Filtern
Erscheinungsjahr
- 2011 (21) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (21)
Sprache
- Englisch (21) (entfernen)
Referierte Publikation
- ja (21)
Schlagworte
- LIBS (2)
- Acceptance area (1)
- Biosensor development (1)
- Calibration (1)
- Carbamazepin (1)
- Cetirizin (1)
- Chemical analysis (1)
- Dairy cows (1)
- Double-pulse LIBS (1)
- Droplet (1)
- EDS (1)
- ELISA (1)
- Encapsulation (1)
- FWHM (1)
- Feed (1)
- Firework display (1)
- Fixed-points (1)
- Fluorescence (1)
- Focal distance (1)
- Glow discharge (1)
- ITS-90 (1)
- Immunoassay (1)
- Impurities (1)
- Kreuzreaktivität (1)
- Laser induced plasma (1)
- Laser-induced breakdown spectroscopy (1)
- MALDI (1)
- MALDI Massenspektrometrie (1)
- Mass spectrometry imaging (1)
- Microparticles (1)
- Milk (1)
- Molten glass (1)
- Multi-element screening (1)
- Nanoparticles (1)
- Nile red (1)
- Organic peroxides (1)
- Parallelising mode (1)
- Particle size range (1)
- Particulate matter (1)
- Pin sample (1)
- Plasma tomography (1)
- Polycapillary X-ray optics (1)
- Polymer (1)
- Polymerisation (1)
- Polystyrene (1)
- Radon transform (1)
- Recycling (1)
- SEM (1)
- SF-ICP-MS (1)
- Semi-lens (1)
- Swelling (1)
- Terrorism (1)
- Threshold values (1)
- Transmission (1)
- Ultraschallfalle (1)
- Water (1)
- XRF (1)
- pH-Abhängigkeit (1)
A mobile double-pulse laser-induced breakdown spectroscopy system for industrial environments is presented.
Its capabilities as a process analytical technique for the recovery of metals from molten inorganic wastes are investigated. Using low-melting glass doped with different amounts of additives as a model system for recycling slags, the optimum number of shots, laser inter-pulse and acquisition delay times are optimized for solid and liquid (1200 °C) glass. Limits of detection from 7 ppm (Mn) to 194 ppm (Zn) are achieved working at a distance of 75 cm from the sample. To simplify the quantification of molten samples in an industrial furnace, the possibility is examined of using solid standards for analysis of molten material.
A new setup for fast spatially resolved measurements of elemental trace amounts under total reflection conditions using a new colour X-ray camera is described. Samples prepared on conventional total reflection X-ray fluorescence (TXRF) reflectors were measured at BESSY II synchrotron. A spatial resolution of 50 × 50 µm² was obtained, while the required time for the investigation of a 10 × 10 mm² sample is 30 seconds. The set-up is up to 350 times faster than conventional X-ray fluorescence systems for elemental traces. The major components of the X-ray camera are polycapillary optics and a pn-CCD chip with an active area of 13 × 13 mm². This area is divided into 264 × 264 pixels of 48 × 48 µm². A full X-ray spectrum with a resolution of 152 eV @ 5.9 keV and a chip temperature of 246 K is recorded for each pixel. The chip has a read-out rate of 400 Hz.
Encapsulation of hydrophobic dyes in polystyrene micro- and nanoparticles via swelling procedures
(2011)
Aiming at the derivation of a generalized
procedure for the straightforward preparation of particles
fluorescing in the visible and near-infrared (NIR) spectral
region, different swelling procedures for the loading of the
hydrophobic polarity-probe Nile Red into nano- and
micrometer sized polystyrene particles were studied and
compared with respect to the optical properties of the
resulting particles. The effect of the amount of incorporated
dye on the spectroscopic properties of the particles was
investigated for differently sized beads with different
surface chemistries, i.e., non-functionalized, aminomodified
and PEG-grafted surfaces. Moreover, photostability
and leaking studies were performed. The main criterion
for the optimization of the dye loading procedures was a
high and thermally and photochemically stable fluorescence
output of the particles for the future application of these
systems as fluorescent labels.
The accurate knowledge of the properties of polycapillary X-ray semi-lenses has a significant influence on the quantitative results in a widespread field of applications involving microfocus X-ray beams. A routine procedure for the characterisation of a polycapillary X-ray semi-lens with a scanning electron microscope (SEM) having attached an energy dispersive spectrometer (EDS) is presented in this paper. A key issue of the procedure consists of fitting the semi-lens in front of the EDS for spectra acquisition. Relevant semi-lens parameters such as focal distance, full width at half maximum (FWHM) of the acceptance area, and transmission are determined in parallelising mode of the semi-lens. Special attention has been paid to the calculation of the transmission.
During the mineralisation of metal carbonates MCO3 (M = Ca, Sr, Ba, Mn, Cd, Pb) liquid-like amorphous intermediates emerge. These intermediates that form via a liquid/liquid phase separation behave like a classical emulsion and are stabilized electrostatically. The occurrence of these intermediates is attributed to the formation of highly hydrated networks whose stability is mainly based on weak interactions and the variability of the metal-containing pre-critical clusters. Their existence and compositional freedom are evidenced by electrospray ionization mass spectrometry (ESI-MS). Liquid intermediates in non-classical crystallisation pathways seem to be more common than assumed.
Calibration of two commercially available glow discharge double focusing mass spectrometers, the VG 9000 and Element GD, is described using synthetic pin standards pressed from solution doped copper and zinc matrices. A special pressing die was developed for this purpose and optimal results were obtained with the highest possible pressures, i.e., 95 kN·cm- 2. This calibration approach permits the determination of trace element mass fractions down to µg·kg- 1 with small uncertainties and additionally provides traceability of the GD-MS results in the most direct manner to the SI (International System of Units). Results were validated by concurrent measurements of a number of compact copper and zinc certified reference materials. The impact of the sample pin cross-section (circular or square) was investigated with the use of a new pin-sample holder system for the Element GD. The pin-sample holder was designed by the manufacturer for pin-samples having circular cross-section; however, samples with square pin cross-section were also shown to provide acceptable results. Relative Sensitivity Factors for some 50 analytes in copper (VG 9000, Element GD) and zinc matrices (VG 9000) are presented. The field of applicability of GD-MS may be considerably extended via analysis of pin geometry samples based on their ease of preparation, especially with respect to the accuracy and traceability of the results and the enhanced number of analytes which can be reliably calibrated using such samples.
Abel inversion applied to a transient laser induced plasma: implications from plasma modeling
(2011)
We test the effects of non-uniformity, non-transparency, and non-stationarity of a laser-induced plasma on the results obtained by the Abel inversion method. The method is commonly used for obtaining spatially resolved emissivity of axially symmetric non-homogeneous radiating objects. Besides the axial symmetry, the plasma is assumed to be optically thin. As the method addresses a certain plasma state, the plasma is required to be stationary during measurements. It is difficult to satisfy the aforementioned conditions for transient laser induced plasmas. As such the plasmas are not stationary; they have steep gradients of thermodynamic parameters that rapidly vary during the plasma evolution. Therefore, any conclusion based on time-integrated measurements and the corresponding data processing should account for these effects. In this work, we use the collision-dominated plasma model to generate time- and spatially resolved synthetic spectra. The spectra are processed by executing the Abel inversion using two numerical algorithms. Thus obtained spatially resolved plasma parameters (emissivity, temperature, and number density) are compared with the exact parameters used to set up the model. In doing so, the accuracy of the Abel inversion method is assessed. Special attention is paid to the dynamic aspect of the expanding plasma and possible errors which result from time-integrated measurements.
Matrix-assisted laser desorption/ionization-timeof-flight (MALDI-TOF) imaging of polystyrenes with various molecular masses was applied to study spatial molecular mass distribution of polymers in sample spots prepared by the 'dried droplet' method. When different solvents and target surfaces were examined, a segregation of single homologous polymers was observed depending upon the evaporation rate of the solvent. For the observed Patterns left by the evaporating droplet, a hypothesis is offered taking into account different hydrodynamic interactions and diffusion.
The results illustrate that spot preparation using the conventionally 'dried droplet' method is prone to artifacts and should be avoided for reliable and reproducible MALDI mass spectrometry experiments with regards to the Determination of molecular masses and mass distributions.
Triacetone triperoxide (TATP) is a primary explosive, which was used in various terrorist attacks in the past. For the development of biosensors, immunochemical µ-TAS, electronic noses, immunological test kits, or test strips, the availability of antibodies of high quality is crucial. Recently, we presented the successful immunization of mice, based on the design, synthesis, and conjugation of a novel TATP derivative. Here, the long-term immunization of rabbits is shown, which resulted in antibodies of extreme selectivity and more than 1,000 times better affinity in relation to the antibodies from mice. Detection limits below 10 ng L-1 (water) were achieved. The working range covers more than four decades, calculated from a precision profile. The cross-reactivity tests revealed an extraordinary selectivity of the antibodies—not a single compound could be identified as a relevant cross-reactant. The presented immunoreagent might be a major step for the development of highly sensitive and selective TATP detectors particularly for security applications.
A laser ablation inductively coupled plasma mass spectrometry (LA–ICP–MS)-based methodology is presented for Pt, Cu, and Zn bioimaging on whole kidney 3 µm sagittal sections from rats treated with pharmacological doses of cisplatin, which were sacrificed once renal damage had taken place. Pt turned out to accumulate in the kidney cortex and corticomedullary junction, corresponding to areas where the proximal tubule S3 segments (the most sensitive cells to cisplatin nephrotoxicity) are located. This demonstrates the connection between platinum accumulation and renal damage proved by histological examination of HE-stained sections and evaluation of serum and urine biochemical parameters. Cu and Zn distribution maps revealed a significant displacement in cells by Pt, as compared to control tissues. A dramatic decrease in the Pt accumulation in the cortex was observed when cilastatin was coadministered with cisplatin, which can be related to its nephroprotective effect. Excellent imaging reproducibility, sensitivity (LOD 50 fg), and resolution (down to 8 µm) were achieved, demonstrating that LA–ICP–MS can be applied as a microscopic metal detector at cellular level in certain tissues. A simple and quick approach for the estimation of Pt tissue levels was proposed, based on tissue spiking.