Filtern
Dokumenttyp
- Zeitschriftenartikel (20)
- Posterpräsentation (20)
- Vortrag (15)
- Beitrag zu einem Tagungsband (4)
- Handbuch (1)
- Sonstiges (1)
- Forschungsdatensatz (1)
Sprache
- Englisch (47)
- Deutsch (14)
- Mehrsprachig (1)
Schlagworte
- Process Analytical Technology (21)
- Benchtop-NMR (15)
- NMR spectroscopy (10)
- Prozessanalytik (9)
- qNMR (9)
- Benchtop NMR (8)
- NMR-Spektroskopie (8)
- CONSENS (6)
- Industry 4.0 (4)
- Modular Production (4)
- Modular production (4)
- Online NMR Spectroscopy (4)
- Artificial Neural Networks (3)
- Cyber-Physical Systems (3)
- Interlaboratory Comparison (3)
- Mass Spectrometry (3)
- Metrology (3)
- Nuclear Magnetic Resonance Spectroscopy (3)
- Quantitative NMR Spectroscopy (3)
- AAA (2)
- Amino acid analysis (2)
- Calibration (2)
- Compact NMR Spectroscopy (2)
- ISO 17025 (2)
- Modulare Produktion (2)
- NIR (2)
- NMR Spectroscopy (2)
- Online-NMR-Spektroskopie (2)
- Partial Least Squares Regression (2)
- Process Control (2)
- Process analytical technology (2)
- Protein hydrolysis (2)
- Prozessindustrie (2)
- Quality Control (2)
- Quantitative NMR spectroscopy (2)
- Reference materials (2)
- Silane (2)
- Silanes (2)
- Temperature Control (2)
- Traceability (2)
- AAAA (1)
- Accreditation (1)
- Affinity chromatography (1)
- Antibodies (1)
- Aromatic amino acid analysis (1)
- Artificial neural networks (1)
- Benchtop NMR Spectroscopy (1)
- Benzene-1,3,5-tricarboxylic acid (1)
- Betriebspunktoptimierung (1)
- Biochemistry (1)
- Bisphenol-A (1)
- Bovine serum albumin (BSA) (1)
- Cell studies (1)
- Chemical Process Control (1)
- Chemical Production (1)
- Chemische Prozesskontrolle (1)
- Compact NMR (1)
- Compact NMR spectroscopy (1)
- Compound-independent calibration (1)
- Continuous Manufacturing (1)
- Continuous Processes (1)
- Continuous processes (1)
- Corundum (1)
- Cyber-physical systems (1)
- DFT (1)
- Data Fusion (1)
- Datenanalyse (1)
- Datenkonzepte (1)
- Dendrimer (1)
- Digital Transformation (1)
- Dispersions (1)
- Dye (1)
- Echtzeitoptimierungsverfahren (1)
- Ergot alkaloids (1)
- Esterification (1)
- Extraktion (1)
- Feldintegration (1)
- Field integration (1)
- First Principles (1)
- Flow NMR (1)
- Fluorescence spectroscopy (1)
- General Medicine (1)
- Grignard reaction (1)
- Grignard-Reaktion (1)
- GxP (1)
- Handbook (1)
- Histidine (1)
- Hydrazinolysis (1)
- Hydrochloric acid (1)
- Hydrogenation (1)
- Hydrogenierung (1)
- ISO/IEC 17025 (1)
- IT-OT-Testplattform (1)
- Imidazole (1)
- Indirect Hard Modeling (1)
- Indirect Hard Modelling (1)
- Industry 4.0, (1)
- Inline Analytics (1)
- Interlaboratory key comparison (1)
- Internal standard (1)
- Internal standards (1)
- Iterative real-time optimization (1)
- Kalibriertransfer (1)
- Kompost (1)
- Mass spectrometry (1)
- Messunsicherheit (1)
- Mikroplastik (1)
- Model Predictive Control (1)
- Modifier adaptation (1)
- Modifier-Adaptation (1)
- Molecular Biology (1)
- Multivariat (1)
- Multivariate Data Analysis (1)
- NIR Spectroscopy (1)
- NIST (1)
- NMR Method Validation (1)
- NMR Spektroskopie (1)
- NMR spetroscopy (1)
- Near Infrared Spectroscopy (1)
- Nonspecific binding (NSB) (1)
- Nuclear Magnetic Resonance (1)
- Nuclear magnetic resonance spectroscopy (1)
- Online NMR spectroscopy (1)
- Online-NMR spectroscopy (1)
- PANIC (1)
- PLSR (1)
- Particle synthesis (1)
- Phenylalanine (1)
- Phenylketonuria (1)
- Plant-model mismatch (1)
- Polyglycerol (1)
- Powder X-ray diffraction (1)
- Process Analytical Tecnology (1)
- Process Industry (1)
- Process control (1)
- Process monitoring (1)
- Process-NMR (1)
- Prozess-Steuerung (1)
- Prozesskontrolle (1)
- Purification (1)
- Purity assessment (1)
- QI-Digital (1)
- Quantitative protein analysis (1)
- Quantum Mechanics (1)
- Raman-Spektroskopie (1)
- Reaction Monitoring (1)
- Reactor control (1)
- Real-time process monitoring (1)
- Real-time quality control (1)
- Salicylic acid (1)
- Salts (1)
- Sapphire (1)
- Self-assembled monolayers (SAM) (1)
- Sensor (1)
- Sensors (1)
- Silica and polystyrene nanoparticles (1)
- Smart Sensors (1)
- Soil (1)
- Solid-phase extraction (SPE) (1)
- SsNMR (1)
- Structural Biology (1)
- Sum parameter method (1)
- Terephthalic acid (1)
- Thermostating (1)
- Tryptophan (1)
- Tyrosine (1)
- Uncertainty Evaluation (1)
- ValidNMR (1)
- Validation (1)
- Wasserstofftankstelle (1)
- Weighing Uncertainty (1)
- compost (1)
- pH probe (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (62) (entfernen)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (15)
Global demand for pigments is expected to increase to around 13.4 million tons per year by 2030, representing approximately $22 billion – 5% of which will be azo pigments as the main organic pigments. Azo pigments, i.e., especially the azo bridge required for them, are almost exclusively produced in technology by the so-called azo coupling reaction in large-scale approaches on the scale of 50–100 cubic meters. Among other things, one of the reasons why large-scale production itself is still essentially discontinuous is the lack of analytical methods for a continuous azo pigment synthesis.
In an azo coupling process, an aromatic amine is diazotized to form the diazonium compound (diazo compound), which then reacts with a coupling component, i.e., "couples". A slight excess of the coupler is desired for the end of the reaction, which stoichiometrically consumes the remaining (harmful) diazo compound, i.e., below 500 ppm. This is carried out with a manual spotting reaction of a fast-binding coupler.
To carry out continuous azo coupling, care must be taken to ensure that the actual coupling reaction proceeds as rapidly as possible, i.e., preferentially, compared with possible side reactions. Reliable measuring methods are thus a decisive criterion for the useful performance of a continuous azo pigment synthesis. An analytical online procedure is difficult due to several limitations at once: solid dispersions extremely limit the range of reproducible analytical procedures. In addition, the appearance of a signal (e.g., excess of a starting material) in the ppm range must be reliably detected against the matrix background.
The back-titration method and benchtop NMR spectroscopy were used to overcome these problems. We present a feasibility study for a suitable process analysis with benchtop NMR spectroscopy on disperse systems for equimolar dosing of the "diazotization" or "coupling" sub-step in azo coupling, which was carried out in cooperation with a chemical company. This could replace tedious manual spotting
Near-infrared (NIR) spectroscopy is a promising candidate for low-cost, nondestructive, and high-throughput mass quantification of micro¬plastics in environmental samples. Widespread application of the technique is currently hampered mainly by the low sensitivity of NIR spectroscopy compared to thermo-analytical approaches commonly used for this type of analysis. This study shows how the application of NIR spectroscopy for mass quantification of microplastics can be extended to smaller analyte levels by combining it with a simple and rapid microplastic enrichment protocol. For this purpose, the widely used flotation of microplastics in a NaCl solution, accelerated by centrifugation, was chosen which allowed to remove up to 99 % of the matrix at recovery rates of 83–104 %. The spectroscopic measurements took place directly on the stainless-steel filters used to collect the extracted particles to reduce sample handling to a minimum. Partial least squares regression (PLSR) models were used to identify and quantify the extracted microplastics in the mass range of 1–10 mg. The simple and fast extraction procedure was systematically optimized to meet the requirements for the quantification of microplastics from common PE-, PP-, and PS-based packaging materials with a particle size < 1 mm found in compost or soils with high natural organic matter content (> 10 % determined by loss on ignition). Microplastics could be detected in model samples at a mass fraction of 1 mg g-1. The detectable microplastic mass fraction is about an order of magnitude lower compared to previous studies using NIR spectroscopy without additional enrichment. To emphasize the cost-effectiveness of the method, it was implemented using some of the cheapest and most compact NIR spectrometers available.
Mass Spectrometry (MS) and Nuclear Magnetic Resonance Spectroscopy (NMR) are valuable analytical and quality control methods for most industrial chemical processes as they provide information on the concentrations of individual compounds and by-products. These processes are traditionally carried out manually and by a specialist, which takes a substantial amount of time and prevents their utilization for real-time closed-loop process control. This paper presents recent advances from two projects that use Artificial Neural Networks (ANNs) to address the challenges of automation and performance-efficient realizations of MS and NMR. In the first part, a complete toolchain has been realized to develop simulated spectra and train ANNs to identify compounds in MS. In the second part, a limited number of experimental NMR spectra have been augmented by simulated spectra, to train an ANN with better prediction performance and speed than state-of-the-art analysis. These results suggest that, in the context of the digital transformation of the process industry, we are now on the threshold of a strongly simplified use of MS and MRS and the accompanying data evaluation by machine-supported procedures, and can utilize both methods much wider for reaction and process monitoring or quality control.
Monitoring chemical reactions is the key to chemical process control. Today, mainly optical online methods are applied, which require excessive calibration effort. NMR spectroscopy has a high potential for direct loop process control while exhibiting short set-up times. Compact NMR instruments make NMR spectroscopy accessible in industrial and harsh environ¬ments for advanced process monitoring and control, as demonstrated within the European Union’s Horizon 2020 project CONSENS.
We present a range of approaches for the automated spectra analysis moving from conventional multivariate statistical approach, (i.e., Partial Least Squares Regression) to physically motivated spectral models (i.e., Indirect Hard Modelling and Quantum Mechanical calculations). By using the benefits of traditional qNMR experiments data analysis models can meet the demands of the PAT community (Process Analytical Technology) regarding low calibration effort/calibration free methods, fast adaptions for new reactants or derivatives and robust automation schemes.
Produzieren Sie schon oder kalibrieren Sie noch? – Online-NMR-Spektrometer als Smarte Feldgeräte
(2018)
Der Vortrag zeigt allgemeine Anforderungen an "smarte Feldgeräte" und deren Entwicklung in den vergangenen Jahren. Am Beispiel eines smarten Online-NMR-Sensors, der in einem EU-Projekt von der BAM entwickelt wurde, wird die Umsetzung der Anforderung aufgezeigt. Schließlich werden weitere Technologieanforderungen und Lösungsansätze vorgestellt.
Plastic pollution is the biggest environmental concern of our time. Breakdown products like micro- and nanoplastics inevitably enter the food chain and pose unprecedented health risks. In this scenario, bio-based and biodegradable plastic alternatives have been given a momentum aiming to bridge a transition towards a more sustainable future. Polyhydroxyalkanoates (PHAs) are one of the few thermoplastic polymers synthesized 100 % via biotechnological routes which fully biodegrade in common natural environments. Poly(hydroxybutyrate-cohydroxyhexanoate) [P(HB-co-HHx)] is a PHA copolymer with great potential for the commodity polymers industry, as its mechanical properties can be tailored through fine-tuning of its molar HHx content. We have recently developed a strategy that enables for reliable tailoring of the monomer content of P(HB-co-HHx).
Nevertheless, there is often a lack of comprehensive investigation of the material properties of PHAs to evaluate whether they actually mimic the functionalities of conventional plastics. We present a detailed study of P(HB-co-HHx) copolymers with low to moderate hydroxyhexanoate content to understand how the HHx monomer content influences the thermal and mechanical properties and to link those to their abiotic degradation. By increasing the HHx fractions in the range of 2 – 14 mol%, we impart an extension of the processing window and application range as the melting temperature (Tm) and glass temperature (Tg) of the copolymers decrease from Tm 165 ◦C to 126 ◦C, Tg 4 ◦C to − 5.9 ◦C, accompanied by reduced crystallinity from 54 % to 20 %.
Elongation at break was increased from 5.7 % up to 703 % at 14 mol% HHx content, confirming that the range examined was sufficiently large to obtain ductile and brittle copolymers, while tensile strength was maintained throughout the studied range. Finally, accelerated abiotic degradation was shown to be slowed down with an increasing HHx fraction decreasing from 70 % to 55 % in 12 h.
The application of compact NMR instruments to continuously flowing samples at higher temperatures or exothermically reacting mixtures is limited by the temperature sensitivity of permanent magnets. Typically, such temperature effects directly influence the achievable magnetic field homogeneity and hence measurement quality. The internal-temperature control loop of the magnet and instruments is typically not designed for compensation of such effects. Passive insulation is restricted by the small dimensions within the magnet borehole.
Here, we present a design approach for active heat shielding with the aim of variable temperature control of NMR samples for benchtop NMR instruments using a compressed airstream which is variable in flow and temperature. Based on the system identification and surface temperature measurements using an optical thermo-graphy setup, a model predictive control was set up to minimize any disturbance effect on the permanent magnet from the probe or sample temperature.
This methodology will facilitate the application of variable-temperature shielding and, therefore, potentially extend the application of compact NMR instruments to flowing samples at higher temperature than the permanent magnet.
The application of compact NMR instruments to hot flowing samples or exothermically reacting mixtures is limited by the temperature sensitivity of permanent magnets. Typically, such temperature effects directly influence the achievable magnetic field homogeneity and hence measurement quality. The internal-temperature control loop of the magnet and instruments is not designed for such temperature compensation. Passive insulation is restricted by the small dimensions within the magnet borehole.
Here, we present a design approach for active heat shielding with the aim of variable temperature control of NMR samples for benchtop NMR instruments using a compressed airstream which is variable in flow and temperature. Based on the system identification and surface temperature measurements through thermography, a model predictive control was set up to minimise any disturbance effect on the permanent magnet from the probe or sample temperature.
This methodology will facilitate the application of variable-temperature shielding and, therefore, extend the application of compact NMR instruments to flowing sample temperatures that differ from the magnet temperature.
Um die internationale Spitzenposition deutscher Unternehmen der Prozessindustrie auch in Zukunft sicher zu stellen, müssen die Unternehmen ihre Prozesse und Geschäftsabläufe digitalisieren und gemeinsam mit der Forschung innovative neue Methoden, Apparate, Anlagen, Sensoren und Automatisierungstechnik sowie Datenkonzepte entwickeln. All dies erfordert den Aufbau neuer Fähigkeiten, Investition in Talente, interdisziplinäre Kommunikation zwischen verschiedenen Personen und Abteilungen und eine Bereitschaft zur Veränderung.
The use of benchtop-NMR instruments is constantly increasing during the recent years. Advantages of being affordable, portable and easy-to-operate without the need for trained staff make them especially interesting for industrial applications in quality control. However, applications of NMR spectroscopy as an online PAT tool are still very rare but offer a huge potential for process optimization and control. A key task to exploit this potential is hardware field integration of the lab-instruments in a rough environment of a chemical plant. Additionally, developments in automation and data evaluation are mandatory to ensure a robust unattended operation with low maintenance requirements. Here, we show an approach of a fully automated analyzer enclosure considering explosion safety, field communication, as well as environmental conditions in the field.
Temperature sensitivity is still a limitation of benchtop-NMR instruments in flow applications. Recent developments of manufacturers allow for limited operation at static temperature levels, however, a dynamic system for continuous operation is still not available. Using a prototype system offering a larger bore, active temperature shielding studies with thermostated air were performed evaluating the performance.
Automated data evaluation of NMR spectra using a modular indirect hard modeling (IHM) approach showed good results and flexibility. A second data analysis approach based on artificial neural networks (ANN) was evaluated.Therefore, amount of data was augmented to be sufficient for training. The results show comparable performance, while improving the calculation time tremendously, offering new ways to simultaneously evaluating large numbers of different models.