Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (25)
- Zeitschriftenartikel (9)
- Vortrag (6)
- Buchkapitel (1)
- Dissertation (1)
- Posterpräsentation (1)
Schlagworte
- Structural Health Monitoring (8)
- Impact (5)
- Damage characterization (4)
- Damage localization (4)
- Model interpolation (4)
- Planar tomography (4)
- Structural health monitoring (4)
- Compressive strength (3)
- DUCON® (3)
- Damage detection (3)
- Ductility (3)
- E-modulus (3)
- Load vector (3)
- Micro-reinforcement (3)
- Mobile elements (3)
- Numerical modeling (3)
- Quasi-static and dynamic tests (3)
- Reinforced concrete structure (3)
- Statistical evaluation (3)
- Statistical tests (3)
- Stereo photogrammetry (3)
- Temperature rejection (3)
- UHPC (3)
- Ansys Autodyn (2)
- Belastungsversuch (2)
- Cable failure (2)
- Cable-stayed bridge (2)
- Crack detection (2)
- Drucker-Prager (2)
- Fatigue (2)
- Fault detection (2)
- Großer Fallturm Horstwalde (2)
- Linear parameter varying systems (2)
- Luminescence (2)
- Modalanalyse (2)
- Numeric simulation (2)
- Offshore-Windenergieanlagen (2)
- Post-impact evaluation (2)
- SDDLV (2)
- Schadensdetektion (2)
- Schwingungsbasierte Verfahren (2)
- Schwingungsdynamik (2)
- Subspace methods (2)
- Subspace-based method (2)
- Subspace-based residual (2)
- Tomographic damage evaluation (2)
- Unterraummethoden (2)
- 3D imaging (1)
- Ambient excitation (1)
- Artificial Intelligence (1)
- Artificial intelligence (1)
- Asymptotic local approach (1)
- BIM (1)
- Bauwerksüberwachung (1)
- Brücke (1)
- Brücken (1)
- Changing process noise (1)
- Climate chamber (1)
- Coating (1)
- Computer Vision (1)
- Crack (1)
- Crack Luminescence (1)
- Crack damage detection (1)
- Detection (1)
- Digital Models (1)
- Drop Tests (1)
- Drop tower (1)
- Environmental changes (1)
- Ermüdungsschäden (1)
- Fallturm (1)
- Faseroptik (1)
- Fatigue damage (1)
- Fault detectionchanging (1)
- Finite Elemente Simulation (1)
- Global ambient vibrations (1)
- Hard impact (1)
- Harter Anprall an Stahlbetonstrukturen (1)
- Impact damage of reinforced concrete (1)
- Impact damage on reinforced concrete (1)
- Impakt (1)
- Laboratory beam structure (1)
- Laminography (1)
- Merkblatt (1)
- Monitoring (1)
- Multiple impact (1)
- Nelson’s method (1)
- Non-Destructive Evaluation (1)
- Numerical damage simulation (1)
- Numerical simulation of impact damage (1)
- Offshore wind energy (1)
- Probability of Detection (1)
- Probability of detection (1)
- Process noise (1)
- Prädiktive Instandhaltung (1)
- Radar (1)
- Reinforced concrete (1)
- Reliability (1)
- Research data management (1)
- Residual evaluation (1)
- Richtlinie (1)
- Risslumineszenz (1)
- SHM (1)
- SHM environmental bridges (1)
- Schadensüberwachung (1)
- Schwingungsmonitoring (1)
- Sensitivity vectors (1)
- Soft impact (1)
- Statistical method (1)
- Steel structures (1)
- Stress stiffening (1)
- System Identification (1)
- Temperature effect rejection (1)
- Temperature effects (1)
- Temperature modeling (1)
- Umwelteinflüsse (1)
- Uncertainty (1)
- Uncertainty in reference (1)
- Uncertainty quantification (1)
- Vibration (1)
- Vibration measurement (1)
- Vibration measurements (1)
- Vibrations (1)
- Wind (1)
- Windenergieanlagen (1)
- building information modelling (1)
- structural health monitoring (1)
- structural integrity management (1)
- support structures (1)
- temperature (1)
Organisationseinheit der BAM
- 7.2 Ingenieurbau (43) (entfernen)
Eingeladener Vortrag
- nein (6)
The new crack luminescence method offers the possibility of making fatigue surface cracks in metallic materials more visible during inspections through a special coating system. This coating system consists of two layers, whereby the first layer has fluorescent properties and emits visible light as soon as it is irradiated by UV light. The top layer is black and is designed to prevent the fluorescent layer from emitting if no crack develops in the underlying material. The technique proved particularly useful in a wide variety of fatigue tests of steel components under laboratory conditions. Moreover, it has the potential to be used in various industrial applications. To enable industrial deployment and integration into maintenance strategies, a concept study is developed in this contribution, resulting in a qualification framework that can serve as a foundation for determining the reliability of the crack luminescence system in terms of a probability of detection curve. Within this study, factors causing measurement variability and uncertainty are being determined and their influences assessed. Due to the extension of the system by a moving computer vision system for automated crack detection using artificial intelligence, additional long-term effects associated with structural health monitoring systems need to be incorporated into an extended probability of detection study as part of the technical justification. Finally, important aspects and findings related to design of experiments are discussed, and a framework for reliability assessment of a new optical crack monitoring method is presented, emphasizing the influence of various uncertainty parameters, including long-term effects such as system ageing.
Support structures of wind turbines in German offshore wind farms are regularly inspected. Currently, inspection outcomes are generally not systematically recorded. This prevents their consistent handling and processing, which is a key requirement to enable an efficient structural integrity management. As part of the DiMoWind-Inspect project, a data model and reference designation system for such inspection results is developed to facilitate their identification, localization, quantification, tracing and linking throughout the lifetime of a wind farm and beyond. The inspection results together with structural health monitoring results and information on repairs form the basis for assessing and predicting the structural condition, estimating the remaining lifetime, and planning of future inspections, structural health monitoring, and repairs. As a basis for developing a digital structural integrity management, a generic framework is proposed in this paper, which describes the stakeholders, data, models, processes and workflows of the integrity management of support structures in offshore wind farms and their interrelations. The framework adopts a building information modelling approach to describe the information relevant to the structural integrity management. The central digital space of the framework is a common data environment. An implementation of the framework will enable a digital structural integrity management in which inspection, structural health monitoring, repair, assessment and planning outcomes generated throughout the life cycle of a wind farm can be consistently collected, managed, shared and processed by the relevant shareholders.
Right from the beginning of applying SHM to bridge structures it was obvious that environmental based perturbations on the measurement significantly influence the ability to identify structural damage.
Strategies are needed to classify such effects and consider them appropriately in SHM. Various methods have been developed and analyzed to separate environmental based effects from damage induced changes in the measures. Generally, two main approaches have emerged from research activity in this fields: (a) statistics based tools analyzing patterns in the data or in computed parameters and (b) methods, utilizing the structural model of the bridge taking into account environmental as well as damage based changes of stiffness values.
With the back-ground of increasing affordability of sensing and computing technology, effort should be made to increase sensitivity, reliability and robustness of procedures, separating environmental from damage caused changes in SHM measures. The contribution describes both general strategies and points out their Advantages and drawbacks. As basis, a review on relevant methods was conducted. The aim of the study is to classify approaches for separating damage describing information from environmental based perturbations in dependency of the SHM objective. And such, it is intended to describe a best practice in designing concepts for Monitoring infrastructure, naturally effected by environmental influences.
The local asymptotic approach is promising for vibration-based fault diagnosis when associated to a subspace-based residual function and efficient hypothesis testing tools. It has the ability of detecting small changes in some chosen system parameters. In the residual function,the left null space of the observability matrix associated to a reference model is confronted to the Hankel matrix of output covariances estimated from test data. When this left null space is not perfectly known from a model, it should be replaced by an estimate from data to avoid model errors in the residual computation. In this paper, the asymptotic distribution of the resulting data-driven residual is analyzed and its covariance is estimated, which includes also the covariance related to the reference null space estimate. The advantages of the data-driven residual are demonstrated in a numerical study, and the importance of including the covariance of the reference null space estimate is shown, which increases the detection Performance.
At present, to produce renewable energy offshore wind farms play an important role. The available space combined with the more valuable wind conditions make offshore locations very attractive for wind powered energy production. In Europe a significant number of offshore wind farms already exist, especially in the North and Baltic Sea. In future this trend will continue, and further offshore wind farms will be built. The majority of offshore wind turbines are mounted on steel foundation structures. Due to the high-cyclic loading by wind and waves fatigue stress plays a substantial role regarding structural safety.
Besides the consideration of fatigue within the design process, to monitor existing steel structures for potential fatigue cracks during their life time is a major topic and a challenge.
For the structures of the offshore wind turbines are large and partially under water effective reliable methods for the detection of fatigue cracks are required.
This contribution presents investigations on different crack detection methods applied at high-cycle fatigue tests on small-scale welded steel samples as well as on large-scale welded steel components. The tests were conducted at the BAM laboratories. For crack detection mainly three different methods were used and compared. The first method regards to the measurement of strain by conventionally strain gauges. Secondly, the crack luminescence was used as a new and effective optical method for surface monitoring. And finally, crack detection by pressure differentials of the inner and outer section of tubular steel elements was investigated. A comparison study will emphasize the advantages and disadvantages of the different methods and show which of the described methods is potentially more suitable for an application on real offshore wind structures.
In structural parts under vibrational loading fatigue cracks can initiate and grow, which can lead to structural failure. Conventional non-destructive testing methods for crack detection provide just a snapshot of fatigue crack evolution, whereas crack luminescence coating realizes clear visibility of the entire crack formation. Fatigue causing cyclic tensile tests and examinations on special test bodies allowing control of the crack opening width demonstrate a high sensitivity of the coating.
We examine the behavior of reinforced concrete components subjected to impact induced loading conditions which might be caused by vessels collisions such as aircraft fuel tanks The concrete plates were impact damaged at TU Dresden and shipped to BAM At BAM laminar tomography as the imaging method is used to determine and quantify the damage state An automatic crack detection method based on template matching is applied to find the cracks and we aim to develop a new method using machine learning Algorithms In addition numerical models are developed to understand the experiment and to predict the damage structures based on failure mechanisms.
Messtechnische Systeme zur Dauerüberwachung von Bauwerken ermöglichen Einblicke in deren reale Trag- und Verformungsverhalten. Die Planung und technische Umsetzung solcher Maßnahmen erfordern für die erfolgreiche Erfüllung der Aufgabenstellungen eine hohe Fachkompetenz, sowohl auf der planerischen Seite, als auch für die fachliche Bewertung von angebotenen Monitoringlösungen. Als Hilfestellung dafür wurde von der Deutschen Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) das Merkblatt „Dauerüberwachung von Ingenieurbauwerken“ erarbeitet, welches nun verfügbar ist. In diesem Beitrag werden die Inhalte des neuen Merkblatts vorgestellt und dieses in die vorhandene Literatur eingeordnet.
Structural health monitoring is a promising technology to automatically detect structural changes based on permanently installed sensors. Vibration-based methods that evaluate the global system response to ambient excitation are suited to diagnose changes in boundary conditions, i.e., changes in member prestress or imposed displacements. In this paper, these changes are evaluated based on sensitivity-based statistical tests, which are capable of detecting and localizing parametric structural changes. The main contribution is the analytical calculation of sensitivity vectors for changes in boundary conditions (i.e., changes in prestress or support conditions) based on stress stiffening, and the combination with a numerically efficient algorithm, i.e., Nelson’s method. One of the main advantages of the employed damage diagnosis algorithm is that, although it uses physical models for damage detection, it considers the uncertainty in the data-driven features, which enables a reliabilitybased approach to determine the probability of detection. Moreover, the algorithm can be trained and the probability of detecting future damages can be predicted based on data and a model from the undamaged structure,
in an unsupervised learning mode, making it particularly relevant for unique structures, where no data from the damaged state is available. For proof of concept, a numerical case study is presented. The study assesses the loss of prestress in a two-span reinforced concrete beam and showcases suitable validation approaches for the sensitivity calculation.
The contribution discusses the processing and analysis of data generated on two different ways of investigations for impact damage in reinforced concrete structures. Damage investigations are essential to determine type and characteristics of damage and thus the residual capacity. Damage describing data is generated using two different types of investigation, a non-destructive tomographic as well as numerical examination. Subsequently, data of both sources was merged and analysed. Within the research project “Behaviour of structural components during impact load conditions caused by aircraft fuel tank collision” reinforces concrete plates were damaged by impact loading, see Hering (2020). Afterwards the damaged specimens were investigated tomographically as well as numerically using several methods and models. Aim of the presented research work was to specify an objective comparability of numerical data with experimentally determined damage patterns and based on this, to establish a quantitative damage evaluation.