Filtern
Erscheinungsjahr
- 2014 (2)
Dokumenttyp
Sprache
- Englisch (2)
Referierte Publikation
- ja (2)
Schlagworte
- Mass spectrometry (2) (entfernen)
A commercially available airbrush gun as a new source for spray ionization is presented. It is best operated employing moderate stagnation pressures, resulting in a sonic gas flow. A mass spectrometric investigation on the amino acid lysine and several peptides reveals that this inexpensive approach results in reproducible mass spectra. The ion patterns strongly resemble the results from other studies obtained with custom made sonic spray vaporizers. The patterns as well resemble the mass spectra recorded with electrospray devices. For a better understanding of the vaporization process, the mass spectrometry experiments are accompanied by laser induced fluorescence experiments. Inverse Abel transform of the obtained fluorescence maps allows the determination of the full 3D distribution of the spray cone. Furthermore, via exploitation of the solvatochromism of the used dye the solvation state distribution can be visualized. In addition, expansion parameters like droplet size and velocity are obtained by laser stroboscopy. The experiments demonstrate that the analyte is hardly desolvated throughout the expansion. This indicates a subsequent vaporization of the residual solvent in the intermediate pressure region of the mass spectrometer.
New-found interest in the development of ionization sources for mass spectrometry, inspired by the advent of ambient desorption/ionization mass spectrometry, has led to a resurgence in plasma-source development and characterization. Dielectric-barrier discharges, particularly the low-temperature plasma (LTP) probe format, have been at the forefront of this field due to their low power consumption and relatively simple design. However, better fundamental understanding of this desorption/ionization source is needed to improve the analytical capabilities of such a device. Here, we use relatively fast (2.5 ms per spectrum) time-resolved mass spectrometry to characterize the temporal reagent-ion distribution from a low-frequency LTP probe. Different voltage waveforms were found to heavily influence the discharge properties and, consequently, ion production. Ion signals from short discharge pulses, ca. 40 µs, were found to be significantly broadened, ca. 10 ms, prior to extraction into the mass spectrometer. Additionally, higher frequencies of a sine-wave LTP produced the largest flux of reagent ions, which existed for most of the voltage waveforms. Finally, temporal signals for reagent and analyte ions were measured and related to specific ionization processes: proton transfer and charge transfer.