VDI/VDE-Guideline 5570 - The First Comprehensive Standard on Characterization and Testing of POF
(2002)
In this work an air-based sensor network for the localization of persons at extensive areas is presented. The developed network consists of a localization device which the person is wearing (BodyGuard-System), a mobile relay station in the air, and a base station. All three parts communicate with the same radio chip. The BodyGuard-System is an inertial navigation system which was developed for localization in difficult environments with high accuracy and low measurement uncertainty. To increase the range of the system, a multi-hop network was built up. The measured data of the BodyGuard-System and the mobile relay station is visualized on a PC in the base station. This multi-hop network is necessary for example for fire department missions.
Berlin Main Station is the largest multi-level station in Europe. Its daily passenger number amounts to over 300.000. Structures built for such a large number of people require a high-level safety standard. The station was built on the inner city site of the historic Lehrter Bahnhof. The conditions for building and start of operation were challenging by several reasons. The typical sandy ground with a high level of groundwater makes the permanent static stability of such a complex structure difficult. Several completed, ongoing, and planned construction activities in the immediate vicinity of the station influence the ground settlement of the whole area. On basis of the structural design an impact prediction was calculated, which expected certain vertical displacements particularly between the single columns of the outer concrete bridges of the building. These columns support the glass roof construction, which only allows a defined limit of displacement. In order to avoid damage, a concept for monitoring and adjusting potentially occurring displacements was developed for installation at the outer bridges of the station.
With more than 180.000 engineers and scientists VDI Association of German Engineers and VDE Association for Electrical, Electronic & Information Technologies are belonging to the major technical and scientific associations in Europe. Both organizations promote the advancement of technology and among other things by developing recognized technical regulations as national and international standards. Since 2011 Technical Committee 2.15 Optical Measuring Methods for Structure Analysis and Monitoring as a common committee of both organizations is working among other things on the development of standards for optical measuring and testing methods. The committee consists of 27 members representing industrial users, system manufacturers, research institutes and universities. Currently the committee is drafting the new standard VDI/VDE 2626 Part 1 - Optical measuring procedures – Image correlation methods – Basics and equipment, which will be introduced in this presentation.
Draft VDI/VDE 2626 Part 1 describes practical acceptance and reverification procedures for the evaluation of the accuracy of optical measuring systems based on digital image correlation (DIC) methods. The document applies to DIC measurement systems used a) for full-field determination of two- or three-dimensional displacement of surfaces, and b) for
full-field determination of the elongation or strain of surfaces. The standard describes quality parameters as well as methods and reference objects for their determination. The quality parameters serve to specify DIC systems, and to compare different systems. They are equally suitable a) for acceptance tests as well as b) for reverification of DIC systems within the framework of a quality management system.
The acceptance test is used to determine whether the DIC system complies with the quality parameter limits specified by the manufacturer, or with contractually agreed limits by the manufacturer and user, respectively. For this test the quality parameters zero-displacement error, zero-strain error, and displacement error are defined and used. Zero-displacement error and zero-strain error describe minimum measurement uncertainties of the DIC system a user has to reckon with. They are influenced by different uncertainty contributions. The quality parameter displacement error is used to check the ability of the DIC system to determine absolute displacements within the measurement volume and to confirm the traceability of this measurement to the SI system.
Reverification of DIC systems serves to ensure long-term compliance with specified limits for the quality parameters. By comparing the results of successive reverification measurements of the quality parameters used for the acceptance test, it is possible to analyze trends with respect to changes in DIC system characteristics.
Piezoresistive accelerometers use a strain-sensing element, generally made of semiconductor material, e.g., silicon to convert the mechanical motion into an electrical signal. This element is usually designed in form of a cantilever beam loaded with a mass. Acceleration causes bending of the beam, which produces a change of electrical resistance proportional to the applied acceleration.
Main advantages of piezoresistive accelerometers in comparison to other types, e.g., piezoelectric and capacitive, is their robust and highly dynamic behavior, which qualifies them for application in high impact shock applications. Mechanical damping is typically implemented with silicon oil in a way that the output signal is undistorted over a wide frequency range. These characteristics principally qualify them for the application in drop tests carried out at BAM, for which they are calibrated over the frequency range from 1 to 4 kHz. However, using silicon oil for damping, has the drawback of temperature dependent change of its viscosity, leading to temperature dependent deviation of the accelerometer’s sensitivity.
This study presents experimental results of the temperature behavior of a piezoresistive accelerometer with a dynamic range up to ±5000 g.
This type of accelerometer is applied for drop tests which are partially performed at temperatures of -40 or +100 °C.