Quantitative NDE methods play a key role when it comes to inspect components,
which requires high operational safety. UT-SAFT is one of the well-known reconstruction tools,
which provides information about the defect size. In this work we studied the use of phased array
technique in combination with the SAFT algorithm to inspect power plant components. As a first
example we inspected a real-sized mock-up model representing a part of a reactor pressure vessel with
a 180 mm-thick ferritic base material followed by a 6 mm-thick austenitic cladding layer. The phased
array probe was coupled at the outer ferritic surface. We detected and sized fatigue cracks within the
cladding with a depth ranging from 4 mm to 10 mm. Secondly, we investigated a mock-up model
resembling a nozzle including a thermo sleeve inlet and a maximum wall thickness of about 37 mm.
Artificially inserted notches with a depth of 3 mm could be detected and sized, where the thermo
sleeve is welded at the inside of the nozzle.
Angeregt durch experimentelle Arbeiten zur hochauflösenden Ultraschallprüfung mit fokussierenden Prüfköpfen wird mit Hilfe von Modellrechnungen der Einfluss verschiedener Schallfeld- und Reflektorparameter auf die Echohöhe untersucht. Von besonderem Interesse ist dabei das Verhalten typischer Testreflektoren wie der Kreisscheibenreflektor und die Querbohrung in "verformten" Schallfeldern, die durch Bauteilkrümmungen und Fokussierung entstehen können. Für solche Fälle lassen sich Abstandskurven (DAC) für verschiedene Reflektortypen rechnerisch erstellen und der experimentelle Aufwand erheblich reduzieren. Ein deutlicher Fortschritt wurde durch die Weiterentwicklung des Schallfeldmodells erreicht, das insbesondere für die Entwicklung neuer Typen von Gruppenstrahlerprüfköpfen unverzichtbar ist. Die Gültigkeit des Modells wird durch bisherige Messergebnisse bestätigt.
For in-service inspections on wheelset axles with a hollow drilling, mechanized ultrasound inspection systems with single element probes are typically used. The ultrasonic testing in the zones close to the external surface of the railway axles can be realized from the inside of the bore hole, without demounting the wheelset and without dismantling the wheels and the brake discs. The testing system must be able to find flaws in the external surface of the hollow shafts, whose surface lies in the radial-radial plane, these are called transversal flaw. Presently testing systems are used, where scanning is realized in the circumferential direction by mechanical rotation of the probe system in the actual drilling. The phased array probe system, which is presented here, can carry out the rotation scan electronically. The scan can be carried out by simply moving the system forward and backwards through the drilling without mechanical rotation. Manipulation becomes simpler and the inspection time can be shortened considerably. The ultrasonic beam can be inclined exactly and be focused in the plane vertical to the specimen axis.
The probe is designed with help of indispensable simulations using especially designed software developed by BAM. The feasibility and the alignment between the simulated and experimental results were shown in earlier projects reported by Boehm et al. (2006) and Völz et al. (2012). The main task here is to optimize a probe for bore holes with a diameter of 65 mm with an increase in sensitivity and a high spatial resolution. This development will be carried out by use of extensive simulations and result in certain changes of the relevant probe parameters.
Up to now there is no sufficient technique to detect transverse cracks in austenitic and dissimilar welds which recently are of increasing interest in the integrity surveillance of nuclear power plants as well as in quality control of longitudinally welded pipes. Weld inspection by interpretation of single A-scans will lead to erroneous results due to effects caused by anisotropy and in worst case might leave flaws undetected. Therefore, imaging techniques such as the synthetic aperture focusing technique (SAFT) should be used. If the SAFT algorithm is applied on data taken from austenitic welds, the inhomogeneous, anisotropic structure of these welds has to be taken into account in order to properly attribute amplitudes measured in A-scans to the corresponding coordinates in the region of interest. While this has been investigated in the past, all attempts so far were limited to the imaging of longitudinal cracks which requires a less complicated setup than the imaging of transverse cracks. In this paper we give an outline of our attempts to reconstruct images of transverse cracks in different welds. For this purpose a SAFT program based on ray tracing and a layered structure weld model derived from an empirical model of grain orientations in welds are used. The results of the image reconstruction on experimental data are shown and compared to images obtained by assuming an isotropic homogeneous model. Root reflection and crack tip echo are clearly visible which allows an estimation of size and position of the crack with good accuracy.
Matrix phased array probes are becoming more prominently used in industrial applications. The main drawbacks, using probes incorporating a very large number of transducer elements, are needed for an appropriate cabling and an ultrasonic device offering many parallel channels. Matrix arrays designed for extended functionality feature at least 64 or more elements. Typical arrangements are square matrices, e.g., 8 by 8 or 11 by 11 or rectangular matrixes, e.g., 8 by 16 or 10 by 12 to fit a 128-channel phased array system. In some phased array systems, the number of simultaneous active elements is limited to a certain number, e.g., 32 or 64. Those setups do not allow running the probe with all elements active, which may cause a significant change in the directivity pattern of the resulting sound beam. When only a subset of elements can be used during a single acquisition, different strategies may be applied to collect enough data for rebuilding the missing information from the echo signal. Omission of certain elements may be one approach, overlay of subsequent shots with different active areas may be another one. This paper presents the influence of a decreased number of active elements on the sound field and their distribution on the array. Solutions using subsets with different element activity patterns on matrix arrays and their advantages and disadvantages concerning the sound field are evaluated using semi-analytical simulation tools. Sound field criteria are discussed, which are significant for non-destructive testing results and for the system setup.
Ultrasound propagation in inhomogeneous anisotropic materials is difficult to examine because of the directional dependency of elastic properties. Simulation tools play an important role in developing advanced reliable ultrasonic testing techniques for the inspection of anisotropic materials particularly austenitic cladded materials and dissimilar welds. A 2-D Ray tracing method is developed for evaluating ray path, amplitude and travel time for three wave modes namely quasi longitudinal wave (qP), quasi shear vertical wave (qSV) and shear horizontal waves (SH) in anisotropic materials such as austenitic cladded materials. The inhomogenity in the anisotropic material is represented by discretizing the anisotropic region into several homogeneous layers. The ray paths are traced during its propagation through the various interfaces between those layers. At each interface the problem of reflection and refraction is solved. The ray amplitudes are computed by taking into account the directivity and phase relations. Ray divergence variation and ray transmission coefficients at each refraction boundary are considered. The Ray tracing results for ultrasonic field profiles in austenitic cladded materials are validated quantitatively by 2-D Elastodynamic Finite Integration Technique (EFIT) results and by the experiments.
Die Gefährdung durch Pipelines ist in der Öffentlichkeit wegen zahlreicher Berichte über Unfälle weitgehend präsent. Warum? Weil jeder Unfall die Gefahr von massiven Umweltschäden mit sich bringt und bei Leitungen, die durch besiedeltes Gebiet führen, sogar mit menschlichen Opfern verbunden sein kann. Thema dieses Beitrags ist ein neuartiges Ultraschall-Verfahren, das eine schnellere, sichere und kostengünstigere Prüfung derartiger Rohrleitungssysteme erlaubt.
We present a generalized analytical model of thermo-acoustic sound generation based on the analysis of thermally induced energy density fluctuations and their propagation into the adjacent matter. The model provides exact analytical prediction of the sound pressure generated in fluids and solids; consequently, it can be applied to arbitrary thermal power sources such as thermophones, plasma firings, laser beams, and chemical reactions. Unlike existing approaches, our description also includes acoustic near-field effects and sound-field attenuation. Analytical results are compared with measurements of sound pressures generated by thermo-acoustic transducers in air for frequencies up to 1 MHz. The tested transducers consist of titanium and indium tin oxide coatings on quartz glass and polycarbonate substrates. The model reveals that thermo-acoustic efficiency increases linearly with the supplied thermal power and quadratically with thermal excitation frequency. Comparison of the efficiency of our thermo-acoustic transducers with those of piezoelectric-based airborne ultrasound transducers using impulse excitation showed comparable sound pressure values. The present results show that thermo-acoustic transducers can be applied as broadband, non-resonant, high-performance ultrasound sources.
The Synthetic Aperture Focusing Technique (SAFT) is an algorithm applied in non-destructive ultrasonic testing which provides an image of flaws within a specimen. The image is reconstructed from A-scans measured at different positions. Reliable evaluation of the images obtained by the SAFT-algorithm, however, depends on the representation of the reconstructed data, which is initially given in terms of positive and negative local values only. A suitable way of processing this data for evaluation is to calculate the envelope, which can be achieved by means of the analytic signal. The extension of this concept to the multidimensional case is neither trivial nor unique and although extensive work on this subject has been carried out in the past, a correct envelope calculation in multidimensional data remains difficult since it depends on an additional condition, namely the separability of the signal. In this paper, the concept of analytic signals with single-quadrant spectra is applied to process 2-dimensional data obtained by the SAFT-algorithm. Furthermore, we present a procedure to overcome the limitations of that approach by selecting local magnitude values from a number of rotated frames after evaluating the signals separability in each frame, which is briefly validated against synthetic and experimental data.