Electrochemical half-cell potential measurements for the detection of reinforcement corrosion
(2014)
This specification describes the application of electrochemical half‐cell potential measurements (frequently also called potential mapping) for the detection of reinforcement corrosion in reinforced concrete structures. Areas of corroding reinforcement steel can be located in a nondestructive manner by means of this procedure. Half‐cell potential measurements are used in order to detect chloride‐induced corrosion. However, it is not recommended in order to assess the risk of carbonation‐induced corrosion. For this purpose the determination of the carbonation depth and the concrete cover appear to be more appropriate.
The content of this specification exclusively refers to the application of mobile, local variable reference electrodes, which are only placed on the concrete surface while measuring. The technique distinguishes itself thereby from the range of corrosion monitoring systems with stationary installed reference electrodes and sensor systems, respectively, whereby it is possible to continuously track measurements within the area of the installed electrodes. However, these methods are not dealt with in this specification.
Dieses Merkblatt beschreibt die Anwendung elektrochemischer Potentialmessungen (häufig auch als Potentialfeldmessung bezeichnet) zur Detektion von Bewehrungsstahlkorrosion an Stahlbetonbauwerken. Mit Hilfe dieses Verfahrens können Bereiche korrodierender Bewehrung zerstörungsfrei lokalisiert werden. In der Regel kommt diese Messmethode bei der Detektion chloridinduzierter Korrosion zum Einsatz. In Abgrenzung hierzu sollte die Abschätzung der Gefahr einer karbonatisierungsinduzierten Korrosion durch Bestimmung der Karbonatisierungstiefe und der Betondeckung erfolgen.
Im Zusammenhang mit Planungs- und Entwicklungsaufgaben, den Forderungen in Normen und Regelwerken, in betrieblichen Arbeitsanweisungen, den Vorgaben für Zulieferteile oder bei der Auseinandersetzung mit Schadensfällen stellen sich häufig Fragen zum Korrosionsschutz sowie zu entsprechenden Prüf- und Untersuchungsverfahren. Die daraus gewonnenen Ergebnisse sollen z. B. eine Eignung von Werkstoffen oder Schutzsystemen unter spezifischen Einsatzbedingungen, die Dauerhaftigkeit des Schutzes, den Nachweis einer gleichbleibenden Qualität, die Vergleichbarkeit bekannter mit neuen Korrosionsschutzkonzepten oder den Wirkungsnachweis für gezielte Systemeingriffe belegen. Schnell wird deutlich, dass sich aus dem Blickwinkel verschiedener Branchen ganz unterschiedliche Anforderungsprofile ergeben, die ihren Niederschlag dann in unterschiedlichen Strategien der Prüf- und Untersuchungsverfahren finden.
Die Potentialmessung kann zum Auffinden korrosionsaktiver Bereiche neben Stahlbetonbauwerken auch bei Spannbetonbauwerken angewandt werden, die mit Spannstählen im direkten Verbund hergestellt werden. Bei Vorspannsystemen mit metallischen Hüllrohren im nachträglichen Verbund ist eine Aussage über den Korrosionszustand des Hüllrohrs, nicht aber des Spannstahls möglich. Messungen an Spannbetonbauteilen erfordern grundsätzlich die besonderen Kenntnisse eines Spezialisten.
This specification describes how corrosion monitoring is used to check the condition of reinforced and prestressed concrete members. In this specification, the term "corrosion monitoring" covers all methods in which it is possible to continuously track corrosion-relevant variables in the area of stationary, built-in sensors. This specification does not cover other possible methods, such as potential field measurements, involving the use of mobile, portable sensors that are placed temporarily on the membersurface to take measurements.
The reduction of the chromate contents in cements affects the electrochemical reactions of galvanized reinforcing steels in fresh concrete. By means of electrochemical measurements and bar pull-out tests the effect of chromates on the formation of protective coatings at the zinc and the bond behaviour have been investigated using chromate-containing and chromate-reduced cements. The results have shown that the bond zone was affected as a result of chromate reduction for cement types CEM I and CEM II. The disturbance to the bond zone should be considered as long-term in relation to the pore structure which is formed. The effects on the bond are largely compensated for as the concrete ages. The results of the related bond strength with displacement paths of 0.1 and 0.5?mm, respectively, are still within the range of expected figures for non-galvanized reinforcing steel despite the structural disturbance. Under practical aspects it is not necessary that the existing structural disturbance with respect to bond strength is taken into consideration.
Korrosions- und Verbundverhalten verzinkter Betonstähle in Betonen mit chromatreduzierten Zementen
(2011)
Durch die Absenkung des Chromatgehalts der Zemente verändern sich die elektrochemischen Reaktionen von verzinkten Betonstählen in der Frischbetonphase. Mit Hilfe von elektrochemischen Messungen sowie Stabauszugsversuchen wurde an chromathaltigen und chromatreduzierten Zementen die Auswirkung des Chromats auf die Deckschichtbildung am Zink und auf das Verbundverhalten untersucht.
Mit den Ergebnissen konnte eine Beeinträchtigung der Verbundzone als Folge der Chromatreduzierung für die Zementarten CEM I und CEM II nachgewiesen werden. Die Störung der Verbundzone ist in Bezug auf die sich ausbildende Porenstruktur als dauerhaft anzusehen. Die Auswirkungen auf das Verbundverhalten werden mit zunehmendem Betonalter weitgehend kompensiert. Die Ergebnisse der bezogenen Verbundspannung bei Verschiebewegen von 0,1 mm und 0,5 mm liegen trotz der Gefügestörung noch im Bereich der Erwartungswerte für den unverzinkten Betonstahl. Unter baupraktischen Gesichtspunkten muss die auftretende Gefügestörung hinsichtlich der Verbundspannung daher keine Berücksichtigung finden.