Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (25)
- Vortrag (19)
- Posterpräsentation (2)
- Buchkapitel (1)
- Beitrag zu einem Tagungsband (1)
Schlagworte
- Immunoassay (48) (entfernen)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (19)
Monitoring carbamazepine in surface and wastewaters by an immunoassay based on a monoclonal antibody
(2009)
The pharmaceutical compound carbamazepine (CBZ) is an emerging pollutant in the aquatic environment and may potentially be used as a wastewater marker. In this work, an enzyme-linked immunosorbent assay (ELISA) for the detection of carbamazepine in surface and sewage waters has been developed. The heterogeneous immunoassay is based on a commercially available monoclonal antibody and a novel enzyme conjugate (tracer) that links the hapten via a hydrophilic peptide (triglycine) spacer to horseradish peroxidase. The assay achieves a limit of detection of 24 ng/L and a quantitation range of 0.05-50 µg/L. The analytical performance and figure of merits were compared to liquid chromatography-tandem mass spectrometry after solid-phase extraction. For nine Berlin surface water samples and one wastewater sample, a close correlation of results was observed. A constant overestimation relative to the CBZ concentration of approximately 30% by ELISA is probably caused by the presence of 10,11-epoxy-CBZ and 2-hydroxy-CBZ in the samples. The ELISA displayed cross-reactivities for these compounds of 83% and 14%, respectively. In a first screening of 27 surface water samples, CBZ was detected in every sample with concentrations between 0.05 and 3.2 µg/L. Since no sample cleanup is required, the assay allowed for the determination of carbamazepine with high sensitivity at low costs and with much higher throughput than with conventional methods.
High performance liquid chromatography (HPLC) was hyphenated with a previously reported carbamazepine-specific enzyme-linked immunosorbent assay (ELISA) as a screening approach to water analysis in order to identify possible interferences from transformation products. Treated wastewater was analysed and three substances were recognized by the antibody besides carbamazepine: the metabolites 10,11-dihydro-10,11-epoxycarbamazepine and 2-hydroxycarbamazepine plus the structurally not obviously related antihistamine cetirizine. The molar cross-reactivity against cetirizine was found to be pH-dependent and assessed to be 400% at pH 4.5 and 22% at pH 10.5. Performing the ELISA at pH 10.5 greatly improved the accuracy when carbamazepine was determined in surface and wastewater samples.
A large number of pharmacologically active compounds have been detected in the aquatic environment during the last decade [1] and this gives rise to many concerns [2]. The substances have been disclosed by accident, clever search or elaborate mass spectrometry. Nowadays a broad spectrum of drug parent compounds can be screened for [3], yet the knowledge about the presence of isomers and transformation products (metabolites, conjugates, degradates) is still limited.
Carbamazepine is a psychiatric pharmaceutical widely detected in aquatic environments. Due to its generalized occurrence and environmental persistence it might be considered as an anthropogenic pollution indicator. In this research, a previously developed enzyme-linked immunosorbent assay (ELISA), based on a commercial monoclonal antibody, was applied to the quantification of carbamazepine in ground, surface and wastewaters and results were validated by liquid chromatographytandem mass spectrometry (LCMS/MS).
The performance of the applied ELISA methodology was tested in the presence of high concentrations of sodium chloride and dissolved organic matter. The method was not significantly affected by matrix effects, being adequate for the quantification of carbamazepine in environmental samples, even without sample pre-treatment. This method allows the quantification of carbamazepine in the range of 0.0310 µg L-1, with a relative error lower than 30%. Due to a pH dependent cross-reactivity with cetirizine, an antihistaminic drug, the assay also enabled the quantification of cetirizine in the samples.
The application of the developed method to the quantification of carbamazepine was performed by using environmental samples with very different matrices, collected in the geographical area of Ria de Aveiro, an estuarine system located in the North of Portugal. Carbamazepine was detected in all analyzed wastewater samples and in one surface water with concentrations between 0.1 and 0.7 µg L-1. Validation with LCMS/MS revealed that results obtained by ELISA are 228% overestimated, which was considered highly satisfactory due to the absence of sample pre-treatments.
The synthetic estrogen ethinylestradiol (EE2) is an active component of oral contraceptives (OCs), considered as an endocrine disrupting compound (EDC). It is excreted from humans and released via sewage treatment plant effluents into aquatic environments. EDCs are any environmental pollutant chemical that, once incorporated into an organism, affects the hormonal balance of various species including humans. Its presence in the environment is becoming of great importance in water quality. This paper describes the development of an accurate, sensitive and selective method for capture, preconcentration and determination of EE2 present in water samples using: magnetic particles (MPs) as bioaffinity support for the capture and preconcentration of EE2 and a glassy carbon electrode modified with multi-walled carbon nanotubes (MWCNTs/GCE) as detection system. The capture procedure was based on the principle of immunoaffinity, the EE2 being extracted from the sample using the anti-EE2 antibodies (anti-EE2 Ab) which were previously immobilized on MPs. Subsequently the analyte desorption was done employing a sulfuric acid solution and the determination of the EE2 in the pre-concentrated solution was carried out by square wave voltammetry (SWV).
This method can be used to determine EE2 in the range of 0.03570 ng L-1 with a detection limit (LOD) of 0.01 ng L-1 and R.S.D. < 4.20%. The proposed method has been successfully applied to the determination of EE2 in water samples and it has promising analytical applications for the direct determination of EE2 at trace levels.
Temperature is one factor that influences the performance of immunoassays. Most commonly all incubation steps of the immunoassay are performed at ambient temperature. To systematically study the influence of temperature deviations on assay parameters like signal variation coefficients, limit of detection and measurement range, direct competitive enzyme immunoassays for the determination of two anthropogenic markers, caffeine and carbamazepine, were run at different temperatures above and below room temperature during individual assay steps. The temperature during the competition step had the greatest impact on the assay sensitivity yielding changes in test midpoints by a factor of 10 to 15. For carbamazepine, the test midpoints varied from 36 ng L-1, 108 ng L-1 to 378 ng L-1 employing 4 °C, 21 °C, or 37 °C as incubation temperature, respectively. The edge effect can be minimized resulting in a good plate homogeneity with small variation coefficients, when the assay is performed at ambient temperature.
The implementation of the Water Framework Directive (2000/60/EC) requires the establishment of monitoring programs. However, conventional procedures for sample preparation prior to chromatographic analysis are rather expensive and time consuming, being the development of cost-effective and easy tool a necessity. The aim of this work was to develop an enzyme-linked immunosorbent assay (ELISA) able to determine atrazine in water samples. Matrix effects evaluation showed that the increase of humic acid (HA) concentration leads to flattened calibration curves and to the loss of the sigmoidal shape. However, such interference was overcome, by the presence of an environmental sample buffer, incubated together with the samples. Recoveries from 88.5 to 119.2 % were obtained in the presence of HA concentrations up to 20 mg-1. An analytical range from 0.003 to 1 µgL-1 was obtained, and atrazine was detected in a sewage treatment plant with concentrations ranging from 14 to 52 ngL-1.
This study comprises the development of an enzyme-linked immunosorbent assay (ELISA) for the quantification of caffeine in complex aqueous matrices without any sample clean-up procedure. Salinity and dissolved organic matter were selected as potential interfering agents. The addition of a sample buffer containing bovine serum albumin (BSA) prior to the sample was found to decrease the influence of those interfering agents. The working range of the developed method was 0.1–100 µg L- 1. Quantification of caffeine was possible in 43 out of 51 real aqueous samples, at values between < LOD and 15 µg L- 1. Results correlate well with those obtained by LCMS/MS. To the best of our knowledge this is the first study dealing with the quantification of caffeine in Portugal's surface waters.