Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (99) (entfernen)
Sprache
- Englisch (90)
- Deutsch (5)
- Mehrsprachig (3)
- Portugiesisch (1)
Schlagworte
- Concrete (99) (entfernen)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (24)
- 7 Bauwerkssicherheit (21)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (19)
- 7.4 Baustofftechnologie (11)
- 7.1 Baustoffe (8)
- 7.3 Brandingenieurwesen (4)
- 8.5 Röntgenbildgebung (4)
- 8.0 Abteilungsleitung und andere (3)
- 1 Analytische Chemie; Referenzmaterialien (2)
- 1.2 Biophotonik (2)
Paper des Monats
- ja (5)
The method requires two parallel boreholes in the specimen in which two microwave antennae can be moved. The moisture content in the material can be calculated from the microwave intensity transmitted between the two boreholes. Moisture profiles along the boreholes can be obtained by moving the antennae in steps along the length of the boreholes and taking measurements at each step.
The microwave frequencies used in the laboratory measurements ranged from 8 to 16.5 GHz in steps of 0.5 GHz. The diameters of the antennae were between 7 and 9 mm, and of the boreholes between 8 and 12 mm. The microwave method produced measurement uncertainties between 0 and 2% by volume for all the materials studied in this report.
Today's civil engineering NDT needs are for quantitative, fast to apply and easy to interpret methods. They are required on site both for evaluation of existing structures/infrastructure and for quality control in new construction. With this purpose, BAM has carried out in-situ feasibility studies, using radar, impact-echo and ultrasonic-echo methods. Two examples are given of their combined application on different railway slab–track constructions, using high frequency radar, scanning impact-echo and ultrasonic array methods. The aim was to evaluate limitations and advantages, comparability and complementarity of these methods. The on-site measurements demonstrated the possibility to investigate, with good accuracy via NDT, the bonding conditions between sleepers and slab, to locate voids and measure layer thickness. The acoustic and electromagnetic methods used, were found to be complementary.
Ultrasonic reconstruction by the synthetic aperture focusing technique (SAFT) has a great potential to image concrete elements and detect embedded objects. Its algorithm focuses ultrasonic signals received at many aperture points by coherent superposition, yielding a high-resolution image of the region of interest. Using this approach, several problems caused by the strongly inhomogeneous structure of concrete are diminished, where scattering of transmitted pulses leads to disturbing phenomena such as attenuation and structural noise. This contribution is intended to review the work of the writers on the application of SAFT reconstruction to concrete testing. First, consequences of scattering of ultrasonic waves in concrete are qualitatively explained. Then the use of SAFT is discussed in comparison to traditional A-scan and B-scan techniques. Different reconstruction algorithms and implementations are presented for one-, two-, and three-dimensional SAFT. Pulse-echo measurement systems are described, which are able to acquire large sets of data on linear and planar apertures employing single transducer, transducer array, and scanning laser Doppler vibrometer arrangements. To illustrate the application of the SAFT techniques, examples from laboratory and field experiments are described comprising imaging of back walls, tendon ducts containing faults, layers, and reinforcement in concrete elements.
New thermography systems enable the application of active investigation techniques, i.e. the observation of the cooling down process after heating the surface of a structure under investigation. Defects like voids in concrete having a different thermal diffusivity in comparison to the bulk material are visualised by different surface temperatures. The differences between temperature transient curves above sound regions and above inhomogeneities are expected to include information about the defect parameters.
Experimental investigations with impulse thermography and radar on a concrete test specimen containing voids were analysed. Radar was used to determine the depth of the voids. The influence of size and depth of the voids on the temperature transient curves was studied for different heating times. The transient curves were also fitted with a simple semi-empirical model.
Impulse-thermography has been established as a fast and reliable tool in many areas of non-destructive testing. In recent years several investigations have been done to apply active thermography to civil engineering. For quantitative investigations in this area of application, finite difference calculations have been performed for systematic studies on the influence of environmental conditions, heating power and time, defect depth and size and thermal properties of the bulk material (concrete). The comparison of simulated and experimental data enables the quantitative analysis of defects.
In impact-echo testing of finite concrete structures, reflections of Rayleigh and body waves from lateral boundaries significantly affect time-domain signals and spectra. In the present paper we demonstrate by numerical simulations and experimental measurements at a concrete specimen that these reflections can lead to systematic errors in thickness determination. These effects depend not only on the dimensions of the specimen, but also on the location of the actual measuring point and on the duration of the detected time-domain signal.
Impulse-thermography is an active method for quantitative investigation of the near surface region of various structures which has recently been applied to civil engineering. It is well suited for the detection of voids and honeycombing in concrete up to concrete covers of 10 cm and more. For quantitative analysis, a computer program for numerical simulation of the heating up and cooling down processes was developed based on Finite Differences. With this program parameter studies have been performed for investigating the influence of environmental conditions, material parameters and geometry on the thermal behaviour. The comparison between experimental and simulated results enables the Inverse Solution.
The search for durable and sustainable construction materials inspires the developments in the world of cement concrete, as well as in the world of concretepolymer composites. Both worlds recognize, strive for and accept each others contribution to the synergetic effects that are realized by the combination of classical building materials and polymers. A better knowledge of materials behaviour, especially in the field of admixtures, and a better understanding of curing processes allowed the development of highly performing mineral or modified mineral concretes, mortars and grouts. CPC-science becomes an invaluable element in the development of sustainable construction materials. ICPIC brings together practitioners and scientists, dealing with concretepolymer composites in all industrial fields, but with emphasis on construction industry. The 11th International ICPIC Congress took place in Berlin, 24th June 2004. New trends and evolutions have been presented and discussed. The highlights of the Congress, and the synergies for the construction world that emerge from this congress on polymers in concrete in combination with cement concrete, are presented.
The applicability of pulse phase thermography (PPT) for the investigation of structures is studied systematically on concrete test specimens and on a plastered sandstone column. In the test specimens, voids and delaminations are implemented in different depths and with different sizes, modelling real voids, honeycombing and debonding. Delaminations of plaster in concrete and masonry and behind tiles on concrete are investigated. PPT is based on the frequency analysis of the cooling down process of actively heated surfaces. Therefore, it is contactless and thus completely non-destructive (if overheating of the surface is prevented), fast and allows the inspection of large surface areas. The interpretation of amplitude and phase images gives semi-quantitative information about the observed defects. The phase images provide a deeper probing up to 1015 cm in relation to the interpretation of the thermograms and to the amplitude images. In addition, the influence of surface inhomogeneities and non-uniform heating is reduced.