Filtern
Erscheinungsjahr
- 2012 (17) (entfernen)
Dokumenttyp
- Beitrag zu einem Tagungsband (8)
- Vortrag (5)
- Zeitschriftenartikel (4)
Schlagworte
- Brillouin scattering (4)
- Distributed sensor (3)
- Fiber optic sensor (3)
- Geotextiles (2)
- Nonlinear optics (2)
- OTDR (2)
- POF OTDR (2)
- POF sensor (2)
- Polymer optical fiber (2)
- Polymer optical fibers (POF) (2)
Eingeladener Vortrag
- nein (5)
For patients under Magnetic Resonance Imaging (MRI) spontaneous respiration is constantly at risk of being impaired by anesthetic drugs or by upper airway obstruction. Therefore, continuous monitoring of the breathing activity is needed to assess adequate ventilation or to detect specific obstruction patterns. The paper describes three MRI compatible respiration sensors based on pure optical technologies developed within the EU FP6 project OFSETH. The sensors are based on fiber Bragg gratings, optical time-domain reflectometry and macrobending effects. The developed smart medical textiles can sense elongation up to 3% while maintaining the stretching properties of the textile substrates for patient's comfort. The OFSETH harness allows a continuous measurement of abdominal and thoracic respiration movement while all vitals organs are free for medical staff actions. The sensors were tested in MRI environment and on healthy adults.
We characterize the Brillouin gain spectra (BGS) in perfluorinated graded-index polymer optical fibers (PFGI-POFs) at 1.32 µm and 1.55 µm. Three kinds of PFGI-POFs with the same core diameter, but which are fabricated by different manufacturers, are tested. For all the PFGI-POFs, the Stokes power measured at 1.32 µm is higher than that at 1.55 µm due to the lower propagation loss, but significant differences in Stokes power are observed among the three. Based on the measurement obtained by the optical time-domain reflectometry, we show that the actual propagation loss of the PFGI-POFs plays a crucial role in observing BGS.
Structural health monitoring by distributed fiber optic sensors embedded into technical textiles
(2012)
Technical textiles with embedded distributed fiber optic sensors have been developed for the purposes of structural health monitoring in geotechnical and civil engineering. The distributed fiber optic sensors are based on Brillouin scattering in silica optical fibers and OTDR in polymer optical fibers. Such 'smart' technical textiles are used for reinforcement of geotechnical and masonry structures. The embedded fiber optic sensors provide online information about the condition of the structure and about the occurrence and location of any damage or degradation.--------------------------------------------------------------------------------------------------------------------------------------------------------
Technische Textilien mit integrierten faseroptischen Sensoren eröffnen neue Möglichkeiten der Zustandsüberwachung (structural health monitoring) in Geotechnik und Ingenieurbau. Die verteilt messenden Sensoren basieren auf der Brillouin-Streuung in Glasfasern und auf der OTDR in polymeroptischen Fasern. Derartige 'intelligente' technische Textilien werden in erster Line zur Verstärkung von geotechnischen Bauwerken und von Gebäuden genutzt. Die integrierten Sensoren liefern eine zeitnahe Information über den bestimmungsgemäßen Zustand des Bauwerks sowie über die Entstehung und den Ort von lokalen Bauwerksschäden.
Application results of a dynamic technique for simultaneous measurement of length changes and optical power changes between multiple reflection points in an optical fiber are presented. The technique is based on incoherent optical frequency domain reflectometry (I-OFDR) and allows for measuring for example length changes and optical power changes quasi-distributed at repetition rates up to 2 kHz. Precise measurement with length change resolutions in the µm-range can be conducted using standard single-mode or multi-mode fibers. Previous results of dynamic refractive index change measurement and the use of polymer optical fibers for high-strain measurement are concluded and possible sources of measurement inaccuracies are discussed. Field test results with sensors installed on a masonry building during a seismic shake test are presented. The versatility and simplicity of this technique makes it potentially interesting for application in the structural health monitoring sector and chemical process control.