Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (42)
- Beitrag zu einem Sammelband (30)
- Beitrag zu einem Tagungsband (28)
- Vortrag (8)
- Sonstiges (7)
- Posterpräsentation (3)
- Buchkapitel (1)
Sprache
- Englisch (119) (entfernen)
Schlagworte
- Computed tomography (22)
- X-ray refraction (18)
- Reconstruction algorithm (8)
- Synchrotron radiation (6)
- Composites (5)
- Electron tomography (5)
- Refraction (5)
- Computed Tomography (4)
- Diffuse background (4)
- Fluorescent screen (4)
- Phase contrast (4)
- Pore size (4)
- Porous ceramics (4)
- Radiography (4)
- Synchrotron (4)
- Tomography (4)
- X-ray refraction topography (4)
- Aerospace (3)
- Ceramics (3)
- Iterative reconstruction (3)
- NDE (3)
- Neutron tomography (3)
- Non-destructive testing (3)
- Pore orientation (3)
- Porosity (3)
- Soft matter radiography (3)
- Synchrotron Radiation (3)
- WAXS (3)
- X-ray (3)
- X-ray Refraction (3)
- X-ray detector backlighting (3)
- X-ray tomography (3)
- X-ray topography (3)
- BAMline (2)
- Bragg magnification (2)
- Cartilage (2)
- Catalyst (2)
- Characterization (2)
- Computed Tomography (CT) (2)
- DEI (2)
- DIRECTT (2)
- Diesel particulate filters (2)
- Diffraction Enhanced Imaging (DEI) (2)
- Diffraction enhanced imaging (2)
- Edge artefact (2)
- Explosives (2)
- Foams (2)
- Focal smearing (2)
- Fuel cell (2)
- Gas diffusion layer (GDL) (2)
- Grating interferometry (2)
- Huygens elementary waves (2)
- Lightweight Materials (2)
- Lightweight materials (2)
- MMC (2)
- Magnetic domains (2)
- Metal Matrix Composites (MMC) (2)
- Metal matrix composites (2)
- Missing wedge (2)
- Neutron imaging (2)
- Neutronen-Tomographie (2)
- Non-Destructive Inspection (NDI) (2)
- PEM fuel cell (2)
- Refraction topography (2)
- Spatial resolution (2)
- Specific surface (2)
- Synchrotron Refraction CT (2)
- Synchrotron refraction computed tomography (2)
- Ti-MMC (2)
- Tomographische Rekonstruktionsalgorithmen (2)
- Topography (2)
- Water management (2)
- X-Ray Refraction (2)
- X-ray compton scattering (2)
- X-ray refraction tomography (2)
- X-ray scattering (2)
- 3D microstructure (1)
- 3D topography (1)
- Advanced Composite (1)
- Advanced ceramics (1)
- Al2O3 ceramics (1)
- Algorithm (1)
- Analyser based imaging (1)
- Analyser-based imaging (1)
- Analyzer based imaging (1)
- Average pore size (1)
- Backlight (1)
- Beta-eucryptite (1)
- Bragg Magnification (1)
- Bragg-Magnification (1)
- Brennstoffzellen (1)
- CFRP (1)
- CT (1)
- Cavitation (1)
- Coherent imaging (1)
- Complex microstructure (1)
- Composite damaging (1)
- Compounds (1)
- Compression device (1)
- Computed topography (1)
- Computerised tomography (1)
- Computertomographie (1)
- Crack Density (1)
- Crack density (1)
- Crystal Texture (1)
- DIVA Algorithm (1)
- DIVA algorithm (1)
- Darkfield imaging (1)
- Detector backlighting (1)
- Detector calibration (1)
- Diesel Fuel (1)
- Double-Crystal-Monochromator with sagittal bender (1)
- Double-Multilayer-Monochromator with meridional bender (1)
- Dual Energy (1)
- Electronic Power Device IC (1)
- FAXOT (1)
- Fatigue (1)
- Fibre Debonding (1)
- Fibre orientation (1)
- Fluorescence screen (1)
- Geometrical tortuosity (1)
- High pressure mercury intrusion (1)
- Holotomography (1)
- Image morphology (1)
- In-Situ Radiologie (1)
- Inner surface (1)
- Inner surface density (1)
- Interface (1)
- Interfaces (1)
- Internal Surfaces (1)
- Internal surface density (1)
- Iterative CT reconstruction (1)
- Kurzzeit-Radiometrie (1)
- Limited View (1)
- Limited tomographic data (1)
- Limited view (1)
- Manifold stack (1)
- Mercury intrusion porosimetry (1)
- Metal Matrix Composites (1)
- Metal matrix composite (MMC) (1)
- Metrology (1)
- Micro cracks (1)
- Micro-CT (1)
- Micro-computed tomography (1)
- Microcracked ceramics (1)
- Microstructure (1)
- Microstructures (1)
- Microtomography (1)
- Molecular probe (1)
- Monochromatische Radiometrie (1)
- Montmorillonites (1)
- Morphological image analysis (1)
- Multiple View Inspection (1)
- Nanocomposites (1)
- Nanocracks (1)
- Nanostructures (1)
- Neutron computed tomography (1)
- Neutronen-Radiographie (1)
- Non-destructive evaluation (1)
- Non-metallics (1)
- Nondestructive characterization (1)
- Nondestructive materials characterisation (1)
- Nondestructive testing (1)
- Opacity (1)
- PE-HD Sorption (1)
- Phase boundary (1)
- Phase contrast radiography (1)
- Phase grating (1)
- Phase-contrast X-ray imaging (1)
- Polymer electrolyte membrane fuel cell (PEMFC) (1)
- Polymers (1)
- Polypropylene-graft-maleic anhydride (1)
- Pore Orientation (1)
- Pore Size (1)
- Pore size analysis (1)
- Porosity fluctuation (1)
- Porous Ceramics (1)
- Quantitative image analysis (1)
- Quenching (1)
- Radiology (1)
- Reconstruction (1)
- Reconstruction algorithms (1)
- Reconstruction algrorithm (1)
- Reflectometry (1)
- Refraction enhanced imaging (REI) (1)
- Rekristallisation (1)
- Renewable energy (1)
- Röntgen-Szintillationsdetektor hoher Zählraten (1)
- SAXS (1)
- SCS6 (1)
- SRCT (1)
- Scanning transmission electron microscopy (STEM) (1)
- Scintillator (1)
- Shearing gratings (1)
- Small angle scattering (1)
- Spatial reslution (1)
- Spatial statistics (1)
- Specific surface area (1)
- Spectral computed tomography (1)
- Statistical analysis (1)
- Strain hardening (1)
- Structural (1)
- Structure property relations (1)
- Surface density (1)
- Synchrotron Laue Contrast Radiography SLCR (1)
- Synchrotron X-ray tomography (1)
- Synchrotron instrumentation (1)
- Synchrotron radiography (1)
- Synchrotron, BAMline (1)
- Synchrotron-CT (1)
- Talbot- Lau interferometry (1)
- Talbot-Lau (1)
- Talbot-Lau interferometer (1)
- Talbot-Lau neutron tomography (1)
- Tensile load (1)
- Terahertz Imaging (1)
- Terahertz time domain spectroscopy (1)
- Terahertz-Radiography (1)
- Texture (1)
- Thermal stability (1)
- Thermoplaste (1)
- Threat Detection (1)
- Three-dimensional data quantification (1)
- Ti6242 (1)
- Titanium Metal Matrix Composites (Ti-MMC) (1)
- Tomographic reconstruction (1)
- Tortuosity (1)
- USAXS (1)
- Visibility (1)
- Water transport path (1)
- Wavelet transform (1)
- Wavelet transformation (1)
- Wide angle X-ray scattering (1)
- X-Ray Computed Tomography (1)
- X-ray absorption and refraction CT (1)
- X-ray computed tomography (1)
- X-ray detector (1)
- X-ray detector scattering (1)
- X-ray diffraction (1)
- X-ray diffraction microscopy (1)
- X-ray fluorescence analysis (1)
- X-ray imaging (1)
- X-ray microscopy (1)
- X-ray phase contrast (1)
- X-ray refractometry (1)
- X-ray scattering topography (1)
- XROT (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (8)
Aiming at ceramic materials of low thermal radiation emittance titania yttrium oxide ceramics have been prepared by sintering in air at 1,100 and 1,400 °C, respectively, and characterised. Due to its high infrared refractive index, average pore sizes up to 1 µm for optimal Mie scattering cross sections and over 35% porosity the material is a promising candidate for elevated temperature insulations. The essentially in large pore growth is achieved by graphitic nano and micro particle additives.
The microstructure parameters of porosity, specific surface area, median and average pore sizes are determined by mercury intrusion porosimetry. Beyond this classical technique supplementary measurements by X-ray Absorption and X-ray refractometry reveal considerably larger average pore sizes due to closed pores not accessible for mercury. An additional advantage of the X-ray techniques is their non-destructive application, which allows other treatments afterwards. The combined application of both methods provides additional information and reliability in case of complex ceramic microstructures and may serve for improved developments of porous ceramics with optimised thermal scattering for energy savings in high temperature applications.
We present an experimental approach to study the three-dimensional microstructure of gas diffusion layer (GDL) materials under realistic compression conditions. A dedicated compression device was designed that allows for synchrotron-tomographic investigation of circular samples under well-defined compression conditions. The tomographic data provide the experimental basis for stochastic modeling of nonwoven GDL materials. A plain compression tool is used to study the fiber courses in the material at different compression stages. Transport relevant geometrical parameters, such as porosity, pore size, and tortuosity distributions, are exemplarily evaluated for a GDL sample in the uncompressed state and for a compression of 30 vol.%. To mimic the geometry of the flow-field, we employed a compression punch with an integrated channel-rib-profile. It turned out that the GDL material is homogeneously compressed under the ribs, however, much less compressed underneath the channel. GDL fibers extend far into the channel volume where they might interfere with the convective gas transport and the removal of liquid water from the cell.
This paper gives a brief overview on3D imaging of magnetic domains with shearing grating neutron tomography. We investigated the three-dimensional distribution of magnetic domain walls in the bulk of a wedge-shaped FeSi single crystal. The width of the magnetic domains wasanalyzed at different locations within the crystal. Magnetic domains close to the tip of the wedge are much smaller than in the bulk. Furthermore, the three-dimensional shape of individual domains wasinvestigated. We discuss prospects and limitations of the applied measurement technique.
Grating interferometric set-ups have been established in the last decade. They are promising candidates to obtain enhanced image contrast from weakly absorbing micro and nano structures. They are based on X-ray refraction and near-field diffraction using the Talbot effect.
At the expense of taking multiple images, Talbot-Lau grating interferometry allows separating the absorption, refraction, and scattering contributions by analysing the disturbances of a phase grating interference pattern. Contrary to other refraction enhanced methods, this technique can be applied using conventional X-ray tubes (divergent, polychromatic source). This makes it attractive to solve typical non-destructive testing problems.
We investigated the efficiency of phase gratings, i.e. the visibility (the amplitude of oscillations) upon variation of propagation distance and phase grating rotation around an axis parallel to the grid lines. This grating rotation changes the grating shape (i.e. the distributions of phase shifts). This can yield higher visibilities than derived from rectangular shapes.
Our study includes experimental results obtained from synchrotron radiation, as well as simulations for monochromatic radiation. The advantages of Talbot-Lau interferometry are demonstrated at the example of glass capillaries.
High-density polyethylene becomes optically transparent during tensile drawing when previously saturated with diesel fuel. This unusual phenomenon is investigated as it might allow conclusions with respect to the material behavior. Microscopy, differential scanning calorimetry, density measurements are applied together with two scanning X-ray scattering techniques: wide angle X-ray scattering (WAXS) and X-ray refraction, able to extract the spatially resolved crystal orientation and internal surface, respectively. The sorbed diesel softens the material and significantly alters the yielding characteristics. Although the crystallinity among stretched regions is similar, a virgin reference sample exhibits strain whitening during stretching, while the diesel-saturated sample becomes transparent. The WAXS results reveal a pronounced fiber texture in the tensile direction in the stretched region and an isotropic orientation in the unstretched region. This texture implies the formation of fibrils in the stretched region, while spherulites remain intact in the unstretched parts of the specimens. X-ray refraction reveals a preferred orientation of internal surfaces along the tensile direction in the stretched region of virgin samples, while the sample stretched in the diesel-saturated state shows no internal surfaces at all. Besides from stretching saturated samples, optical transparency is also obtained from sorbing samples in diesel after stretching.
A strategy to mitigate typical reconstruction artefacts in missing wedge computed tomography is presented. These artefacts appear as elongations of reconstructed details along the mean direction (i.e. the symmetry centre of the projections). Although absent in standard computed tomography applications, they are most prominent in advanced electron tomography and also in special topics of X-ray and Neutron tomography under restricted geometric boundary conditions. We investigate the Performance of the DIRECTT (Direct Iterative Reconstruction of Computed Tomography Trajectories) algorithm to reduce the directional artefacts in standard procedures. In order to be sensitive to the anisotropic nature of missing wedge artefacts, we investigate isotropic substructures of metal foam as well as circular disc models. Comparison is drawn to filtered backprojection and algebraic techniques. Reference is made to reconstructions of complete data sets. For the purpose of assessing the reconstruction Quality, Fourier transforms are employed to visualize the missing wedge directly. Deficient reconstructions of disc models are evaluated by a length-weighted boundary orientations. The DIRECTT results are assessd at different signal-to-noise ratios by means of local and integral evaluation Parameters.
The potentials of incoherent X-ray scattering (Compton) computed tomography (CT) are investigated. The imaging of materials of very different atomic number or density at once is generally a perpetual challenge for X-ray tomography or radiography. In a basic laboratory set-up for simultaneous perpendicular Compton scattering and direct beam attenuation tomography are conducted by single channel photon counting line scans. This results in asymmetric distortions of the projection profiles of the scattering CT data set. In a first approach, corrections of Compton scattering data by taking advantage of rotational symmetry yield tomograms without major geometric artefacts. A cylindrical sample composed of PE, PA, PVC, glass and wood demonstrates similar Compton contrast for all the substances, while the conventional absorption tomogram only reveals the two high order materials. Comparison to neutron tomography
reveals astonishing similarities except for the glass component (without hydrogen). Therefore, Compton CT offers the potential to replace neutron tomography, which requires much more efforts.
The performance of grating interferometers coming up now for Imaging interfaces within materials depends on the efficiency (visibility) of their main component, namely the phase grating. Therefore, experiments with monochromatic synchrotron radiation and corresponding simulations are carried out. The visibility of a Phase grating is optimized by different photon energies, varying detector to grating distances and continuous rotation of the phase grating about the grid lines. Such kind of rotation changes the projected grating shapes, and thereby the distribution profiles of phase shifts. This yields higher visibilities than derived from ideal rectangular shapes. By continuous grating rotation and variation of the propagation distance, we achieve 2D visibility maps. Such maps provide the visibility for a certain combination of grating orientation and detector position. Optimum visibilities occur at considerably smaller distances than in the standard setup.
In order to investigate their microcracking behaviour, the microstructures of several β-eucryptite ceramics, obtained from glass precursor and cerammed to yield different grain sizes and microcrack densities, were characterized by laboratory and synchrotron x-ray refraction and tomography. Results were compared with those obtained from scanning electron microscopy (SEM). In SEM images, the characterized materials appeared fully dense but computed tomography showed the presence of pore clusters. Uniaxial tensile testing was performed on specimens while strain maps were recorded and analyzed by Digital Image Correlation (DIC). X-ray refraction techniques were applied on specimens before and after tensile testing to measure the amount of the internal specific surface (i.e., area per unit volume). X-ray refraction revealed that (a) the small grain size (SGS) material contained a large specific surface, originating from the grain boundaries and the interfaces of TiO2 precipitates; (b) the medium (MGS) and large grain size (LGS) materials possessed higher amounts of specific surface compared to SGS material due to microcracks, which decreased after tensile loading; (c) the precursor glass had negligible internal surface. The unexpected decrease in the internal surface of MGS and LGS after tensile testing is explained by the presence of compressive regions in the DIC strain maps and further by theoretical arguments. It is suggested that while some microcracks merge via propagation, more close mechanically, thereby explaining the observed X-ray refraction results. The mechanisms proposed would allow the development of a strain hardening route in ceramics.