Filtern
Erscheinungsjahr
Dokumenttyp
Referierte Publikation
- ja (36) (entfernen)
Schlagworte
- Brominated flame retardant (4)
- Chiral separation (3)
- Extraction (3)
- Gas chromatography (3)
- HPLC-MS/MS (3)
- Analysis (2)
- Breath (2)
- Diastereomers (2)
- Flame retardant (2)
- GC-MS (2)
- Groundwater (2)
- Hydroxylation (2)
- Mass spectrometry (2)
- Phenols (2)
- Proficiency testing (2)
- Reference materials (2)
- Sampling (2)
- Solid phase microextraction (2)
- Summation parameter (2)
- Volatile organic compounds (2)
- Volatilome (2)
- A549 (1)
- APCI (1)
- Absolute configuration (1)
- Acrylamid (1)
- Active sampling (1)
- Alcohol marker (1)
- Anomalous dispersion (1)
- Anomeric configuration (1)
- Benzenes (1)
- Bioaccumulation (1)
- Bioisomerization (1)
- Biomarkers (1)
- Bleaching (1)
- Bromierte Falmmschutzmittel (1)
- Calibration (1)
- Cancer (1)
- Certification (1)
- Certified reference materials (1)
- Combustion (1)
- Contaminated site (1)
- Contamination (1)
- Crystal structures (1)
- Cysteic acid (1)
- Cytochrom (1)
- Cytochrome P450 (1)
- Cytochromes (1)
- D-Glucuronic acid derivates (1)
- Derivatisierung (1)
- Derivatization (1)
- Detection dog (1)
- Enantiomer fraction (1)
- Enantiomer-specific bioaccumulation (1)
- Enantiomer-specific determination (1)
- Enantiomeric fraction (1)
- Enantiomers (1)
- Equivalence (1)
- Equivalent carbon number (1)
- Ethyl glucuronide (1)
- European Reference Material (1)
- External quality management (1)
- Fish feeding experiment (1)
- Flame ionization detection (1)
- Fortification (1)
- Fuel (1)
- Furfurals (1)
- GC-AED (1)
- Gasoline (1)
- Groundwater monitoring (1)
- HBCD (1)
- HPLC (1)
- HPLC-DAD (1)
- HPLC-ESI-MS/MS (1)
- HPLCMS/MS (1)
- Hair (1)
- Hair testing (1)
- Hexabromcyclododecan (1)
- High resolution NMR (1)
- High-throughput analysis (1)
- Homogeneity (1)
- Honey bees (1)
- Hydrochar (1)
- Interlaboratory study (1)
- Ion chromatography (1)
- Isoleucin (1)
- Kinetics (1)
- LC-MS (1)
- Liquid chromatography (1)
- Long term stability (1)
- Lung cancer (1)
- Marker (1)
- Measurement uncertainty (1)
- Metabolism of HBCD (1)
- Metaboliten (1)
- Methane (1)
- Method development (1)
- Method validation (1)
- Micropulverization (1)
- Micropulverized extraction (1)
- Odour discrimination task (1)
- Optical rotation (1)
- Organic pollutants (1)
- Organohalogen compounds (1)
- Oxidation (1)
- PCB (1)
- Passive sampling (1)
- Phase I metabolism (1)
- Predicting sites of metabolism (1)
- Process water (1)
- QM (1)
- Rearrangement (1)
- Remediation (1)
- Sediment (1)
- Sewage sludge (1)
- Simulation (1)
- Sniffer dogs (1)
- Stabilisation (1)
- Standardisation (1)
- Static headspace (1)
- Synthesis (1)
- Synthetic air (1)
- TBBPA-dbpe (1)
- Total organic carbon (1)
- Total petroleum hydrocarbons (1)
- Trichloroethene (1)
- VOC (1)
- Vinyl chloride (1)
- Waste (1)
- X-ray analysis (1)
- dog training (1)
- herbs (1)
- reference materials, (1)
- scent dog (1)
- smell (1)
- training model (1)
Organisationseinheit der BAM
Hexabromocyclododecane enantiomers: microsomal degradation and patterns of hydroxylated metabolites
(2011)
The degradation of the enantiomers of α-, β-, and γ-hexabromocyclododecane (HBCD) by phase I metabolism was investigated using induced rat liver microsomes. HBCD isomers were quantified using HPLC-MS/MS (ESI-) after separation on a combination of a reversed phase and a chiral analytical column. The degradation of all six isomers followed first-order kinetics and the estimated half-lives ranged from 6.3 min for both β-HBCD enantiomers to 32.3 min in case of (+)-γ-HBCD. (+)-α- and (–)-γ-HBCD displayed significantly shorter half-lives than their corresponding antipodes. It could be shown that this degradation led to a significant enrichment of the first eluting enantiomers (–)-α- and (+)-γ-HBCD. Individual patterns of mono- and dihydroxylated derivatives obtained from each α- and γ-HBCD enantiomer were seen to be distinctly characteristic. The patterns of monohydroxylated HBCD derivatives detected in liver and muscle tissues of pollack, mackerel and in herring gull eggs were largely similar to those observed in the in vitro experiments with rat liver microsomes. This enabled individual hydroxy-HBCDs to be assigned to their respective parent HBCD enantiomers.
The design and operation of an observational study on the profiles of volatile organic compounds (VOC) in the breath of 37 lung cancer patients and 23 healthy controls of similar age is outlined. The necessity to quantify each VOC considered as potential disease marker on basis of individual calibration is elaborated and the quality control measures required to maintain reproducibility in breath sampling and subsequent instrumental trace VOC analysis using SPME-GC-MS over a study period of 14 months are described. 24 VOC were quantified on basis of their previously suggested potential as cancer markers. The breath concentration levels of aromatic compounds was expectedly increased in smokers while lung cancer patients displayed significantly increased levels of oxygenated VOC such as aldehydes, 2-butanone and 1-butanol. Though sets of selected oxygenated VOC displayed sensitivities and specificities between 80 and 90% using linear discriminant analysis with leave-one-out cross validation the effective selectivity of the breath VOC approach with regard to cancer detection is clearly limited. Results were discussed against the background of the literature on volatile cancer marker investigations and the prospects to link increased VOC levels in patients’ breath with approaches to employ sniffer dogs. Experiences from this study and the literature suggest that the current state of breath VOC based discrimination between cancer patients and healthy controls is hardly improvable. Observational studies tend to observe significant differences mostly in levels of certain oxygenated VOC but without resolution required for practical application. Any step towards practicable exploitation of VOC profile differences for illness detection would have to solve current restrictions set by the low and variable VOC concentrations. Further challenges are the technical complexity of studies involving breath sampling and possibly the limited capability of current analytical procedures to detect instable marker candidates.
HBCD stereoisomer pattern in mirror carps following dietary exposure to pure Gamma-HBCD enantiomers
(2010)
The role of matrix reference materials in the process of demonstrating the degree of equivalence of measurement results obtained from intercomparisons is outlined, reviewing exemplary selected experience gained at BAM regarding the determination of organic contaminants in environmental matrices.
The specific characteristics of reference materials employed in the process of demonstrating equivalence between laboratories in the course of proficiency testing as well as the development, comparison and validation of methods are elaborated. The demand is for series of appropriately characterised samples which are fit for the purpose and it is seen from representative examples that the utilisation of such tailor-made RM designed to tackle the specific need of an analytical problem dominates over certified matrix reference materials in this context. Concluding, the role of certified matrix reference materials in quality assurance is briefly looked at both from the users and providers points of view.
1,2,5,6,9,10-hexabromocyclododecane (HBCD), a widely used flame retardant, is an ubiquitous contaminant in
the environment. Still, only little is known about the distribution and behavior in the environment such as
bioaccumulation or biotransformation of HBCD stereoisomers. In order to investigate enrichment and possible
bioisomerization of HBCD stereoisomers, Mirror Carps were exposed to pure (+)- and (-)-γ-HBCD, randomly
sampled after a predefined specific period and subjected to enantiomer-specific determination of α-, β-, and γ-
HBCD. No evidence for the isomerization of HBCD stereoisomers was observed in Mirror Carp fillets.
A method for the determination of the novel brominated flame retardant tetrabromobisphenol A bis(2,3-dibromopropylether), 1,1'-(isopropylidene)bis[3,5-dibromo-4-(2,3-dibromo-propoxy)-benzene] (TBBPA-dbpe), was developed. Technical TBBPA-dbpe was purified and the results of a thorough physical characterisation are reported. The application of APCI-MS is discussed and the fragmentation patterns are described. Quantification of TBBPA-dbpe was done by HPLC-DAD using external calibration. The validation of the method was accomplished using sediment and sewage sludge samples spiked with defined amounts of authentic TBBPA-dbpe. The average recovery rates of TBBPA-dbpe from spiked samples ranged from 35 to 91% (sediment) and from 57 to 98% (sewage sludge) depending on the respective extraction method. Pressurised fluid extraction (PFE) and fluidised bed extraction were superior to classical Soxhlet and sonication procedures and yielded recovery rates between 90 and 98% with relative standard deviations of 2%. The limits of detection (DTC), identification (ID) and determination (DTM) using HPLC-DAD were 10, 21 and 30 ng g-1 in sediment and 22, 44 and 72 ng g-1 in sewage sludge, respectively.
Fuel contamination of soils display complex and variable hydrocarbon mixtures with different volatility and toxicity characteristics. A recently suggested headspace procedure for the structure-based quantification of volatile hydrocarbons is evaluated regarding repeatability, reproducibility, and practical robustness. Three aliphatic and three aromatic fractions covering the boiling range between 69 and 216°C were defined as summation parameters by their respective equivalent carbon number ranges. A standard mixture of 35 aliphatic and aromatic hydrocarbons was used for calibration on basis of selected mass fragments specific for the aliphatics and aromatics, respectively. Two standard soils were fortified with the standard mixture or different fuels, respectively, and submitted to the analytical procedure. Limit of detection (LOD) and limit of quantification (LOQ) were for all fractions lower than 0.1 and 0.3 mg/kg, respectively. Analyte recovery was linear up to between 20 and 110 mg hydrocarbons/kg soil depending on the fraction. Hydrocarbon recovery ranged between 80% and 110% depending on the fraction and the repeatability was typically better than 10%. Finally, the impact of extraction solvent variation, column solid-phase polarity, and alternative summation of fractions were investigated. The procedure was applied to liner samples taken from a site contaminated with aviation fuel and its practicability is discussed.
A Proof of Concept: Are Detection Dogs a Useful Tool to Verify Potential Biomarkers for Lung Cancer?
(2018)
Early and reliable diagnostic test is essential for effective therapy of lung cancer. Volatile organic compounds that are characteristic for cancer could serve as valuable biomarkers in cancer diagnosis. Both trace analytical and detection dog approaches give some evidence for the existence of such biomarkers. In this proof of concept, study dogs and trace analysis were implemented in combination to gain more information concerning cancer biomarkers. Two dogs were trained to distinguish between absorbed breath samples of lung cancer patients and healthy persons and succeeded with correct identification of patients with 9/9 and 8/9 and correct negative indications from of 8/10 and 4/10 samples from healthy individuals. A recent observational study found that breath samples from lung cancer patients showed an increase in 1-butanol, 2-butanone, 2-pentanone, and hexanal. Synthetic air samples were therefore fortified with these compounds and adsorbed to a fleece. Tested against breath samples from healthy probands, on presentation to the dogs these synthetic samples provoked an indication in three out of four samples. We were able to demonstrate that a combination of the natural nose of a dog and a trace analytic technique can be a valuable concept in the search for cancer biomarkers.
Aim: The objective of the study was to provide conclusive evidence for the effect of particle size reduction as by milling on the extractable content of ethyl glucuronide (EtG) of hair samples. Methods: A number of real case hair samples and two pooled hair materials with EtG contents in the range of 1030 pg/mg were systematically compared with regard to the extraction yield of EtG after cutting to 23 mm length and pulverization with a ball mill. After the respective treatment the samples were submitted to aqueous extraction followed by quantification of EtG using HPLC-MS/MS. Results: It was unequivocally demonstrated that milling of hair samples prior to aqueous extraction significantly increases the extractable EtG content compared with cut hair. The effect ranged between 137 and 230% and was seen to occur regardless of the extent of pulverization. Cooling of samples was not necessary to prevent partial degradation of EtG during the grinding procedure. Conclusion: The options currently employed at choice in analytical practice (cutting or milling) were seen to significantly affect the extractable amount of EtG in hair. This is suspected to influence the degree of equivalence of quantification results obtained in different laboratories as well as their respective classification of a test subject's drinking behaviour on the basis of currently recommended cut-off values.