Muon Tomography of the Interior of a Reinforced Concrete Block: First Experimental Proof of Concept
(2021)
Quality assurance and condition assessment of concrete structures is an important topic world-wide due to the aging infrastructure and increasing traffic demands. Common topics include, but are not limited to, localisation of rebar or tendon ducts, geometrical irregularities, cracks, voids, honeycombing or other flaws. Non-destructive techniques such as ultrasound or radar have found regular, successful practical application but sometimes suffer from limited resolution and accuracy, imaging artefacts or restrictions in detecting certain features. Until the 1980s X-ray transmission was used in case of special demands and showed a much better resolution than other NDT techniques. However, due to safety concerns and cost issues, this method is almost never used anymore. Muon tomography has received much attention recently. Novel detectors for cosmic muons and tomographic imaging algorithms have opened up new fields of application, such as the investigation of freight containers. Muon imaging also has the potential to fill some of the gaps currently existing in concrete NDT. As a first step towards practical use and as a proof of concept we used an existing system to image the interior of a reference reinforced 600 kg concrete block. Even with a yet not optimized setup for this kind of investigation, the muon imaging results are at least of similar quality compared to ultrasonic and radar imaging, potentially even better. The data acquisition takes more time and signals contain more noise, but the images allowed to detect the same important features that are visible in conventional high energy X-ray tomography. In our experiment, we have shown that muon imaging has potential for concrete inspection. The next steps include the development of mobile detectors and optimising acquisition and imaging parameters.
This paper presents the progress of successful location of grouting faults in tendon ducts with ultrasonic imaging. The examples were obtained in the research group FOR 384 funded by DFG (German Research Foundation). The co-operation of experimental research and modeling allowed imaging and identification of grouted and ungrouted areas of tendon ducts (including strands) in a large test specimen (40 m²). In addition to the criteria for indicating grouting faults in post-tensioned ducts known until now the phase evaluation of reflected ultrasonic pulses is described. Experiments and modeling of wave propagation are presented for reflections at metal plates in concrete (thickness range 0.5 mm to 40 mm) and for tendon ducts including strands.
The main part of the progress was achieved by automated measurements using dry contact transducers, 3D-SAFT reconstruction including phase evaluation and modeling considering wave propagation for typical elastic parameters and exact experimental site conditions. The results for shear waves as well as for pressure waves are compared in the frequency range from 50 kHz to 120 kHz.