Filtern
Erscheinungsjahr
Dokumenttyp
Sprache
- Englisch (16)
- Deutsch (4)
- Mehrsprachig (1)
Referierte Publikation
- ja (21) (entfernen)
Schlagworte
- Monitoring (2)
- Polymer optical fiber (2)
- Additive Manufacturing (1)
- Ageing (1)
- Aging (1)
- Application (1)
- Ausgleichsrechnung (1)
- Bauwerk (1)
- Brillouin scattering (1)
- Brillouin-Streuung (1)
- Characterisation (1)
- Chemiluminescence (1)
- Chemiluminescence (CL) (1)
- Construction (1)
- Curve fitting (1)
- Damage (1)
- Damage detection (1)
- Damage detection of bridges (1)
- Degradation (1)
- Dehnungssensor (1)
- Digital image correlation (DIC) (1)
- Digitale Bildkorrelation (DIC) (1)
- Distributed sensor (1)
- Drop test (1)
- Dynamic testing (1)
- Dynamische Tests (1)
- Elementanalytik (1)
- Environment (1)
- Ergebnisunsicherheit (1)
- FBG sensors (1)
- Faseroptischer Sensor (1)
- Fatigue (1)
- Fiber bragg grating (1)
- Fiber optic sensor (1)
- Fiber-optic sensor (1)
- High speed stereo photogrammetry (1)
- In-situ Process Monitoring (1)
- Intelligentes Geotextil (1)
- Kalibrierlösungen (1)
- Lagrange multiplier (1)
- Lagrange multiplier test (1)
- Lagrange-Multiplikator (1)
- Magnetic field (1)
- Magnetostrictive metal coating (1)
- Measurement reliability (1)
- Messunsicherheit (1)
- Non-destructive Materials (1)
- Numerical simulation (1)
- Optical digitization (1)
- Optical transmission stability (1)
- Polymer optical fibers (POFs) (1)
- Polymeroptische Faser (1)
- Process development (1)
- Safety (1)
- Schadensfrüherkennung (1)
- Schädigung (1)
- Self-diagnostic fiber optical sensor (1)
- Smart geotextiles (1)
- Spannungs-Dehnungs-Kurve (1)
- Split Hopkinson pressure bar (SHPB) (1)
- Standard (1)
- Standardisation (1)
- Steel sheet container (1)
- Strain (1)
- Strain sensor (1)
- Stress-strain curve (1)
- Structural health (1)
- Structural health monitoring (1)
- Temperature (1)
- Textile-reinforced composites (1)
- Thermo-oxidative stability (1)
- Transparency (1)
- Verteilter Sensor (1)
- Werkstoffprüfmaschinen (1)
- Zugprüfung (1)
- Zustandsüberwachung (1)
Organisationseinheit der BAM
- 4 Material und Umwelt (1)
- 4.2 Material-Mikrobiom Wechselwirkungen (1)
- 5 Werkstofftechnik (1)
- 5.1 Mikrostruktur Design und Degradation (1)
- 5.2 Metallische Hochtemperaturwerkstoffe (1)
- 5.4 Multimateriale Fertigungsprozesse (1)
- 8 Zerstörungsfreie Prüfung (1)
- 8.3 Thermografische Verfahren (1)
- 8.5 Röntgenbildgebung (1)
- 9 Komponentensicherheit (1)
The thermo-oxidative stability of commercially available polymer optical fibers (POFs) and their components (cores and claddings) was investigated. All the bare POFs (core and cladding only) studied here were based on poly(methyl methacrylate) (PMMA) core. The fibers were exposed to 100 °C/low humidity for about 4200 h. Chemiluminescence (CL) technique was applied to investigate the thermo-oxidative stability and for measuring the transmission loss during exposure a prototype device called multiplexer was used. POFs exhibited variation in thermo-oxidative stability although they possessed identical core material PMMA. This was due to difference in the chemical compositions of claddings. Claddings were more susceptible to the thermo-oxidative degradation compared to cores. The thermo-oxidative degradation of both the cladding and the core was found in POFs as a result of climatic exposure. POFs showed an early drop-off followed by a slow decline of transmission. The early drop-off of transmission was attributed to physical changes like thermal expansion and the slow decline of transmission to chemical changes like oxidative degradation of POFs. A good linear relationship between optical transmission stability and thermo-oxidative stability of POFs was established from these studies.
An der BAM wurde Anfang 1996 die GUM-konforme Ermittlung und Angabe der Unsicherheit quantitativer Prüfergebnisse eingeführt. Nach einem kurzen Überblick über die wesentlichen Schritte und die bisherigen Erfahrungen wird die Ermittlung der Unsicherheit an Beispielen aus zwei Schwerpunktsbereichen der Prüftätigkeit der BAM vorgestellt: atomspektrometrische Analyse anorganischer Materialien und mechanisch-technologische Werkstoffprüfung. Abschließend wird ein Ausblick auf die Ermittlung der Unsicherheit qualitativer Prüfergebnisse gegeben. Diese Arbeit ist ein ergänzender Beitrag zur Thematik des tm-Sonderheftes über GUM-konforme Auswertung von Messungen, das im Januar 2001 erschienen ist.
At BAM, GUM-compliant evaluation and expression of uncertainty for quantitative test results was introduced in early 1996. After a brief overview of essential steps and experience so far, uncertainty evaluation is presented for examples from two main fields of BAM´s testing activities: analysis of inorganic materials by atomic spectrometry and mechanical materials testing using tensile/compression testing machines. Finally, an outlook is given on the evaluation of uncertainty for qualitative test results. This paper is a supplementary contribution to the topic of the tm special edition on GUM-compliant evaluation of measurements published January 2001.
Embedded conventional fibre Bragg grating (FBG) sensors with acrylate coating have been chosen for monitoring novel textile-reinforced composite materials with a complicated wavy structure as a result of reinforcing textures. Problems of monitoring this type of material occur due to the harsh fabrication technology of the composite and its complicated structure. Embedded fibre sensors are exposed to the influence of transverse and point-wise deformations. To what extent will these effects influence the measurement signal of a sensor? Temperature cycles, tension and vibration tests were carried out to answer this question. Transverse and point-wise deformation and micromechanical indentation tests on non-embedded FBG sensors were carried out to clarify the reliability of recorded signals.
Detecting spreading damage in bridges is a demanding task for engineers today when the ageing infrastracture of industriaiized countries is degradating more and more. To successfully deal with tbis problem, a really advanced method has been elaborated basing on Langrange Multiplier (LM) tests and following the principle of simplicity by Hilbert and extending comments by Helmholtz refering to a combination of measurement and analytical treatment. Finally, an easy mathematical fonnation has been created.
The Split Hopkinson Pressure Bar (SHPB) is a materials testing apparatus primarily designed for the analysis of viscoplastic material behavior at very high strain rates.
Because of its complexity it is common practice to simplify the underlying exact mechanical theory by making strong assumptions. On the one hand this has to be done to achieve any results at all on the other hand one commits systematic errors. Therefore we utilize different numerical and Simulation methods to analyze and minimize these errors.
The Split Hopkinson Pressure Bar (SHPB) is a method for material characterization which works at strain rates from 102 - 104 1/s. This method can be used for example in the field of military engineering, in the field of deformation technology, automobile indurstry, aerospace industry or in other industrial fields. Controlled tests with the SHPB device enable Information about the dynamic material deformaion behaviour in the named strain rate area. The setup of the SHPB is not standarized and the measurement principle is dependent on simplifications. Due to this amongst others the problem with the dispersion of the measurement signal occurs. Furthermore it is possible that measurement uncertainties appear caused by the misalignment of the SHPB setup. In this work the influence of the alignment and a dispersion correction by pulse shaping is presented. On the one side for the alignment calibration tests are done. And on the other side for the dispersion influence correction with pulse shaping tests are done with TiA16V4. This material was choosen due to the fact that it can be compared with existing literature data.
Fiber optic sensors have gained increasing importance in recent years and are well established in many areas of industrial applications. In this paper, we introduce a concept of a self-diagnostic fiber optic sensor. The presented sensor is to resolve the problems of embedded fiber optic sensors in complex structures and to enable the validation under operational conditions. For this purpose, different magnetostrictive coated fiber optic sensors were developed and various experiments were performed to verify their mode of operation and to determine the respective reproducibility. The measuring principle is illustrated by obtained experimental results, which showed a change in wavelength from 1 pm at a magnetic field strength change of 0.25 mT. In addition, the temperature characteristics of the implemented magnetostrictive sensor were analyzed and an experimental factor of 1.5 compared to a reference fiber optic sensor was determined.
Eine gleich bleibend effektive Nutzung von Anlagen, Rohstoffen und Energie in Verbindung mit der optimalen Prozessführung sind die wichtigsten Voraussetzungen für globale Wettbewerbsvorteile der Prozessindustrie.
Unternehmen aus den Bereichen Chemie, Pharmazie, Petrochemie, Gasverarbeitung, Lebensmittel-, Zellstoff-, Papier-, Glas-, Stahl- und Zementherstellung sowie ihren Zulieferern haben den Einsatz zuverlässiger Prozessautomation für eine gute Prozessführung erkannt. Überlegene Verfahren stützen sich zunehmend auf prozessanalytische Messtechnik zur Kontrolle und präventiven Sicherstellung der geforderten Produktqualität. Gleichzeitig ermöglicht sie eine ständige Verbesserung des Wissens über den Prozess und erhöhen die Prozess- und Anlagensicherheit.