Organisationseinheit der BAM
Deuterated polystyrene (D-PS) improves microplastic detection with TED-GC / MS, among other things through higher reproducibility. It is inexpensive (0.1 ct / analysis) and can be dosed quickly and reproducibly thanks to its good solubility (e.g. in toluene). However, certain matrices lead to an exchange of the deuterium with hydrogen. The poster shows the measuring principle, in which matrices H/D-exchange takes place, the results of kinetic studies and ways of preventing or circumventing the H/D-exchange.
Deuteriertes Polystyrol (D-PS) verbessert die Mikroplastikdetektion mit der TED-GC/MS, u.a. durch höhere Reproduzierbarkeit. Es ist kostengünstig (0,1 ct/Analyse) und durch die gute Löslichkeit (z.B. in Toluol) schnell und reproduzierbar zu dosieren. Bestimmte Matrices führen jedoch zu einem Austausch des Deuteriums durchWasserstoff. Das Poster zeigt das Messprinzip, bei welchen Matrices H/D-Austausch erfolgt, Ergebnisse von Kinetikuntersuchungen sowie Möglichkeiten, den Austausch zu verhindern oder zu umgehen.
The presence of plastic debris and especially small plastic particles in marine ecosystems has been recognized in the 1970`s. Since then various other environmental systems all over the world, like rivers, lakes and biota have been found to be polluted by plastics. Lately, agriculturally used land, waste-water treatment and biogas facilities come into focus as possibly relevant distribution vectors. To monitor the situation and investigate distribution pathways, the need for fast and reliable analytical procedures is high.
Up to now, there is no standard procedure for sampling, concentrating and analyzing plastic particles in environmental samples. Our group recently reported the development of a new analyzing method for microscale plastic particles, thermal extraction desorption gas chromatography mass spectrometry (TED-GC-MS). This method consists of thermal extraction of the sample via thermogravimetric analysis, collection of the evolved gaseous decomposition products on a solid-phase adsorber and analysis of the loaded adsorber using Thermal-Desorption-GC-MS. This technique utilizes the characteristic decomposition products of polymers for identification and even quantification of plastics in environmental samples.
In the present work we investigated samples of fermentation residues taken from a biogas plant. The results of sample preparation, concentration and analysis are presented as well as a comparison with alternative methods.
The first analysis of environmental samples shows, that the use of TED-GC-MS is suitable to analyse microplastic in environmental samples. Compared to the micro-spectroscopic methods this method is faster and gives good hints to the occurrence of high loadings of MP in environmental samples. In consequence, the method allows the monitoring of the situation and the investigation of MP distribution pathways in environment, to assess the relevance of various inputs.
Die ThermoExtraktionDesorption-Gaschromatografie-Massenspektrometrie (TED-GC-MS) ist die wichtigste Methode der BAM zur Analyse von Mikroplastikpartikeln in Umweltproben. Mit wachsendem Erfahrungsschatz traten Komplikationen auf, bei deren Bewältigung das Analysensystem verbessert werden konnte. Das Poster präsentiert u. a. die Verbesserung der Nachweisgrenzen sowie die Eliminierung von Kontaminationsquellen aus gängigen Probennahmeverfahren.
Die weltweite Produktion von synthetischen Kunststoffen steigt stetig und ein Teil gelangt in die Umwelt. Die Kunststofffragmente werden durch Umwelteinflüsse zerkleinert und bilden schließlich Mikroplastik, dessen Gefährdungspotential intensiv diskutiert wird. Zur Beobachtung und Bewertung der Situation ist eine leistungsstarke und schnelle Analytik erforderlich, jedoch existieren noch keine harmonisierten Verfahren. Die ThermoExtraktionDesorption-GasChromatograpie-MassenSpektrometrie (TED-GC-MS) nutzt polymer-spezifische Zersetzungsprodukte und bietet durch ihre Schnelligkeit und Robustheit Vorteile gegenüber anderen Verfahren.
Die Thermo Extraktion Desorption Gas Chromatograpie Massen Spektrometrie (TED-GC/MS) ist ein schnelles thermoanalytisches Verfahren zur Bestimmung von Gehalten an Mikroplastik (MP). Die Kombination aus teils schwerflüchtigen Analyten und Kältebrücken führt zu Memory-Effekten, denen u.a. durch häufige Blindwertmessungen begegnet werden muss. Reduzierte Probedurchsätze sind die Folge. Um Messergebnisse abzusichern und den Gerätestatus bei gleichzeitig hoher Messleistung überwachen zu können, wurde die sequentielle Standardmethode überarbeitet.