There is growing interest in quantifying microplastics in environmental samples. This application note presents a thermal extraction desorption-gas chromatography/mass spectrometry (TED-GC/MS) method that is well suited to automation and increased sample throughput. The method is also able to detect all particle sizes in the sample as long as the limit of detection (LOD) is reached and allows analysis of larger samples of 15 to 25 mg or more. Samples were decomposed by thermogravimetric analysis (TGA), and the gaseous decomposition products were trapped on a solid-phase sorbent, followed by thermal desorption‑gas chromatography/mass spectrometry (TD-GC/MS) using an Agilent 5977B GC/MSD coupled to an Agilent 7890B GC. Target microplastic particle (MP) polymers were identified in environmental samples including surface water, finished compost, house dust, and drinking water. Quantification of MP polymers in environmental samples provided LODs of 0.06 to 2.2 μg, allowing the detection of MPs in trace amounts with sample weights of up to 1 g. Method repeatability was adequate for reliable quantification with RSDs of approximately 6 to 12%.
As global demand for polymer products increases, so does the potential amount of leakage into the environment, known as macroplastic (> 1,000 µm) and microplastic particles (MP, 1 - 1,000 µm). To date, the environmental and health consequences are unclear and unpredictable, so robust MP monitoring data are needed to identify the sources, pathways and fate of these particles. Therefore, we developed the thermoanalytical method TED-GC/MS (thermal extraction desorption - gas chromatography/mass spectrometry), which uses polymer-specific thermal decomposition products for the detection of MP in environmental samples. It allows fast identification and the determination of MP mass contents, which is crucial for assessing of their potential effects and thus for legislation and monitoring.
For a better understanding of the TED-GC/MS, this presentation will provide the first methodological insights into systematic assessments of TED-GC/MS performance for MP detection in different environmental model matrices. Results of MP determination from real samples will underline the presentation and aspects of practical application will be addressed.
To harmonise the method, it is essential to assess different analytical performance parameters (e.g. recovery, signal quality or limit of detection, LOD) to ensure comparability of data. For this purpose, standard addition of different aquatic (e.g. suspended particulate matter, limnic sediment, activated sludge) and terrestrial samples (e.g. agricultural soil) were performed with non-biodegradable standard polymers (polyethylene, PE; polyethylene terephthalate, PET; polypropylene, PP; polymethyl methacrylate, PMMA; polystyrene, PS; styrene-butadiene rubber, SBR) as well as biodegradable polymers (polybutylene adipate terephthalate PBAT; polylactide, PLA) and analysed by TED-GC/MS. These results were then compared with the measurements of the neat polymers without matrix.
Mit dem stetigen weltweiten Anstieg der Nachfrage nach Polymerprodukten nimmt auch die potenzielle Menge an Kunststoffabfällen in der Umwelt zu. Problematisch ist, dass viele der wirtschaftlich relevantesten Kunststoffe sehr lange brauchen, um in der Umwelt abzubauen, sich dort akkumulieren und in kritisch betrachtetes Makro- und Mikroplastik zu zerfallen. Auf der Grundlage des Vorsorgeprinzips fordert die Europäische Kommission daher die Entwicklung neuer polymerer Materialien, die diesem Problem der Persistenz entgegenwirken und unter natürlichen Umweltbedingungen schneller abgebaut werden können. 1,2
Um dieses Problem anzusprechen, wurden mittels additiver Fertigung Polymerblends aus photooxidationsempfindlichem Polystyrol (PS) und hydrolyseempfindlicher Polymilchsäure (PLA) hergestellt. Die Hypothese war, dass sich die beiden Thermoplaste aufgrund ihrer unterschiedlichen Abbauprozesse gegenseitig in ihrem Abbau unterstützen, wenn sie unter moderaten, realitätsnahen Umweltalterungsbedingungen (45 °C) abwechselnd der Photooxidation und Hydrolyse ausgesetzt werden.
In der Praxis zeigten die Ergebnisse, dass die Degradation von PLA durch die Anwesenheit von PS deutlich beschleunigt worden ist – wohingegen die Degradation von PS gehemmt wurde. In diesem Vortrag werden die detaillierten Ergebnisse der Oberflächen- (ATR-FTIR, REM) und Bulk-Analysen (DSC, TGA, FTIR-Transmission, TED-GC/MS) der Blends sowie ergänzende Mikroplastik-Ergebnisse des umgebenden Wassermediums (TED-GC/MS) erörtert.
A fast method for microplastic detection is thermal extraction desorption‐gas chromatography/mass spectrometry (TED‐GC/MS), which uses polymer‐specific thermal decomposition products as marker compounds to determine polymer mass contents in environmental samples. So far, matrix impacts of different environmental matrices on TED‐GC/MS performance had not yet been assessed systematically. Therefore, three solid freshwater matrices representing different aquatic bodies with varying organic matter contents were spiked with a total of eight polymers. Additionally, for the first time, the two biodegradable polymers polybutylene adipate terephthalate (PBAT) and polylactide (PLA) were analysed using TED‐GC/MS. The methodological focus of this work was on detectability, quality of signal formation as well as realisation of quantification procedures and determination of the limit of detection (LOD) values. Overall, TED‐GC/MS allowed the unambiguous detection of the environmentally most relevant polymers analysed, even at low mass contents: 0.02 wt% for polystyrene (PS), 0.04 wt% for the tyre component styrene butadiene rubber (SBR) and 0.2 wt% for polypropylene (PP), polyethylene (PE) and PBAT. Further, all obtained LOD values were increased in all matrices compared to the neat polymer without matrix. The LOD of the standard polymers were increased similarly (PS: 0.21–0.34 μg, SBR: 0.27–0.38 μg, PP: 0.32–0.36 μg, PMMA: 0.64–1.30 μg, PET: 0.90–1.37 μg, PE: 3.80–6.99 μg) and their decompositions by radical scission processes were not significantly influenced by the matrices. In contrast, matrixspecific LOD increases of both biodegradable polymers PBAT (LOD: 1.41–7.18 μg) and PLA (0.84–20.46 μg) were observed, probably due to their hetero‐functional character and interactions with the matrices. In conclusion, the TED‐GC/MS performance is not solely determined by the type of the polymers but also by the composition of the matrix.
Following the recommendation of the European Chemicals Agency, on 25 September 2023 the European Commission passed a comprehensive new regulation to reduce emissions of microplastics (MP) into the environment, which includes the sale and use of intentionally added MP.1,2 This also applies to the application of synthetic rubber granulate infill in artificial turf systems and will ultimately have an impact on recreational sports. In Germany, rubber granulate made of ethylene-propylene-diene-monomer rubber (EPDM) is currently predominantly used. So far, there is no sufficient database for estimating MP emissions from artificial turf pitches into the environment and thus their relevance as a source of MP pollution.3 This topic is controversially discussed due to the complexity of sampling and analytics. To close this research gap, this project has the goal to determine mass balances for the emissions of MP from artificial turf pitches to allow an estimation of the amount of MP released per artificial turf pitch and year.
Within this study, MP emissions of three artificial turf scenarios at different time states (unaged, artificially aged and real-time aged) are compared: the past (old turf: fossil based, synthetic infill), present (most commonly installed in Europe: fossil based, EPDM infill), and the future (turf with recycled gras fibres, no synthetic infill). To simulate the outdoor weathering during the lifespan of an artificial turf of approx. 15 years, brand-new artificial turf and EPDM rubber granulate were accelerated aged by means of UV weathering and mechanical stress. Potential MP emissions into surface and groundwater are simulated by lysimeter and shake experiments. MP mass contents are subsequently determined by Thermal Extraction Desorption Gas Chromatography/Mass Spectrometry. Using special microfilter crucibles allows the estimation of the particle sizes of the emitted MP, which is a fundamental requirement for an assessment of potential health hazards for humans.