The new standard ‘ISO 17636-2:2013: Non-destructive testing of welds — Radiographic testing — Part 2: X- and gamma-ray techniques with digital detectors’, defines the practice for radiographic inspection of welded pipes for manufacturing and in-service inspection. It is applied in Europe for inspections of pipe welds in nuclear power plants as well as in chemical plants and allows a faster inspection with digital detector arrays (DDA) than with film. Nevertheless, it does not allow the evaluation of the depth and shape of volumetric and planar indications. In 2001 a planar tomography scanner, TomoCAR, was introduced for mechanized radiographic testing (RT) inspection and non-destructive measurement of cross sections. The project TomoWELD is based on a new concept of the scan geometry, an enhanced GPU based reconstruction, and the application of a new generation of photon counting DDAs based on CdTe crystal CMOS hybrids. The new detector permits the selection of energy thresholds to obtain an optimum energy range and reduction of the influence of scattered radiation. The concept and first measurements are presented. Flaw depth and shape of volumetric and planar irregularities can be determined.
The inspection of the sealing weld is an important phase for the evaluation of the acceptability of final disposal canister, but the weld is only a part of the 3D shielding of copper shell. The main tasks for reliable NDT evaluation requires an extensive evaluation of the parameters which contains typical inspection related items like repeatability, S/N ratio, POD, setting up the equipment for inspection, and all practices for inspections. The other parameters are material parameters, their variation must be taken into account in the evaluation of NDT reliability. Further parameters include human factors, i. e. human inspectors and their interaction with technical systems; their effects were studied on an example of the evaluation of eddy current data. Final parameters are related to evaluation of detected defects, which means sizing and base for acceptance and this can be done in different ways. Some examples are given and results are compared with different methods for instance between radiographic testing and ultrasonic testing by raw data analysis and PA-SAFT results. Also, preliminary curves for the evaluation of metallographic results of 55 defects will be shown by EB weld measurements. Some practical items concerning copper inspections will be also discussed related to acceptability.
In situ crack detection in the mushy zone and the solid weld of a gas tungsten arc (GTA) weld using X-ray imaging during welding is a new research area for NDT inspection. Usually, NDT flaw detection is done after the complete solidification of the weld seam. In this paper, we present the use of real-time radiography with a minifocus X-ray source (YXLON X-ray tube Y.TU 225-D04) and a 75μm pixel size digital detector array (Dexela 1512) for the acquisition of 2D radiographic images by a sequence of exposures with time intervals of 80 ms for hot crack detection during single pass bead-on-plate GTA welding of 3 mm thick plates of aluminium alloy AlMgSi (6060). An analysis of the crack distribution in the weld sample is conducted from the acquired 2D radiographs and its corresponding 3D volumetric reconstruction achieved by linear coplanar digital laminography.
This in situ approach opens new possibilities in the field of hot crack research by having the direct information of both the crack initiation and growth and its correlation to the welding parameters.
This work presents the use of limited experimental measurements to develop a set of calibrated Simulation parameters that can then be used for reliable simulation of subsea pipeline inspections. The modelling software aRTist is used as the simulation tool, and the calibration is through comparison with experimental images of a well characterised sample in a water tank. Image Quality parameters such as signal-to-noise ratio, contrast and basic spatial resolution are compared with the aim of matching simulated values to experimental results. Currently the model is partially calibrated, with signal-to-noise ratio successfully matched while differences are still found in contrast-to-noise ratio comparisons. This means that measurements depending on absolute intensity are not accurate enough in the simulation at this stage. However, the simulation is found to be accurate for wall thickness measurements in tangential images, which are not based on absolute intensity, with simulated and experimental cases producing similar results.
Determining scatter ratios at high energies (> ~ 1MeV) presents challenges not immediately obvious from measurements at conventional X-ray energies. This includes reduced attenuation even in heavy elements as well as a stronger forward bias of scattering. In order to check the reliability of different measurement setups with regard to material thicknesses, distances, and collimation, attenuation and scattering were separately simulated using a Monte Carlo model. The simulation results help in understanding the sources of radiation scattered into the detection area, thereby aiding in eliminating undesired contributions.
Innovative X-ray backscatter technique for security applications: Detection of dangerous materials
(2014)
Radiological inspections, in general, are NDT&E methods to detect the bulk of explosives without invasion into the object of analysis. In contrast to personal luggage, cargo or structural components constitute a complexity that may significantly hamper the detection of a threat by conventional transmission radiography. A novel approach of interrogating a large object to a certain depth only with a single sided access will be presented. It consists of an X-ray backscatter camera with a special twisted slit collimator for imaging backscattered objects. The new X-ray backscatter camera is not only imaging the objects due to their densities but also by taking into account the influences of surrounding objects. Additionally, it does not only image illuminated features but also depicts shadows from absorbing materials. This is a unique characteristic of the developed X-ray backscatter camera. Experimental mock-ups are conducted imitating container with threats among a complex packing as they may be encountered in reality. At the end, the significant advantages of the presented X-ray backscatter camera in the context of aviation and port security will be discussed.
An algorithm has been developed to remove reliably dotted interferences impairing the perceptibility of objects within a radiographic image. This particularly is a major challenge encountered with neutron radiographs collected at the NECTAR facility, Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRM II): the resulting images are dominated by features resembling a snow flurry. These artefacts are caused by scattered neutrons, gamma radiation, cosmic radiation, etc. all hitting the detector CCD directly in spite of a sophisticated shielding. This makes such images rather useless for further direct evaluations.
One approach to resolve this problem of these random effects would be to collect a vast number of single images, to combine them appropriately and to process them with common image filtering procedures. However, it has been shown that, e.g. median filtering, depending on the kernel size in the plane and/or the number of single shots to be combined, is either insufficient or tends to blur sharp lined structures. This inevitably makes a visually controlled processing image by image unavoidable. Particularly in tomographic studies, it would be by far too tedious to treat each single projection by this way. Alternatively, it would be not only more comfortable but also in many cases the only reasonable approach to filter a stack of images in a batch procedure to get rid of the disturbing interferences.
The algorithm presented here meets all these requirements. It reliably frees the images from the snowy pattern described above without the loss of fine structures and without a general blurring of the image. It consists of an iterative, within a batch procedure parameter free filtering algorithm aiming to eliminate the often complex interfering artefacts while leaving the original information untouched as far as possible.
Der Ersatz von Röntgenfilmen durch digitale Detektoren in der zerstörungsfreien Prüfung wurde in den letzten 10 Jahren kontrovers diskutiert. Nach der Erfolgsgeschichte der digitalen Photographie und der fast vollständigen Ablösung der Filmtechnik in der optischen Bilderfassung wurde erwartet, dass sich der Übergang von der Filmradiographie zur digitalen Radiographie schnell vollziehen sollte. Dieser Trend ist derzeit so noch nicht zu beobachten. Zur mobilen Prüfung wird in Europa immer noch vorrangig die Filmradiographie und nur teilweise die Speicherfolientechnik eingesetzt. Im Bereich der stationären Prüftechnik haben sich die Matrixdetektoren (DDA) weitgehend durchgesetzt, wobei es auch hier noch alternative Detektoren wie Bildverstärker und Fluoroskope gibt. Mit Einführung der DIN EN ISO 17636-2 wird seit 2013 erstmalig geregelt, wie man einen digitalen Detektor für die technische Radiographie auswählen soll, um im Vergleich zur Filmradiographie eine äquivalente Bildqualität zu erhalten. Essentielle Parameter bestimmen, ob die geforderte Bildgüte erreicht werden kann. Es wird ein Überblick gegeben, welche Parameter zum praktischen Einsatz wichtig sind und wie sie ermittelt werden. Erste Erfahrungen im praktischen Einsatz werden diskutiert.