Chloride-induced damage of reinforcing steel is especially for parking garages and bridges often very severe as large amounts of chlorides act on horizontal surfaces which could lead to fast ingress of these detrimental ions up to the level of the reinforcement and subsequently to high rates of corrosion.
In order to avoid the disadvantages of conventional rehabilitation (unreliable prognosis with patch repair or high costs and regular maintenance with cathodic protection using impressed current) a new combined protection system was developed where the principle of drying out the concrete (by means of a surface protection system) is combined with a temporary cathodic protection (by means of a sprayed zinc layer) during the transitional period of the drying out process.
This new system was tested both in the laboratory and on-site at a pilot application. Based on the results obtained the possibilities and limitations of the new system are discussed in this paper.
The paper presents the damage model of German Research Unit 537 which was used as a working hypothesis for the development of a user-friendly design model. Excerpts from the laboratory experiments and numerical calculations processed in project A of the research unit are presented here. The excerpts include the quantification of self-corrosion, geometrical effects in the macrocell corrosion, development of corroding steel surface and pit depth as well as the quantification of the resistivity of the concrete and the corrosion of steel in cracked concrete.