Filtern
Erscheinungsjahr
Dokumenttyp
Schlagworte
- Active thermography (25) (entfernen)
Organisationseinheit der BAM
As shown recently, the quantification of damage in historic masonry structures is possible by using active thermography. In this paper, a case study is presented concerning systematic studies of the determination of damage size and prognosis of damage increase inside a sandstone column by using different approaches of active thermography. Various heating sources as well as impulse and periodic heating have been compared. Reproducible investigations in regular time intervals for structural monitoring are possible.
Active thermography is sensitive to inhomogeneities at and below the surface of objects investigated. Thus, it should be useful for detecting plaster delaminations on concrete. In this paper, the results of field and laboratory investigations into plaster-covered concrete were compared. For evaluating the bonding state of the plaster it is not sufficient to study only the thermal contrasts at the surface of the investigated objects. The experimental results suggest that the overall thermal behaviour has to be considered.
Impulse and lock-in thermography have been applied to detect delaminations of prototype solder joints, similar to those to be produced between Cu shunts and Cu busbar stabilisers at the Large Hadron Collider (LHC) at CERN. Two infrared cameras with different detector materials and with different spectral ranges and two excitation techniques have been tested and compared for their ability to detect delaminations behind 2 and 3 mm thick Cu shunts. We have analyzed the signal to noise ratio (SNR) for each detected defect and are able to detect defects down to a nominal edge length of 4 mm behind 2 mm thick Cu shunts by using fast impulse thermography and a camera with a microbolometer array. For the 3 mm thick Cu shunt, on the other hand, the nominal 4 mm defect is only visible in the lock-in thermography phase images and the highest SNR has been achieved with a cooled InSb-based camera. In addition, numerical simulations show the influence of the minimum detectable defect size on the shunt thickness and that the developed on-site testing technique is sufficient to find all defects that are detectable theoretically.
Influence of concret properties on the calibration of radar, ultrasonics and active thermography
(2008)
Amongst various other NDT methods, within the EMRP-project
‘VITCEA’ active thermography is validated for testing of CFRP and
GFRP structures constructed for energy application. In this
contribution, the optical and thermal properties of CFRP and GFRP
reference defect artefact (RDA) and natural defects artefact (NDA)
test specimens are characterized. Different excitation techniques
and techniques for data analysis are compared for optimizing the
number of detected defects.
Active thermography is well suited for the detection of delaminations and cracks in façade elements like plaster and tiles. Not only artificial heating but also solar heating can be used if the adjustment of the façade and the weather conditions are suitable. Optical methods like laser scanners, photogrammetric methods and crack tracking sensors are providing geometrical 3D data which can be used for a 3D mapping of thermograms and for providing data with higher geometrical resolution. Thus, by the combination and fusion of these data, a comprehensive mapping and monitoring of damages of façade systems is possible.
Lockin thermography as well as flash thermography are very well suited for non-destructive testing and characterisation of inhomogeneities and damage in CFRP structures. Both methods are applied more and more in research and industry, but until know it is not clear which are the advantages of one method against the other. In
this paper, results of two research projects concerning the validation and standardisation of both methods are presented. Three different types of CFRP test specimens consisting of well-defined flat bottom holes, of artificial delaminations made of PTFE plates embedded in CFRP and of real impact damage have been investigated systematically with flash and lockin excitation. Here, the phase images of both methods are compared qualitatively as well as quantitatively.
Applications of infrared thermography in civil engineering are not limited to the identification of heat losses in building envelopes. Active infrared thermography methods enable structural investigations of building elements with one-sided access up to a depth of about 10 cm. Masonry and especially historical masonry has a very heterogeneous structure containing several different materials (brick, stone, mortar, plaster, wood, metal, etc.) with various thermal properties. As many classes of damage originate from defects that are close to the surface, active thermography is in general very well suited to assessing different test problems in cultural heritage buildings. In this paper, the physical background, equipment, environmental influences and material properties are discussed. Several application results are presented. It is shown how active thermography can be integrated into a holistic approach for the assessment of historical structures.
Impulse thermography is an active method for quantitative investigations of the near
surface region of various structures. It has recently been applied and optimized to applications in civil
engineering. For quantitative analysis of data recorded on the building site, the problems are manifold.
Here, the influence of the different surface properties on the detection and characterization of voids
and honeycombing simulated by polystyrene cubes and cubes prepared of porous concrete are
demonstrated.
Methods for the combination (i. e. comparison and overlay) and data fusion (i. e. integration of all data in one data set, replacement of data) of active thermography and D laser scanner (light section method) have been developed. Systematic investigations for quantification of damage in historic structures are presented using both techniques. A case study shows that reproducible investigations at regular time intervals are very well suited for structural monitoring.
Ever larger high pressure die castings (HPDC) with ever thinner walls raise the issue of casting defects. Properties of components are often strongly influenced by inner porosity. In the case of high pressure die castings, shrinkage and gas porosity occur. Two possibilities of characterizing porosity - by microscopy and acitve thermography - are dealt with in two articles. In the previous article, the microscopic investigations are presented. In this article, first the feasibility of thermographic detection will be discussed based on simulations and, thereafter, the experimental determination of porosity with active thermography will be described.
Die Bewertung des Zustandes und der Haftung von Putz und Fassadenelementen auf den darunterliegenden Bauwerksstrukturen ist eine häufig auftretende Fragestellung bei der Erhaltung und Instandsetzung von Bauwerken und Baudenkmälern. Hier müssen nicht nur wirtschaftliche und denkmalpflegerische, sondern auch sicherheitsrelevante Aspekte berücksichtigt werden. Fehlstellen und Ablösungen können, auch wiederholend, mit hoher Nachweisempfindlichkeit mit aktiven Thermografieverfahren geortet und unter bestimmten Voraussetzungen quantitativ bewertet werden. Dazu wird der zu untersuchende Bereich zunächst kurzzeitig (mehrere Minuten lang) erwärmt und anschließend die Abkühlung mit einer Infrarotkamera aufgezeichnet. Systematische Untersuchungen an Probekörpern mit einer Vielzahl unterschiedlicher Fehlstellen unterhalb von Kalkputz, Fliesen und Klinkerriemchen zeigen, dass die Fehlstellen sowohl mittels künstlicher Erwärmung durch einen Infrarotstrahler als auch mittels natürlicher Erwärmung durch die Sonne detektiert und charakterisiert werden können. ---------------------------------------------------------------------------------------------------------------------------------------
The evaluation of condition and adhesion of plaster and façade elements to the underlying building structure is a common issue in the maintenance and repair of buildings and monuments. Here not only economic and preservation, but also safety relevant aspects have to be considered. Voids and delaminations can be detected repeatedly with high sensitivity using active thermography methods. Under certain conditions, also a quantitative evaluation is possible. The area under investigation has to be heated up for a short time (up to several minutes). Subsequently, the cooling down is recorded using an infrared camera. Systematic studies on test specimens with a variety of defects below lime plaster, tiles and brick tiles show that the defects can be detected and even characterized both by means of artificial heating using an infrared heater, as well as by natural solar heating.
Ever larger high pressure die castings (HPDC) with ever thinner walls raise the issue of castings defects. Properties of components are often strongly influenced by inner porosity. In the case of high pressure die castings, shrinkage and gas porosity occur. Two possibilities of characterizing porosity – by microscopy and active thermography – are dealt with in two articles. In this article, the microscopic investigations are presented. In a second article, first the feasibility of thermographic detection will be discussed based on simulations and, thereafter, the experimental determination of porosity with active thermography will be described.