Filtern
Erscheinungsjahr
- 2013 (5) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (4)
- Vortrag (1)
Schlagworte
- 17alpha-Ethinylestradiol (1)
- 17beta-Estradiol (1)
- Assay format (1)
- Atrazine (1)
- Caffeine (1)
- Competitive assay (1)
- Direct (1)
- Endocrine disrupting compounds (1)
- Enzyme immunoassay (1)
- Enzyme substrate (1)
Eingeladener Vortrag
- nein (1)
This study comprises the development of enzyme-linked immunosorbent assays (ELISAs) for the quantification of 17β-estradiol (E2) and 17α-ethinylestradiol (EE2) in complex aqueous matrices without any sample clean-up procedures. Salinity and dissolved organic matter were selected as potential interfering agents in the analysis of E2 and EE2. The optimization was performed in order to (i) overcome matrix effects, and to (ii) increase sensitivity. The addition of a sample buffer containing bovine serum albumin (BSA) prior to the sample was found to decrease the influence of matrix effects. Moreover, adjustments of this buffer's pH together with the optimization of tracer (T) dilution and incubation time were undertaken in order to lower the quantification range. The optimized methods allowed the quantification of E2 and EE2 in the ranges 0.03200 µg L-1 and 0.0210 µg L-1, respectively. The assays were applied to real aqueous samples. It was possible to do a first approach to the levels of E2 in Portuguese surface and waste waters; however, it was not feasible to detect EE2 in the samples tested.
The implementation of the Water Framework Directive (2000/60/EC) requires the establishment of monitoring programs. However, conventional procedures for sample preparation prior to chromatographic analysis are rather expensive and time consuming, being the development of cost-effective and easy tool a necessity. The aim of this work was to develop an enzyme-linked immunosorbent assay (ELISA) able to determine atrazine in water samples. Matrix effects evaluation showed that the increase of humic acid (HA) concentration leads to flattened calibration curves and to the loss of the sigmoidal shape. However, such interference was overcome, by the presence of an environmental sample buffer, incubated together with the samples. Recoveries from 88.5 to 119.2 % were obtained in the presence of HA concentrations up to 20 mg-1. An analytical range from 0.003 to 1 µgL-1 was obtained, and atrazine was detected in a sewage treatment plant with concentrations ranging from 14 to 52 ngL-1.
Enzyme immunoassays with optical detection are amongst the most widely used bioanalytical tools. We defined seven parameters for the quality assessment of immunoassays that were addressed in a systematic study of direct and indirect immunoassays, using the enzymes horseradish peroxidase (HRP) and alkaline phosphatase (AP), the chromogenic substrates 3,3',5,5'-tetramethylbenzidine (TMB) and para-nitrophenyl phosphate, and the fluorescent substrates 3-(4-hydroxyphenyl)propionic acid and 4-methylumbelliferyl phosphate. The same monoclonal antibody against caffeine was used throughout the study. The four quality parameters regarding the standard curve were the test midpoint (sensitivity), the measurement range, the relative dynamic range of the signal, and the goodness of fit of the adjusted four-parameter logistic function. All HRP immunoassays showed a higher sensitivity compared to the AP assays. On the basis of all four criteria, it was established that the direct assay format is superior to the indirect format, the immunoassay using HRP TMB fulfilling all requirements best. In a second step, caffeine concentrations in 24 beverage and cosmetics samples were determined and three more quality parameters were assessed with this application. The direct HRP TMB assay showed one of the best intra- and inter-plate precisions and the best accuracy, defined by the correlation of results with those from the chosen reference method liquid chromatography tandem mass spectrometry (LC-MS/MS). Considering all criteria, HRP TMB seems to be the enzyme substrate system of choice preferably used in the direct assay format.
Carbamazepine (CBZ) is one of the most frequently detected pharmaceuticals in water samples. For the determination of this anthropogenic marker, various immunoassay formats were tested and evaluated in order to identify the most suitable one. For these direct competitive assays, the analyte was labelled with the enzyme horseradish peroxidase (HRP) or alkaline phosphatase (AP), and seven substrates with specific detection properties were used. The quality criteria for the standard curves were fulfilled by all HRP assays and the chemiluminescence AP format. Furthermore, intra- and inter-plate coefficients of variation as a measure of the achievable precision were determined for the samples. The application of the AP assays to surface water was unfeasible due to CBZ concentrations below the quantifiable concentration range. Surface as well as waste water samples could be analyzed with the HRP assays. Here, the HRP assay employing the chromogenic substrate 3,3',5,5'-tetramethylbenzidine yielded the best results.