Filtern
Dokumenttyp
- Posterpräsentation (7)
- Vortrag (2)
- Zeitschriftenartikel (1)
- Dissertation (1)
Sprache
- Englisch (11)
Referierte Publikation
- nein (11) (entfernen)
Schlagworte
- Imaging (6)
- X-ray (4)
- Coded Apertures (3)
- Coded apertures (3)
- Fluorescence (3)
- Spectroscopy (3)
- Synchrotron (3)
- X-ray spectroscopy (3)
- X-ray fluorescence (2)
- Absorption (1)
Organisationseinheit der BAM
- 6 Materialchemie (10)
- 6.3 Strukturanalytik (10)
Eingeladener Vortrag
- nein (2)
X-ray absorption fine structure (XAFS) spectroscopy is a powerful and widely used tool for material characterization. It is non-destructive, element-sensitive and requires no long-range order of the sample, making it suitable for the investigation of amorphous phases. XAFS includes the X-ray absorption near edge structure (XANES) and the extended X-ray absorption fine structure (EXAFS), providing information about the electronical state of the absorbing atom and the spatial order of the neighboring atoms respectively.
Our new approach presented here is derived from the classical dispersive XAFS setup. The aim is to have a scanningless, stable and reproducible setup for applications, in which dynamic processes occur in the second time scale.
A broad polychromatic beam passes through the sample and is dispersed afterwards by a convexly bent Si (111) crystal. All energies are reflected under different angles and thus spatially separated, allowing a position sensitive detector to record a spectrum over the energy range of the incoming beam in a single shot.
Tests of this setup were performed at the BAMline @ BESSY-II (Berlin, Germany) with different metal foils. First in situ measurements comprised the investigation of the early stages of the zinc(II)2-methylimidazolate (ZIF-8) crystallization. This topic of metal-organic-frameworks (MOF) research is of interest for medical applications. Structural changes with a time resolution of 1 s could be followed. The second dimension of the broad beam can be used for a lateral resolution.
A newly developed EXAFS setup is presented. It enables both time- and spatially resolved EXAFS information simul-taneously in a single shot. First tests of this setup were performed at the BAMline @ BESSY-II (Berlin, Germany). A primary broadband beam generated by a filter/X-ray-mirror combination passes through the sample and is then dif-fracted by a convexly bent Si (111) crystal. This results in a divergent beam which is collected by an area sensitive detector, in a θ-2θ-geometry. Beside tests on metal foils the first in situ measurements were successfully carried out. The case-study deals with research on Zn-based Metal-Organic-Frameworks (MOF) with medical/pharmaceutical applications. This hot topic of MOFs research concerns drug delivery and encapsulation of therapeutically relevant proteins (e.g. BSA). Questions like how does a certain protein influences the coordination of Zn can be answered with this new setup. We were able to track structural changes within a 1s time resolution.
Our aim is to develop a new method for full field X ray fluorescence imaging at the BAM line @ BESSY II. We will combine an energydispersive array detector for X rays with a coded aperture to get high resolution images . In coded aperture imaging , an object is projected through a mask , producing many overlapping images on the detector . The first part of the project is to perform raytracing simulations to get realistic data and to develop a reconstruction method that allows to get the Information about the investigated object out of the projected image .
We developed a setup for time- and lateral-resolved X-ray absorption fine structure (XAFS) spectroscopy. A dispersive element is placed behind the sample to investigate. The broadband incoming beam transmits the sample, is then dispersed and finally collected by a position sensitive detector. This allows the recording of a whole X-ray absorption near edge structure (XANES) or extended X-ray absorption fine structure (EXAFS) spectrum in a single shot. The dispersive element is a Si(111) crystal, bent by means of a so called wafer bender, developed in house. Our setup is very flexible, easy to adjust and allows a time resolution down to one second which can be used to follow chemical reactions with dynamics on this time scale.
Our aim is to develop a simple and inexpensive method for full field X-ray fluorescence imaging.We combine an energy-dispersive array detector with a coded aperture to obtain high resolution images. To obtain the information from the recorded image a reconstruction step is necessary. The reconstruction methods we have developed, were tested on simulated data and then applied to experimental data. The first tests were carried out at the BAMline @ BESSY II. This method enables the simultaneous detection of multiple elements, which is important e.g. in the field of catalysis.
One aim of this work was the development of a new setup for time- and laterally resolved XAFS measurements, based on the pronciple of dispersive XAFS. This setup is scanning free, stable, inexpensive, and straightforward to adjust for probing different elements. The second part of this work describes the impelemntation of a method for full-field X-ray fluorescence imaging with coded apertures. Expensive and complicated X-ray otpics, that are usually used for full-field imaging, are replaced with a coded aperture that consists of many pinholes drilled in an X-ray opaque material. Coded apertures are inexpensive to fabricate, energy independent and easy to use. The working principle is the same as with a pinhole camera, but the multiple holes allow a higher photon flux compared to a single pinhole or even a polycalippary optic, thus alowwing the reduction of measurement time.
We developed a new method for full field X-ray fluorescence imaging at the BAMline @ BESSY II. We combined an energy dispersive array detector for X-rays with a coded aperture to get high resolution images.
In coded aperture imaging, an object is projected through a mask, producing many overlapping images on the detector. To get the information about the investigated object out of the projected image, a decoding step is necessary.
The first part of our project was to develop the decoding algorithms. We tested the reported reconstruction with an antimask and compared the results with the performance of self-written reconstruction programs based on an iterative and a genetic algorithm. First tests were performed with raytracing simulations.
The next step was the collection of experimental data at the BAMline @ BESSY II (HZB). A test objects could be successfully reconstructed with our newly developed algorithm.
Our aim is to develop a new simple and inexpensive method for full field X-ray fluorescence imaging. We combine an energy-dispersive array detector with a coded aperture. To obtain the information from the recorded image, a reconstruction step is necessary. First tests were carried out at the BAMline at BESSY II. This method enables the simultaneous detection of multiple elements, which is important e.g. in the field of catalysis.
Our aim is to develop a new simple and inexpensive method for full field X-ray fluorescence imaging . We combine an energy dispersive array detector with a coded aperture to obtain high resolution images . To obtain the information from the recorded image a reconstruction step is necessary . The reconstruction methods we have developed , were tested on simulated data and then applied to experimental data . The first tests were carried out at the BAM line @ BESSY II. This method enables the simultaneous detection of multiple elements , which is important e.g. in the field of catalysis.
X-ray fluorescence imaging is a well-established tool in materials characterization. In this work, we present the adaption of coded aperture imaging to full-field X-ray fluorescence imaging at the synchrotron. Coded aperture imaging has its origins in astrophysics, and has several advantages: Coded apertures are relatively easy to fabricate, achromatic, allow a high photon throughput, and high angular acceptance. Coded aperture imaging is a two-step-process, consisting of the measurement process and a reconstruction step. Different programs have been written, for the raytracing/forward projection and the reconstruction. Experiments with coded aperture in combination with a Color X-ray Camera and an energy-dispersive area detector, have been conducted at the BAMline. Measured samples were successfully reconstructed, and gave a 9.1-fold increase in count rate compared to a polycapillary optic.