Proposals for Performance Demonstration and Modular Reliability Assessment for Humanitarian Demining
(2003)
For safe and reliable demining it is necessary to determine the actual true performance of mine searching equipment in detecting mines. The subject to detect a hidden subject by penetrating physical interaction with the target is similar to that of non-destructive testing where it is looked for hidden cracks etc. in material via waves and rays. The non destructive testing profession is now about 100 years old and developed some procedures to check reliability of testing. Those principles like the performance demonstration where the successful detections are statistically evaluated against false calls rates and their implementation in an industrial standard (ASME section XI appendix VIII) are analysed. A first adoption to demining was accomplished in the prescription for blind trials in the CEN workshop agreement CEN BT 126
CWA07 for test and evaluation of metal detectors. A number of blind trials were accomplished within an ITEP project to learn about the necessary statistical layout of those trials to achieve true, reproducible and repeatable results to give guidance to selection and improvement of metal detectors. The special focus in these investigations was on the influence of the human factor due to the degree of experience of the operators and the infulence of uncooperative soil. The correlation of the results of the physical parameter measurement and the statistical results is analysed in a first attempt.
This paper gives an introduction to the field of human factors with the focus on their influence on the reliability of NDT in the nuclear energy production (in-service inspections) and final storage of highly radioactive nuclear waste. A set of methodological tools has been developed in the scope of three projects, namely: 1) a theoretical model describing potential human factors influencing manual ultrasonic inspection performance during inservice inspections in nuclear power plants; 2) a method for identifying potential human errors during acquisition and evaluation of data gathered with mechanized ultrasonic, radiographic and eddy-current systems, as well as visual testing with a remote camera (Failure Modes and Effects Analysis, FMEA); and 3) use of eye tracking methodology to optimize existing procedures and practices. The experimental results have shown that time pressure, mental workload and experience influence the quality of the inspection performance. Noticeable were influences from the organization of the working schedule, communication, procedures, supervision and demonstration task. Implementing human redundancy in critical tasks, such as defect identification, as well as using an automated aid (software) to help operators in decision making about the existence and size of defects, could lead to other kinds of problems, namely social loafing (excerpting less effort when working on tasks collectively as compared to working alone) and automation bias (uncritical reliance on the proper function of an automated system without recognizing its limitations and the possibilities of automation failure) that might affect the reliability of NDT in an undesired manner.
Ferroelectrets are promising materials for air-coupled ultrasonic transducers. A transducer made of polarized cellular polypropylene, including its electronic interface, was developed and compared with conventional air-coupled probes. Test pieces of fiber-reinforced polymer containing impact flaws and flat-bottom holes were inspected in transmission. The ferroelectret transducers achieved a considerably higher signal-to-noise ratio. The impacts were clearly visible with all transducers, but less noisy with ferroelectret transducers. The flat-bottom holes were better detectable than with a conventional probe with about the same focus size.
Trial Design for Testing and Evaluation of Metal Detectors Used in Humanitarian Landmine Clearance
(2006)
NDT is a multidisciplinary research area fusing the disciplines of natural Science and engineering. Particularly in the early development stages of a new testing method, feasibility investigations focus on the fundamental physical interaction between the sensing mechanism and specimen. Research activities during subsequent phases of modular prototype development, technical System Integration and Validation primarily attempt to solve the practical engineering and real-life aspects of a testing method. We show several examples of new methods in different stages of development and highlight the potential for further industrial use. The first section deals with Steel surfaces of lightweight components which are
inspected with pm-sized magneto resistive sensor arrays. This quantitative magnetic stray field approach combines high spatial resolution and very high sensitivity, enabling the user to detect even very small micro-defects. Tuming to CFRP components we also show new developments in airbome ultrasonic testing. Here we use ferroelectret foils to reduce the acoustical mismatch between transducer and air, which enhances the signal-to-noise ratio. A further example illuminates the use of metallic nano layers as a broadband thermo acoustical emitter. Their use provides both high sound pressures and very broadband Signal characteristics. When it comes to CFRP components and other anisotropic and highly Scattering materials, ultrasonic matrix arrays in conjunction with many angles of incidences per transducer position can help to enhance the statistics of a testing problem. In the field of conventional water-coupled UT testing we also show the use of matrix array transducers
providing a tomographic-like 3D-image of impact damage in CFRP samples.
The extremely low acoustic impedance of polypropylene ferroelectret combined with its piezoelectric properties makes this material suitable for construction of aircoupled ultrasonic transducers for non-destructive testing. For the fabrication of transducers with a stable quality, the reproducibility of their key parameters is of interest.
The reproducibility was evaluated by means of (i) impedance spectroscopy and (ii) pulse-echo measurements. (i) Impedance spectroscopy was applied to identify the resonance frequency, the coupling factor and the acoustic impedance of several nominally identical transducers. (ii) Pulse-echo measurements yielded the signal form of these transducers.
The variation of the signal amplitude measured with pulseecho technique was about 10 dB. A part of this variation Comes from the deposition of transducer electrodes and another part from local variations of ferroelectret properties. The variation of the signal amplitude was caused by the observed variation of the coupling factor, which was also about 10 dB. The variation of the acoustic impedance was only about 1 dB, thus having no effect on the variation of the signal amplitude.
These results indicate that the variability can be reduced by improving the control of electrode deposition and by optimizing the production technology affecting the reproducibility of material properties.
Air-coupled ferroelectret ultrasonic transducers applied to testing of fiber-reinforced polymers
(2013)
Atmospheric pressure plasmas interact in various physical ways with their surroundings. They release heat and generate charge carriers, which leads to two effects. The first effect is the generation of acoustic waves due to heat release, known as the thermoacoustic effect, and the second effect is the perturbation of the resting fluid provoked by the release of charge carriers, called “ionic wind”. The direct connection between the charge carrier production of the discharge arrangement and the surroundings also allows the detection of acoustic waves by tracking the electrical current of the arrangement.
This contribution introduces a multi-fluid model approach to describe the acoustic interaction of atmospheric plasmas. In addition, we present experimental results on commercially available and in-house fabricated discharge arrangements for either emitting or receiving acoustic waves.
Novel air-coupled ultrasonic transducer combining the thermoacoustic with the piezoelectric effect
(2016)
In recent years, there has been an increasing industrial demand for one-sided inspection of various structures by means of air-coupled ultrasonic technique. Lightweight structures based on carbon-fibre-reinforced polymers may have very complex shapes, making air-coupled transmission difficult or even impossible. The inspection of concrete structures is another example where one-sided inspection is required.
To address these challenges a new type of transducer for air-coupled pulse-echo inspection was developed, which unites two principles: thermoacoustic emission and piezoelectric reception. The thermoacoustic emitter is a titanium electrode with a thickness of several tens of nanometer. This electrode was deposited onto charged cellular polypropylene, which serves as a piezoelectric receiver. The thermoacoustic transmission is based on a transformation of the thermal energy of an electrically heated electrode into the acoustic energy of an ultrasonic wave. Thermoacoustic emitters provide resonance-free behaviour and thus extremely broadband pulses. Charged cellular polypropylene is piezoelectric due to the polarization of its cells and it is well matched to air, with a Young modulus in the order of magnitude of MPa. In this contribution we present some pulse-echo measurements with the first prototypes of the combined thermoacoustic-piezoelectric transducer.