Filtern
Erscheinungsjahr
- 2011 (25) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (21)
- Vortrag (3)
- Beitrag zu einem Tagungsband (1)
Schlagworte
- LIBS (2)
- Acceptance area (1)
- Biosensor development (1)
- Calibration (1)
- Carbamazepin (1)
- Cetirizin (1)
- Chemical analysis (1)
- Dairy cows (1)
- Double-pulse LIBS (1)
- Droplet (1)
Eingeladener Vortrag
- nein (3)
A mobile double-pulse laser-induced breakdown spectroscopy system for industrial environments is presented.
Its capabilities as a process analytical technique for the recovery of metals from molten inorganic wastes are investigated. Using low-melting glass doped with different amounts of additives as a model system for recycling slags, the optimum number of shots, laser inter-pulse and acquisition delay times are optimized for solid and liquid (1200 °C) glass. Limits of detection from 7 ppm (Mn) to 194 ppm (Zn) are achieved working at a distance of 75 cm from the sample. To simplify the quantification of molten samples in an industrial furnace, the possibility is examined of using solid standards for analysis of molten material.
Encapsulation of hydrophobic dyes in polystyrene micro- and nanoparticles via swelling procedures
(2011)
Aiming at the derivation of a generalized
procedure for the straightforward preparation of particles
fluorescing in the visible and near-infrared (NIR) spectral
region, different swelling procedures for the loading of the
hydrophobic polarity-probe Nile Red into nano- and
micrometer sized polystyrene particles were studied and
compared with respect to the optical properties of the
resulting particles. The effect of the amount of incorporated
dye on the spectroscopic properties of the particles was
investigated for differently sized beads with different
surface chemistries, i.e., non-functionalized, aminomodified
and PEG-grafted surfaces. Moreover, photostability
and leaking studies were performed. The main criterion
for the optimization of the dye loading procedures was a
high and thermally and photochemically stable fluorescence
output of the particles for the future application of these
systems as fluorescent labels.
The accurate knowledge of the properties of polycapillary X-ray semi-lenses has a significant influence on the quantitative results in a widespread field of applications involving microfocus X-ray beams. A routine procedure for the characterisation of a polycapillary X-ray semi-lens with a scanning electron microscope (SEM) having attached an energy dispersive spectrometer (EDS) is presented in this paper. A key issue of the procedure consists of fitting the semi-lens in front of the EDS for spectra acquisition. Relevant semi-lens parameters such as focal distance, full width at half maximum (FWHM) of the acceptance area, and transmission are determined in parallelising mode of the semi-lens. Special attention has been paid to the calculation of the transmission.
During the mineralisation of metal carbonates MCO3 (M = Ca, Sr, Ba, Mn, Cd, Pb) liquid-like amorphous intermediates emerge. These intermediates that form via a liquid/liquid phase separation behave like a classical emulsion and are stabilized electrostatically. The occurrence of these intermediates is attributed to the formation of highly hydrated networks whose stability is mainly based on weak interactions and the variability of the metal-containing pre-critical clusters. Their existence and compositional freedom are evidenced by electrospray ionization mass spectrometry (ESI-MS). Liquid intermediates in non-classical crystallisation pathways seem to be more common than assumed.
Calibration of two commercially available glow discharge double focusing mass spectrometers, the VG 9000 and Element GD, is described using synthetic pin standards pressed from solution doped copper and zinc matrices. A special pressing die was developed for this purpose and optimal results were obtained with the highest possible pressures, i.e., 95 kN·cm- 2. This calibration approach permits the determination of trace element mass fractions down to µg·kg- 1 with small uncertainties and additionally provides traceability of the GD-MS results in the most direct manner to the SI (International System of Units). Results were validated by concurrent measurements of a number of compact copper and zinc certified reference materials. The impact of the sample pin cross-section (circular or square) was investigated with the use of a new pin-sample holder system for the Element GD. The pin-sample holder was designed by the manufacturer for pin-samples having circular cross-section; however, samples with square pin cross-section were also shown to provide acceptable results. Relative Sensitivity Factors for some 50 analytes in copper (VG 9000, Element GD) and zinc matrices (VG 9000) are presented. The field of applicability of GD-MS may be considerably extended via analysis of pin geometry samples based on their ease of preparation, especially with respect to the accuracy and traceability of the results and the enhanced number of analytes which can be reliably calibrated using such samples.
Abel inversion applied to a transient laser induced plasma: implications from plasma modeling
(2011)
We test the effects of non-uniformity, non-transparency, and non-stationarity of a laser-induced plasma on the results obtained by the Abel inversion method. The method is commonly used for obtaining spatially resolved emissivity of axially symmetric non-homogeneous radiating objects. Besides the axial symmetry, the plasma is assumed to be optically thin. As the method addresses a certain plasma state, the plasma is required to be stationary during measurements. It is difficult to satisfy the aforementioned conditions for transient laser induced plasmas. As such the plasmas are not stationary; they have steep gradients of thermodynamic parameters that rapidly vary during the plasma evolution. Therefore, any conclusion based on time-integrated measurements and the corresponding data processing should account for these effects. In this work, we use the collision-dominated plasma model to generate time- and spatially resolved synthetic spectra. The spectra are processed by executing the Abel inversion using two numerical algorithms. Thus obtained spatially resolved plasma parameters (emissivity, temperature, and number density) are compared with the exact parameters used to set up the model. In doing so, the accuracy of the Abel inversion method is assessed. Special attention is paid to the dynamic aspect of the expanding plasma and possible errors which result from time-integrated measurements.
Determining the influence of impurities on the fixed-point emperatures
of the ITS-90 requires the completion of several tasks. In this paper, the Progress made at Physikalisch-Technische Bundesanstalt (PTB) and BAMFederal Institute for Materials Research and Testing is presented and remaining questions are discussed.
The projected characterization procedure at PTB, which is based on the established SIE method (sum of the individual estimates), using a new indium fixed-point cell is described as an example. This procedure includes an SI-traceable chemical Analysis of the material in the fixed-point cell with sufficiently low uncertainties, the individual experimental determination of the influence of the quantified impurities on the fixed-point temperature, and the establishment of direct links to the phase-transition temperatures of the national standard and of an assumed material of ideal purity.
A characteristic difference to the common practice is the chemical analysis of the fixed-point metal being done after determining the cells freezing temperature. This allows for the detection and consideration of contamination and purification effects due to the filling process, or due to the contact with the carbon crucible and other parts of the fixed-point cell. A chemical analysis of an indium fixed-point was carried out by BAM with relative measurement uncertainties below 30 % which have not been previously achieved. The results provide evidence for the precipitation of some impurities,
which is apparently inconsistent with the corresponding binary phase diagrams, but was explained in a recent publication. Implications for the use of the SIE method shall be described briefly at the end.