Filtern
Erscheinungsjahr
Dokumenttyp
Schlagworte
- Boden (10)
- Eignungsprüfung (8)
- MKW (8)
- Gesamtcyanid (7)
- PAK (7)
- Spurenelemente (7)
- Soil (6)
- PAH (5)
- Proficiency testing (5)
- TPH (5)
- Trace elements (5)
- Total cyanide (4)
- Ringversuch (3)
- Abfall (2)
- Interlaboratory comparison (2)
- AOX (1)
- Akkreditierung (1)
- Aniline (1)
- Biotests (1)
- Bulk material (1)
- Chemometrics (1)
- Chloroanilines (1)
- Chrom(VI) (1)
- Chromium(VI) (1)
- Copper-contaminated wood (1)
- Eingnugsprüfung (1)
- Eluates (1)
- Europäische Normung (CEN) (1)
- GC-FID (1)
- Gaschromatographie (1)
- Gaswork contaminated soil (1)
- Groundwater (1)
- ICP-MS (1)
- ICP-OES (1)
- Kompetenzbewertung (1)
- Methylanilines (1)
- Microplastics (1)
- Mineralölkohlenwasserstoffe (1)
- Municipial waste incineration ash (1)
- PCB (1)
- PLS-DA (1)
- Phosphous recovery (1)
- Photometric P determination (1)
- Proficiency Testing (1)
- Proficiency test (1)
- Qualitätsmanagement (1)
- Raman spectroscopy (1)
- Referenzmaterialien (1)
- Schwermetalle (1)
- Sewage sludge (1)
- Umweltanalytik (1)
- Ökotoxikologie (1)
Organisationseinheit der BAM
Due to the increasing presence of microplastic particles (MP) in the Environment and the unknown risks arising from them, there is an urgent need for analytical methods that allow for an efficient identification and quantification of microplastics (MP), i.e. particles < 5 mm, in environmental samples. So far, mostly timeconsuming (micro) infrared or micro-Raman spectroscopic methods are applied. Here an faster alternative Approach is presented based on a Raman processspectrometer with fiber-optical probes in combination with multivariate data analysis.
Präsentation der Ergebnisse eines Ringversuchs zur Kompetenzbewertung von Prüflaboratorien auf dem Gebiet der anorganischen und organischen Bodenanalytik: Polyzyklische aromatische Kohlenwasserstoffe (PAK) in Boden, Mineralölkohlenwasserstoffe (MKW) in Boden, Elemente in Sediment und Gesamtcyanid in Boden.
An interlaboratory comparison for the determination of aniline, nine methylated anilines and chlorinated anilines in contaminated groundwater (each compound between 1 µg L-1 and 750 µg L-1) was conducted as proficiency test for the selection of contract laboratories for a groundwater monitoring campaign. For the 13 participants, two different test sample series were prepared from a stabilized real case groundwater. Series A was the groundwater as sampled in the field and series B was prepared from series A by spiking with selected anilines. Homogeneity and stability investigations revealed that contaminated groundwater provides a viable basis for the preparation of ring test samples for the determination of anilines. Analytical procedures were limited to the standardized liquid–liquid extraction or solid-phase extraction in combination with gas chromatography/mass spectrometry (DIN 38407-16:1999). The robust consensus values were evaluated according to the standardized protocol of DIN 38402-45:2013. Robust reproducibility standard deviations ranged largely between 20?% and 60?% depending on the analyte. The proficiency assessment of individual participants combined the qualitative aspect of correct peak identification with the quantitative determination of individual concentrations within set limits in a unified approach. It could be shown that the accreditation status of laboratory and the existence of a standardized analytical procedure do not substitute a problem-related proficiency assessment of potential contractors.