In contrast, benchtop NMR spectroscopy faced challenges, such as overlapping peaks and longer measurement times, resulting in a higher RMSE of 0.71 cmol/mol. Raman spectroscopy proves to be particularly well-suited for
practical applications due to its high accuracy and linearity. Meanwhile, benchtop NMR spectroscopy holds potential for future enhancements through ongoing technological advances, such as higher magnetic field strengths. In summary, the results from our study indicate that Raman spectroscopy is already a serviceable method for precise hydrogen quantification, whereas benchtop NMR spectroscopy can be attributed potential for future applications.