Building stones are porous media and they can deteriorate through moisture ingress and secondary damage such as crystallization of soluble salts. Not only is this due to the increasing number of flood events in the past years but also structural damages of houses from activity such as leakage or rising moisture (groundwater) are the main causes. The potential benefit of several nondestructive testing methods to assess water damage in building stone has been studied in a field-scale experiment. Three testing walls made of fired clay brick, sandstone, and spongilite were flooded and their drying behavior monitored using infrared thermography, complex resistivity, ground penetrating radar, and ultrasonics. The results were compared to the average moisture content determined by gravimetric weighing of the specimens. Qualitatively, the results of the different nondestructive testing methods matched well. But in terms of quantitative data, some scatter was observed and the results should be viewed with care. Collecting time-consuming calibration data would help to overcome this problem, but especially when dealing with historic building structures, this is not always possible in practice.
Muon Tomography of the Interior of a Reinforced Concrete Block: First Experimental Proof of Concept
(2021)
Quality assurance and condition assessment of concrete structures is an important topic world-wide due to the aging infrastructure and increasing traffic demands. Common topics include, but are not limited to, localisation of rebar or tendon ducts, geometrical irregularities, cracks, voids, honeycombing or other flaws. Non-destructive techniques such as ultrasound or radar have found regular, successful practical application but sometimes suffer from limited resolution and accuracy, imaging artefacts or restrictions in detecting certain features. Until the 1980s X-ray transmission was used in case of special demands and showed a much better resolution than other NDT techniques. However, due to safety concerns and cost issues, this method is almost never used anymore. Muon tomography has received much attention recently. Novel detectors for cosmic muons and tomographic imaging algorithms have opened up new fields of application, such as the investigation of freight containers. Muon imaging also has the potential to fill some of the gaps currently existing in concrete NDT. As a first step towards practical use and as a proof of concept we used an existing system to image the interior of a reference reinforced 600 kg concrete block. Even with a yet not optimized setup for this kind of investigation, the muon imaging results are at least of similar quality compared to ultrasonic and radar imaging, potentially even better. The data acquisition takes more time and signals contain more noise, but the images allowed to detect the same important features that are visible in conventional high energy X-ray tomography. In our experiment, we have shown that muon imaging has potential for concrete inspection. The next steps include the development of mobile detectors and optimising acquisition and imaging parameters.