A novel direct sampling ionization scheme for ambient mass spectrometry is presented. Desorption and ionization is achieved by a quasi-continuous laser induced plasma in air. Since there are no solid or liquid electrodes involved the ion source does not suffer from chemical interferences or fatigue originating from erosive burning or from electrode consumption. A laser plasma was ignited under ambient conditions in front of a modified TOF MS atmospheric pressure interface, using a high repetition rate DPSS laser operating at 532 nm and 26 kHz and an aspherical lens with a focal length of 8 mm. Emission spectroscopy (40-1100 nm) and time resolved studies on specific plasma parameters revealed insight into the physical and chemical plasma properties. Plasma ignition can be performed in rare gases and under ambient conditions. The hot plasma zone was kept at a certain distance from the sample region. Thus, effective collisional cooling seemed to prevent thermal fragmentation. Every single spark generates a shockwave, providing new reactive species, which expands concentrically from the hot region. Under ambient conditions primary charge carriers (ions and electrons) as well as VUV radiation initialize reaction cascades equivalent to other ambient ionization methods, such as DART or DBD. Mass spectra of polar/nonpolar hydrocarbons, sugars, pharmaceuticals and natural biomolecules in food were observed. Comprehensive emission spectroscopic measurements and time resolved electron current studies revealed insight into some plasma properties, such as the emitted high energetic radiation and the time evolution of the expanding plume.
A versatile ionization scheme for atmospheric pressure MS is presented. It is based on a quasi-continuous laser-induced plasma (LIP), generated by a 26 kHz pulsed DPSS-laser, which is ignited in front of the MS inlet. Analytes are determined with different sampling regimes, comprising either an ambient desorption/ionization mechanism, a liquid-phase or gas-phase sample introduction.
The MS signal closely resembles the ionization behavior of APCI-like plasma-based sources, such as DBD or DART. Though LIPs are known to efficiently atomize/ionize any sample material, mass spectra of intact molecular ions are recorded, exhibiting low fragment-ion content. To understand this contradictory behavior, the plasma properties are investigated that lead to the formation of molecular ions. Comprehensive studies include optical emission spectroscopy, shadowgraph imaging and mass spectrometry diagnostics.
The results show that the ionization of analyte does not occur in the plasma itself, but in the cold adjacent gas layer. The pulsed character of LIPs induces an expanding shockwave, which concentrically expands around the plasma core and sweeps the molecules toward the plasma edges, where they are ionized either directly by the self-emission of the hot core or via interaction with secondary reactants. However, this unidirectional transport causes a rarefaction inside the plasma center, which leads to a decrease in plasma intensity and number density. Thus, a restoration of the former gaseous medium by other dynamically equilibrated diffusion processes would be favorable. Besides gas replenishing, we demonstrate the beneficial use of an acoustical standing wave inside an ultrasonic resonator on the performance of the LIP.