Correctly modeling the continuous photon spectrum of X-ray tubes requires detailed knowledge of the probability distribution of electron properties at the time of X-ray photon creation, in particular electron energy, depth within the target, and direction of movement. Semi-analytical X-ray spectrum models frequently assume a very simplified or even uniform distribution of electron direction. In the case of thick targets and small deviations from normal incidence this is a useful approximation. For thin targets or large deviations from normal incidence the correct distribution of electron directions becomes more important. As calculation speed is an important aspect of semi-analytical models compared to Monte Carlo simulations, fast evaluation of the distribution of electron properties is highly desirable. The approach presented here numerically evaluates the evolution of a discrete probability distribution of electron properties due to single electron scatter interactions within a plane target. This allows capturing the important aspects of the electron distribution while achieving runtimes of a few seconds up to a minute on a standard office PC.
Radiography benchmark 2014
(2015)
The purpose of the 2014 WFNDEC RT benchmark study was to compare predictions of various models of radiographic techniques, in particular those that predict the contribution of scattered radiation. All calculations were carried out for homogenous materials and a mono-energetic X-ray point source in the energy range between 100 keV and 10 MeV. The calculations were to include the best physics approach available considering electron binding effects. Secondary effects like X-ray fluorescence and bremsstrahlung production were to be taken into account if possible. The problem to be considered had two parts. Part I examined the spectrum and the spatial distribution of radiation behind a single iron plate. Part II considered two equally sized plates, made of iron and aluminum respectively, only evaluating the spatial distribution. Here we present the results of above benchmark study, comparing them to MCNP as the assumed reference model. The possible origins of the observed deviations are discussed.
Modelling becomes more and more important in modern NDE. It is increasingly used to optimize techniques for complex applications and to support the preparation of written procedures. Hence, computer simulation nowadays has to be able to handle all significant properties of an NDE system with sufficient accuracy. In case of radiographic applications this includes models of the radiation source, of the interaction of radiation with materials, of the detection process, and the geometrical description of the part or the construction. Depending on the given inspection problem and the influencing factors that should be addressed by the simulation an appropriate physical model has to be chosen to describe the underlying interaction mechanisms. The simulator aRTist combines analytical and Monte Carlo methods to efficiently model the radiation transport. Simulation is a powerful tool to separate different influencing factors. Here we focus on Monte-Carlo simulation of scatter contributions within aRTist.