Filtern
Dokumenttyp
- Zeitschriftenartikel (12) (entfernen)
Sprache
- Englisch (12) (entfernen)
Schlagworte
- Monitoring (2)
- Polymer optical fiber (2)
- Additive Manufacturing (1)
- Ageing (1)
- Aging (1)
- Air-based (1)
- Application (1)
- Brillouin scattering (1)
- Brillouin-Streuung (1)
- Characterisation (1)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (2)
- 4 Material und Umwelt (1)
- 4.2 Material-Mikrobiom Wechselwirkungen (1)
- 5 Werkstofftechnik (1)
- 5.1 Mikrostruktur Design und Degradation (1)
- 5.2 Metallische Hochtemperaturwerkstoffe (1)
- 5.4 Multimateriale Fertigungsprozesse (1)
- 8.0 Abteilungsleitung und andere (1)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (1)
- 8.3 Thermografische Verfahren (1)
In this work an air-based sensor network for the localization of persons at extensive areas is presented. The developed network consists of a localization device which the person is wearing (BodyGuard-System), a mobile relay station in the air, and a base station. All three parts communicate with the same radio chip. The BodyGuard-System is an inertial navigation system which was developed for localization in difficult environments with high accuracy and low measurement uncertainty. To increase the range of the system, a multi-hop network was built up. The measured data of the BodyGuard-System and the mobile relay station is visualized on a PC in the base station. This multi-hop network is necessary for example for fire department missions.
High quality tubular products are essential to the oil and gas industry. Quality control during their production focuses on the non-destructive detection of surface defects. The structured light technique is a candidate for the challenge to detect, monitor and evaluate such defects in real-time.
In the present study the automatic processing of structured light measurements is performed and validated. The algorithm for the automatic Analysis of inspection data has an advantage over current data evaluation methods based on individual assessments of operators.
The thermo-oxidative stability of commercially available polymer optical fibers (POFs) and their components (cores and claddings) was investigated. All the bare POFs (core and cladding only) studied here were based on poly(methyl methacrylate) (PMMA) core. The fibers were exposed to 100 °C/low humidity for about 4200 h. Chemiluminescence (CL) technique was applied to investigate the thermo-oxidative stability and for measuring the transmission loss during exposure a prototype device called multiplexer was used. POFs exhibited variation in thermo-oxidative stability although they possessed identical core material PMMA. This was due to difference in the chemical compositions of claddings. Claddings were more susceptible to the thermo-oxidative degradation compared to cores. The thermo-oxidative degradation of both the cladding and the core was found in POFs as a result of climatic exposure. POFs showed an early drop-off followed by a slow decline of transmission. The early drop-off of transmission was attributed to physical changes like thermal expansion and the slow decline of transmission to chemical changes like oxidative degradation of POFs. A good linear relationship between optical transmission stability and thermo-oxidative stability of POFs was established from these studies.
The optical transmission stability was investigated for commercially available polymer optical fibers (POFs) which were exposed to a climate of 92°C and 95% relative humidity for about 3300 h. The optical transmission stability of POFs was correlated to their thermooxidative stability. POFs possessed identical core material, poly(methyl methacrylate), but they differed in the materials used for the claddings. The optical transmission was measured online using a prototype device called multiplexer. The chemiluminescence (CL) technique was applied to characterize the thermooxidative stability and degradation of POFs. CL analysis reveals the thermooxidative degradation of bare POFs (core and cladding), predominantly of the claddings, as a result of climatic exposure. Ultraviolet-visible transmittance measurements demonstrated more changes in the claddings as compared to the cores due to degradation. The CL and optical measurements data indicated that the optical transmission stability of POFs was dependent mainly on the thermooxidative stability of the claddings and their chemical compositions.
Embedded conventional fibre Bragg grating (FBG) sensors with acrylate coating have been chosen for monitoring novel textile-reinforced composite materials with a complicated wavy structure as a result of reinforcing textures. Problems of monitoring this type of material occur due to the harsh fabrication technology of the composite and its complicated structure. Embedded fibre sensors are exposed to the influence of transverse and point-wise deformations. To what extent will these effects influence the measurement signal of a sensor? Temperature cycles, tension and vibration tests were carried out to answer this question. Transverse and point-wise deformation and micromechanical indentation tests on non-embedded FBG sensors were carried out to clarify the reliability of recorded signals.
Innovative structural damage detection of bridges by least squares adjustment with constraints
(2016)
Long-term monitoring of bridges requires the early detection of spreading damage because very often the damage is not really visible. For many decades engineers and scientists relayed on dynamic methods especially modal ones. However, after fundamental tests by the U.S. FHWA in 1993, it became evident that more successful methods should be developed, but no innovation really happened. A substantial innovative detection method started four years ago from Lagrange Multiplier Testing which eventually resulted in experimental verification based on measurement of deflection and curvature of the bridge beam and together the methodological combination of both.
Fiber optic sensors have gained increasing importance in recent years and are well established in many areas of industrial applications. In this paper, we introduce a concept of a self-diagnostic fiber optic sensor. The presented sensor is to resolve the problems of embedded fiber optic sensors in complex structures and to enable the validation under operational conditions. For this purpose, different magnetostrictive coated fiber optic sensors were developed and various experiments were performed to verify their mode of Operation and to determine the respective reproducibility. The measuring principle is illustrated by obtained experimental results, which showed a change in wavelength from 1 pm at a magnetic field strength change of 0.25 mT.
In addition, the temperature characteristics of the implemented magnetostrictive sensor were analyzed and an experimental factor of 1.5 compared to a reference fiber optic sensor was determined.
Measurement and data recording systems are important parts of a holistic Structural Health Monitoring (SHM) system.
New sensor technologies such as fiber-optic sensors are often used; however, standards (or at least guidelines) are not yet available or internationally approved. This lack in standardization makes the acceptance of FOS technologies in complex SHM systems substantially difficult. A standard family for different FOS technologies is therefore being developed that should help to design SHM systems in an optimal way. International standardization activities take place in several standardization bodies such as IEC and ASTM, and within SHM societies such as ISHMII.
The paper reports on activities in standardization of fiber-optic sensors, on results already achieved, and on newly started projects. Combined activities of fiber sensor experts and SHM experts from Civil Engineering are presented. These contributions should help owners of structures as well as developers of sensors and monitoring systems to select effective and validated sensing technologies. Using these standards, both parties find recommendations how to proceed in development of SHM systems to evaluate the structural behavior based on e.g. standardized fiber optic sensors, and to derive necessary measures, e.g. the optimal maintenance strategy.
Sensing with optical fibres
(2014)
Starting from the first patent of a fibre optic sensor in 1967, fibre optic sensing has become a success story throughout the world. Today, fibre optic point sensors and continuous distributed fibre optics sensor systems allow the measurement of nearly all physical quantities and contribute to higher safety levels in many industrial sectors. Monitoring of pipelines, power cables, lightweight and civil engineering structures, and of ground movements are heading the hit list of applications. Standardization in this field is of paramount relevance and brings to light some of the challenges now faced by IEC SC (Subcommittee) 86C/WG (Working Group) 2: Fibre optic sensors.
Structural health monitoring by distributed fiber optic sensors embedded into technical textiles
(2012)
Technical textiles with embedded distributed fiber optic sensors have been developed for the purposes of structural health monitoring in geotechnical and civil engineering. The distributed fiber optic sensors are based on Brillouin scattering in silica optical fibers and OTDR in polymer optical fibers. Such 'smart' technical textiles are used for reinforcement of geotechnical and masonry structures. The embedded fiber optic sensors provide online information about the condition of the structure and about the occurrence and location of any damage or degradation.--------------------------------------------------------------------------------------------------------------------------------------------------------
Technische Textilien mit integrierten faseroptischen Sensoren eröffnen neue Möglichkeiten der Zustandsüberwachung (structural health monitoring) in Geotechnik und Ingenieurbau. Die verteilt messenden Sensoren basieren auf der Brillouin-Streuung in Glasfasern und auf der OTDR in polymeroptischen Fasern. Derartige 'intelligente' technische Textilien werden in erster Line zur Verstärkung von geotechnischen Bauwerken und von Gebäuden genutzt. Die integrierten Sensoren liefern eine zeitnahe Information über den bestimmungsgemäßen Zustand des Bauwerks sowie über die Entstehung und den Ort von lokalen Bauwerksschäden.
The stress vs. strain curve of materials is affected the rate of imposed straining. Among the methods for dynamic testing the technique known as 'split Hopkinson pressure bar' (SHPB) has evolved into the most widely used one to exert high-speed straining. The theory behind it comprises simple equations to compute stress and strain. The reliability of the strain analysis can be assessed by digital image correlation (DIC). The present results indicate that the visually observed strain is smaller than predicted by theory.