The active approach for non-destructive-testing in Civil Engineering (NDT-CE) with infraredthermography (IR), developed at the Federal Institute for Materials Research and Testing (BAM), is described in part one of this contribution. The active IR-approach is based on the principles of impulse- (IT) and pulse-phase-thermography (PPT). The concept is a direct result of a research project at the BAM in cooperation with the Technical University of Berlin (TUB) and was funded by the Deutsche Forschungsgemeinschaft (DFG). In the second part results of the new thermography-scanning system (thermo-scanner) of BAM on debonding of multi-layered structures, especially carbon fibre reinforced plates (CFRP) on concrete are presented. Both, the thermo-scanner developed at BAM, and the investigations carried out, are part of the
EU-Project Sustainable Bridges. In the third part of the paper the characteristic frequency of the optimum phase-contrast as a means for the characterization of defects depth in CE by means of PPT is introduced. A new quantitative approach is tested and discussed on concrete structures with defects of polystyrene and gas concrete.
Berlin Main Station is the largest multi-level station in Europe. Its daily passenger number amounts to over 300.000. Structures built for such a large number of people require a high-level safety standard. The station was built on the inner city site of the historic Lehrter Bahnhof. The conditions for building and start of operation were challenging by several reasons. The typical sandy ground with a high level of groundwater makes the permanent static stability of such a complex structure difficult. Several completed, ongoing, and planned construction activities in the immediate vicinity of the station influence the ground settlement of the whole area. On basis of the structural design an impact prediction was calculated, which expected certain vertical displacements particularly between the single columns of the outer concrete bridges of the building. These columns support the glass roof construction, which only allows a defined limit of displacement. In order to avoid damage, a concept for monitoring and adjusting potentially occurring displacements was developed for installation at the outer bridges of the station.
Condition assessment of old railway bridges, a scientific cooperation between Berlin and Wroclaw
(2009)
Two years ago, the East Prussian and the Low-Silesian Railway lines celebrated their 160th anniversaries. The history of both first railway connections in the Eastern railway network development in the whole region in the 19th century is presented together with information about the railway between Berlin and Wroclaw. Special attention is paid to the railway bridges built in this period. The first large iron bridges and typical masonry arch structures are presented. Special attention is paid to masonry arches. The condition appraisal of existing masonry arches requires new developed technical methodologies, effective tools and procedures for the description of the bridges current state and function. Their current technical condition as well as service-ability is described.
The construction process of the New Berlin Main Station, the former Lehrter Bahnhof, has been monitored from the beginning. In this station, the main European east-western railway connection crosses the northsouth railway lines. Four east-western bridges, built in the first construction phase, carry the platforms for international lines and suburban train tracks. The outer two bridges carry the supports of the relatively flat glass roof, too. Since the glass roof is very sensitive to vertical displacements, the authorities required a complex monitoring system. This case study describes long-term measurements with classical and enhanced innovative sensors to monitor vertical displacements of neighboring glass roof supports. Additionally, traditional strain gauges were embedded parallel to long-gauge length fiber-optic strain sensors in the near-surface concrete of the partial prestressed bridges to reliably survey possible changes.
The measurements on site go along with long-term laboratory tests on prestressed concrete beams. Researchers study load effects and long-term environmental influences on two large-scale model beams, inside and outside the laboratory.
The monitoring system has been working stable as an early warning system for any changes of the structural conditions since 2002. All data are available on line for both the project team and the owner.