Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (29)
- Vortrag (26)
- Beitrag zu einem Tagungsband (20)
- Forschungsbericht (13)
- Beitrag zu einem Sammelband (11)
- Posterpräsentation (5)
- Sonstiges (2)
Schlagworte
- Aerosol (10)
- Laserdrucker (8)
- Cascade impactor (7)
- TXRF (7)
- Blauer Engel (6)
- Particles (6)
- Bürogeräte (5)
- Air quality monitoring (4)
- Emissionen (4)
- ICP-MS (4)
Organisationseinheit der BAM
- 4 Material und Umwelt (27)
- 4.2 Material-Mikrobiom Wechselwirkungen (24)
- 1 Analytische Chemie; Referenzmaterialien (2)
- 1.4 Prozessanalytik (2)
- 4.5 Kunst- und Kulturgutanalyse (2)
- 8 Zerstörungsfreie Prüfung (2)
- 8.0 Abteilungsleitung und andere (2)
- 9 Komponentensicherheit (2)
- 9.3 Schweißtechnische Fertigungsverfahren (2)
- 4.0 Abteilungsleitung und andere (1)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (26)
Zulassung von Schutzlagen
(1995)
Untersuchung der Wirksamkeit von Filtern zum Schutz vor Partikelemissionen aus Laserdrucksystemen
(2012)
Laserdrucksysteme (Laserdrucker, -kopierer, Multifunktionsgeräte) emittieren in sehr unterschiedlichen Mengen Partikel im Größenbereich zwischen 5 und 300 nm, die im Druckbetrieb überwiegend durch Kondensation aus der Gasphase entstehen. Eine präventive Minderung dieser Emissionen ist sinnvoll. Die Filtration der in Laserdruckern entstehenden Aerosole bietet eine Option für eine wirksame Emissionsminderung. Die untersuchten Filter mit verschiedenen Filterkonzepten zeigten in ihrer Wirkung deutliche Unterschiede. Die Ergebnisse unterstreichen die Notwendigkeit der gerätespezifischen Optimierung von Filtern für die Anwendung in Laserdrucksystemen.----------------------------------------------------------------------------------------------------------------------------------------------
Laser printing devices are sources of particle emission in different quantities in the size range between 5 and 300 nm. The particles are predominantly generated by re-condensation from the gas phase. Emission mitigation as a precautionary measure should be considered and exhaust air filtration is one technical option. Two particle filters with different filter concepts were compared and revealed different levels of performance. The result underpins the need for individual filter solutions for laser printing devices.
Partikelanalyse im Brandfall
(2013)
Geosynthetic clay liners (GCLs) often have a sandwich-like multilayer structure, e.g. bentonite encased between two geotextile layers connected by fibers or yarns, either by needle-punching or stitch-bonding. Therefore, the internal shear strength of the GCL depends on the strength of reinforcing fiber bundles or yarns and their anchoring strength in the cover and carrier geotextiles. When used on long and steep slopes and covered with thick soil layers, the GCL is permanently exposed to a combined action of compressive and shear stress. Such load conditions are characteristic for landfill covers and the slope stability of the overall cover system in the long run strongly depends on the long-term internal shear strength of the GCL. A new test method was developed to study this long-term shear behavior. The focus was not only on creep, as it is normally done, but on aging effects. The shear test devices allow the measurement of creep curves and times-to-failure at elevated temperatures in different media (tap water and de-ionized water). In this publication, the main findings of the experiments on needle-punched GCLs with and without thermal treatment are summarized. Tap water as a test medium was essential to ensure sodium to calcium ion exchange in the bentonite layer. Under this condition extremely long test durations without failure were achieved. Sliding failure occurred when de-ionized water was used. Two failure modes were observed: brittle failure of the GCLs with thermal treatment and slow disentanglement of fiber bundles for untreated GCLs. Short-term shear strength (e.g. peel strength) is unrelated to the actual long-term shear strength, i.e. to the times-to-failure achieved in long-term shear strength test. Hence, short-term shear strength alone will not provide reliable dimensioning data for product design and choice of resins. Therefore, the often suggested approach, namely, restriction to short-term tests only and application of factors of safety, is challenged by these results.