Filtern
Dokumenttyp
- Zeitschriftenartikel (8)
- Posterpräsentation (7)
- Beitrag zu einem Tagungsband (2)
- Vortrag (2)
- Forschungsbericht (2)
Schlagworte
- IDMS (5)
- TIMS (3)
- ICP-MS (2)
- ICPMS (2)
- Surface analysis (2)
- Zinc (2)
- Areal density (1)
- Bodenanalyse (1)
- Branching ratio (1)
- CCQM-P107 (1)
Eingeladener Vortrag
- nein (2)
The quantitative analysis of toxic metals in plastics is very important for different sectors of industry and daily life. Many routine procedures have been established based on X-ray fluorescence or inductively coupled plasma atomic emission spectrometry. However, all of them require suitable reference materials to calibrate or validate. These reference materials ideally are being certified by reference procedures. The development of such reference procedures for sulfur and the four toxic elements cadmium, chromium, mercury and lead in plastics is described here. The procedures are based on double isotope dilution mass spectrometry including analyte–matrix separation. The applied mass spectrometric techniques are thermal ionization mass spectrometry as well as inductively coupled plasma mass spectrometry. Memory effects of mercury and dissolution of chromium(III) oxide have been considered especially. The expanded uncertainties have been improved from the percent range down to the per mill range during the development of the procedure from the early analysis of BCR-680/681 to the recent analysis of CCQM-P106. With the fully developed procedures expanded uncertainties (k = 2) between 0.1 and 0.4% for cadmium, chromium, lead and sulfur and around 1% for mercury can be achieved. The so developed procedures have been successfully applied to the certification of reference materials as well as to intercomparisons organized by CCQM.
Within the National Metrology Institutes (NMIs) and designated laboratories, an interlaboratory comparison, CCQM-P107, was conducted to verify the degree of international comparability concerning the results of purity analysis. The mass fractions of Ag, Bi, Cd, Cr, Ni, Tl at the lower mg/kg-level in a high purity zinc material were determined, but the real measurand in metrological sense was the sum of the six mass fractions. Homogeneity was investigated by glow discharge mass spectrometry, reference values were obtained using isotope dilution mass spectrometry. Six NMIs participated, contributing eight independent data sets. The agreement amongst the results of the participants, their median and the agreement with the reference values were usually excellent and in almost all cases below the target uncertainty of 30% relative. In this manner, the accuracy of results and the comparability between the participants was demonstrated to be established.
Bestimmung von Platin in Autokatalysatoren mit massenspektrometrischer Isotopenverdünnungsanalyse
(2006)
An ICP-MS equipped with collision cell, sector field and multi-collector technology has been applied to developing analytical procedures for Fe in terms of isotope ratio measurements and isotope dilution analysis. Therefore a detailed study on the reduction of molecular interferences by a variety of collision gases (He, Ar, Kr, H2, D2 and N2) was performed. The efficiency of the reduction has been checked by high resolution mass scans. The argon based interferences disturbing the determination of 54Fe and 56Fe could be completely removed when using Faraday detectors. The interferences on mass 57 could be reduced to a level which enables accurate measurements. Also, the 40Ar12C interference, which disturbs the chromium correction, could be completely removed. Reproducibilities of 0.01% could be reached for 54Fe/56Fe isotope ratios and 0.02% for 57Fe/56Fe isotope ratios. Under these measurement conditions a sensitivity of 1.2 V per 50 µg kg1 Fe is available. This corresponds to 1.5 × 109 cps per mg kg1. Based on these results highly accurate procedures for Fe isotope ratio determinations were set up, reaching a performance level superior to that of other ICP-MS instruments. Consequently, IDMS procedures were developed on this basis in order to perform certification measurements at the highest metrological level. The first application was the contribution to the Fe reference value by IMEP-12, an interlaboratory comparison with approximately 350 participants worldwide. The analysed Fe mass content is 0.2150 mg kg1 with its expanded uncertainty (k= 2) of 0.0012 mg kg1(0.56%), which is ten times less than the uncertainty of the second certification laboratory. Another application was the certification campaign of the two reference materials Tea Leaves and Polish Herbs. The results obtained with the ICP-MS procedure, 542 ± 11 mg kg1 and 543 ± 12 mg kg1, were compared with the results analysed by TIMS, 541 ± 12 mg kg1 and 541 ± 13 mg kg1, and agree very well within the stated uncertainties (k= 2). The results presented demonstrate quite well the suitability of the developed IDMS procedures for certification or reference measurements.
The ?- branching ratio of 64Cu was determined by investigating the resulting decay products in copper doped by neutron transmutation. The numbers of 64Zn and 64Ni atoms were analyzed using isotope dilution analysis combined with thermal ionization mass spectrometry. A ?- branching ratio of (38.06±0.30)% was obtained, which agrees with the study of Kawada (Appl. Radiat. Isot. 37 (1) (1986) 7) to a higher accuracy. However, our result differs from the value cited in the NUDAT database of (39.0±0.3)%.
Chemische Probenvorbereitung
(2002)