Filtern
Dokumenttyp
- Zeitschriftenartikel (15)
- Vortrag (15)
- Beitrag zu einem Tagungsband (1)
- Posterpräsentation (1)
Schlagworte
- Immunoassay (32) (entfernen)
Organisationseinheit der BAM
- 1.8 Umweltanalytik (32) (entfernen)
Eingeladener Vortrag
- nein (15)
Increasing contamination of environmental waters with pharmaceuticals represents an emerging threat for the drinking water quality and safety. In this regard, fast and reliable analytical methods are required to allow quick countermeasures in case of contamination. Here, we report the development of a magnetic bead-based immunoassay (MBBA) for the fast and cost-effective determination of the analgesic diclofenac (DCF) in water samples, based on diclofenac-coupled magnetic beads and a robust monoclonal anti-DCF antibody. A novel synthetic strategy for preparation of the beads resulted in an assay that enabled for the determination of diclofenac with a significantly lower limit of detection (400 ng/L) than the respective enzyme-linked immunosorbent assay (ELISA). With shorter incubation times and only one manual washing step required, the assay demands for remarkably shorter time to result (< 45 min) and less equipment than ELISA. Evaluation of assay precision and accuracy with a series of spiked water samples yielded results with low to moderate intra- and inter-assay variations and in good agreement with LC–MS/MS reference analysis. The assay principle can be transferred to other, e.g., microfluidic, formats, as well as applied to other analytes and may replace ELISA as the standard immunochemical method.
Immunoassays, based on the recognition and capture of analytes by highly selective antibodies, are now used extensively in all areas of diagnostics, but the challenge is to further integrate them into online sensors. To improve the transition from laboratory immunoassays to immunosensors, we have developed a complete flow system, based on a microfluidic core flow cell to enable automated detection of one of the most commonly used immunoassay substrates, TMB, by chronoamperometry. The architecture and fluidic optimisation of the system showed that a specially designed 3D flow cell allows higher flow rates (500 μL min−1) than a standard enlarged microfluidic channel (50 μL min−1) resulting in a significantly shorter detection time of 30 seconds per sample and making the system more robust against interferences due to bubble formation in the chip. The electrochemical measurements showed an improved signal-to-noise ratio (SNR) and thus higher sensitivity for a model immunoassay for diclofenac (SNR = 59), compared to the analytical performance of a conventional laboratory microplate-based assay with optical detection (SNR = 19). In general, this system facilitates the conversion of any conventional immunoassay into an immunosensor with automatic and continuous detection.
Immunoanalytical Techniques, i.e., antibody-based analytical methods, have been used for decades in clinical diagnostics. What makes them attractive for other fields of application is their short time-to-result and high sensitivity. Microplate-based assays such as ELISA have been adopted early in environmental and food analysis. Yet, to make immunoassays even faster, more sensitive, robust, and, most desirable, portable, advanced materials, sometimes developed for other purposes, can be profitably used to achieve these goals. Materials can be novel labels, e.g., chemical or particle labels, such as fluorophores or nanoparticles. Carrier particles, such as magnetic or polymer beads, make it possible to adopt the assays to meso- or microfluidic set-ups and encoding them opens the path to multiplex analysis. Specialty electrodes can enable for higher sensitivity in electrochemical detection. All this broadens the scope of application and lowers effort and cost for analysis at the point-of-need.
Antibody-based analytical techniques have gained increasing importance in environmental analysis. Rapid assays, portable devices and formats that require a limited number of steps have a high potential for on-site analysis in outdoor environments or in environmentally relevant facilities such as wastewater treatment plants. Many of these methods have become more sensitive and more versatile due to new, advanced materials, such as novel particles, specifically prepared surfaces, new labels, specifically coated electrodes etc. The talk shows some of our works in this context.
In urban waters, a multitude of organic micropollutants, often termed emerging pollutants, has been found over the last decades. Analytical methods suitable for trace analysis are needed that are desirably also fast, inexpensive and, if possible, robust and portable. Immunoanalytical, i.e., antibody-based, methods which are available in a broad range of formats, can be profitably used here to screen for the distribution and to monitor the trends of concentration levels of contaminants of emerging concern in the environment. Some of these formats are single-analyte but high-throughput methods. To use them wisely, indicator substances, sometimes called anthropogenic markers, should be selected and used in screening approaches, i.e., as indicators for contamination and the pre-selection of samples at which to have a closer look by multiplex methods like LC-MS/MS. Other methods are suitable to be performed on portable instrumentation in the field (on-site) or in facilities such as wastewater treatment plants for on-line monitoring of the treatment and elimination process. Furthermore, array technologies have been established that allow for parallel (multiplex) analysis of several analytes of interest.
The microtiter-plate based ELISA (Enzyme-linked Immunosorbent Assay) is the method of choice for the analysis of a large number of samples [1]. ELISAs are available to monitor for anthropogenic markers such as the antiepileptic carbamazepine, the analgesic diclofenac, the antihistaminic cetirizine, the steroid hormone estrone, the antimicrobial sulfamethoxazole, psychoactive caffeine and cocaine, the priority pollutant bisphenol A, and the bile acid isolithocholic acid. For on-site screening and monitoring, simpler formats, like mix-and-read assays, e.g., the Fluorescence Polarization Immunoassay (FPIA) [2] or Lateral-flow Immunoassays (LFIA) [3] are more suitable tools, the latter based on dipsticks or little cassettes, with which users have become very familiar during the COVID-19 pandemic via rapid antigen tests. The suitability of multi-analyte formats such as immunomicroarrays depends on the choice of a signal-producing system that provides small uncertainties and good reproducibility of the measurements. Bead-based (“suspension”) arrays, read out in flow cytometers, are a powerful platform for multiplex assays [4]. Electrochemical formats, run on portable devices, provide additional advantages as no light source is required. They are most promising for stand-alone analysers and biosensors [5].
The speed, low cost and on-site capabilities of these methods allow to gather a lot more data on anthropogenic compounds which enables to quantify inputs, differences in degradation power of elimination processes, dilution phenomena and a more precise image of individual water cycles which is demonstrated by several examples.
Der Vortrag beschreibt den Stand der Arbeiten an der BAM, Fachbereich Umweltanalytik zur Entwicklung von Sensoren für die Wasseranalytik. Er stellt die bisherigen Arbeiten da, die ausgehend von ELISAs, zunehmend portable Plattformen wie FPIA und LFIA umfassen. Beas-based Formate werden von mikrotiterplatten-basierten Techniken auf mikrofluidische Lab-on-Chip-Systeme übertragen, die bei geeigneter Miniaturisierung und Automatisierung als Sensorsysteme angesehen werden können. Der Vortrag endet mit einem Blick auf ein laufendes Monitoring-Projekt von anthropogenen Markern in Abwasser und charakterisiert die Treiber, die die Entwicklung von Sensoren für die Wasseranalytik in den letzten Jahren vorantreiben.
ESI-CorA ist ein nationales Verbundprojekt mit dem Ziel des Nachweises von SARS-CoV-2 im Abwasser.
Das UBA hat als Teilprojekt das Projekt MARKERIA (VH1802) an die BAM vergeben.
Ziel des Projektes ist es, die Eignung der Bestimmung eines oder mehrerer der genannten anthropogenen Marker im Abwasser zur Volumenkorrektur („Kalibration“) im SARS-CoV-2-Monitoring von Abwässern auf der Basis eines von der BAM zu erhebenden Messdatensatzes zu evaluieren.
Vortrag zum Kick-off des Projektes.
Ziel des Projektes ist es, die Eignung der Bestimmung eines oder mehrerer der genannten anthropogenen Marker im Abwasser zur Volumenkorrektur („Kalibration“) im SARS-CoV-2-Monitoring von Abwässern auf der Basis eines von der BAM zu erhebenden Messdatensatzes zu evaluieren.
1. Projektreffen mit dem Umweltbundesamt für das Projekt MARKERIA (VH1802).
Ziel des Projektes ist es, die Eignung der Bestimmung eines oder mehrerer der genannten anthropogenen Marker im Abwasser zur Volumenkorrektur („Kalibration“) im SARS-CoV-2-Monitoring von Abwässern auf der Basis eines von der BAM zu erhebenden Messdatensatzes zu evaluieren.
2. Projekttreffen mit dem Umweltbundesamt zum Projekt MARKERIA (VH1802).
Ziel des Projektes ist es, die Eignung der Bestimmung eines oder mehrerer der genannten anthropogenen Marker im Abwasser zur Volumenkorrektur („Kalibration“) im SARS-CoV-2-Monitoring von Abwässern auf der Basis eines von der BAM zu erhebenden Messdatensatzes zu evaluieren.