Application of a cross correlation technique for assessment of a non-homogeneous stress field
(2016)
Many researchers have addressed the determination of a homogeneous stress field from the analysis of ultrasound waves, using the theory of acoustoelasticity with Murnaghan´s constants derived for axially loaded specimens with the ultrasound wave path also in the axial direction, or for hydrostatically loaded specimens. However, the use of such strategy for structural healthy monitoring requires the ability to handle nonhomogeneous, arbitrarily oriented stress fields. This paper describes an attempt to evaluate changes in the stress field of a concrete block with an eccentrically placed tendon through acoustoelastic analysis. Pairs of acoustic transducers are placed on the surfaces such that wave paths are parallel to the tendon. A cross correlation technique is used for the accurate assessment of the sound velocity changes, and subsequent application of Murnaghan´s equations for assessing the stress changes. Results are promising with respect to the evaluation for non-homogeneous stress field from ultra sound velocities.
Emerging infectious diseases arise as a result of novel interactions between populations of hosts and pathogens, and can threaten the health and wellbeing of the entire spectrum of biodiversity. Bees andtheir viruses area case in point. However, detailed knowledge of the ecological factors and evolutionary forces that drive disease emergence in bees and other host–pathogen communities is surprisingly lacking. In this review, we build on the fundamental insight that viruses evolve and adapt over timescales that overlap with host ecology. At the same time, we integrate the role of host community ecology, including community structure and composition, biodiversity loss, and human driven disturbance, all of which represent significant factors in bee virus ecology. Both of these evolutionary and ecological perspectives represent major advances but, in most cases, it remains unclear how evolutionary forces actually operate across different biological scales (e.g., from cell to ecosystem). We present a molecule-to-ecology framework to help address these issues, emphasizing the role of molecular mechanisms as keybottom-up drivers of change at higher ecological scales. We consider the bee–virus system to be an ideal one in which to apply this framework. Unlike many other animal models, bees constitute a well characterized and accessible multispecies assemblage, whose populations and interspecific interactions can be experimentally manipulated and monitored in high resolution across space and time to provide robust tests of prevailing theory.
This paper describes the experimental calibration of an existing Wiegmann–Polonceau roof truss based on modal parameters. Dynamic tests allowed the determination of the natural frequencies and mode shapes of the global truss and of individual truss members. The global and local modal configurations as well as coupled vibration of truss members are discussed. In addition, as truss members are axially loaded, the effect of stress stiffening on the modal parameters is considered. Moreover, several finite element models with different modelling assumptions for the details of the connections and member geometrical characteristics such as gusset plates and turnbuckles were developed. A suitable numerical model was chosen to represent the truss structural behavior. This paper focuses on the local measurement and analysis strategies applied to single truss members. The possibility of using a local analysis method, namely methods that consider individual members as part of a structure, is demonstrated to assess the behavior of the global truss structure. The comparison of the results after calibration reveals a very good correlation between the experimentally identified and numerically estimated modal parameters of the historic truss.
Flame retarded polymeric materials are used in various applications in which a certain fire behavior is demanded. Protection goals are defined, such as limited flammability in terms of hindered sustained ignition or limited contribution to a fire, and these protection levels are tested with defined specimens or components in defined fire scenarios, that is to say, different fire tests. Passing a specific fire test by meeting whatever its demands is often the most important development goal, so the parameters of the different fire tests vary widely to emphasize different fire properties. Some fire tests are used to screen or provide a general assessment of flame retardant polymers during development, while other fire tests and tailored experiments are performed to address special phenomena or understand the flame retardancy modes of action. For all fire testing, the devil is in the details – demanding know-how and crucial efforts to manage the quality of investigations and advanced interpretation. This chapter aims to offer a structured overview of all these aspects.
The ‘Gänstorbrücke’ bridge between the cities of Ulm and Neu-Ulm is one of the best-monitored bridges all over Germany. In addition to an already active bride monitoring system, we have equipped the bridge with 30 ultrasonic transducers to explore the monitoring possibilities at an in-service large-scale reinforced concrete structure with continuous active ultrasonic measurements. The monitoring system is based on the detection of small changes in the entire signal, especially the multiply scattered parts of the recording, the so-called coda. Applying Coda Wave Interferometry (CWI), subtle changes in the signal can be detected and related to changing velocities in the area between source and receiver. A comparison of the results from coda wave interferometry with the strain measurements of the permanent monitoring system shows a correlation between strain measurements and CWI results. We discuss the challenges of changing environmental conditions, pose for interpretation of the results, and highlight the advantages of embedded versus externally attached ultrasonic transducers in permanent bridge monitoring, especially when coda wave interferometry is applied.
ICP-MS is based on the formation of (preferentially monovalent positively)charged atomic ions in an inductively coupled Ar plasma at almost 10 000 K. The ions formed are transferred from the plasma source at ambient pressure into a mass Separator operated at high vacuum via a set of cones. The ions are separate«! according to their mass/charge ratio in the mass Separator (quadrupole, magnetic sector field or time-of-flight mass Separator). In most cases, the ions are detected using a secondaiy electron multiplier; in some set-ups (also) a Faraday cup can be used. Single-collector (scanning mass spectrometer usually used for quantitative elemental analysis) or multicollector (static Operation of mass spectrometer for precise isotope ratio analysis) configurations can be found.
Intermediate level waste often contains residual water or other liquids. The liquids can be decomposed due to radiolysis and can also vaporize especially under fire impact. These pressure generating processes are described. One example for the pressure determination inside a closed cask is discussed using two different approaches: analytical and CFD
Due to their simple and reliable application, elastomers are used for many tasks. Many fields of application like transport, aviation and process technology, entail low temperatures where proper functionality of the employed seals has to be ensured. Therefore, understanding the low temperature behavior of elastomeric seals is important for safe seal operation to restrict the temperature application range.
For all areas of application, the question of seal lifetime is also important for replacement or maintenance intervals. The lifetime is especially important in applications that allow no seal replacement. Since the seal can determine the lifetime of storage in such cases, reliable lifetime estimation is necessary for these applications, and requires an extensive knowledge of the specific aging behavior.
The implementation of fluorescent methods is of outstanding importance in the field of optical chemical sensor Technology and biosciences. Their bioanalytical applications are manifold including fluorescence microscopy, fluorescence in situ hybridization, DNA sequencing, fluorescence-activated cell sorting, immunoassays, analysis of DNA and Protein microarrays, and quantitative PCR, just to name a few examples. Particularly, fluorescence microscopy is a valuable method in the versatile field of biomedical imaging methods which nowadays utilizes different fluorescence Parameters like emission wavelength/Color and lifetime for the discrimination between different targets. Sectional Images are available with confocal microscopes. Tissue, cells or single cellular compartments can be stained and visualized with fluorescent dyes and biomolecules can be selectively labeled with fluorescent dyes to Monitor biomolecular interactions inside cells or at Membrane bound receptors.
On the other hand , fluorophores can act as indicator (or "molecular probe") to visualize intrinsically colorless and non-fluorescent ionic and neutral analytes such as pH, Oxygen (pO2), metal ions, anions, hydrogen peroxide or bioactive small organic molecules such as Sugars or nucleotides. Thereby, their photoluminescent properties (fluorescence or phoporescence intensity, exitation and/or Emission wavelength, emission lifetime or anisotropy) respond to the presence of these species in their immediate Environment. In general, the use of luminescent probes has the advantage that they can be delivered directly into the sample, and detected in a contactless remote mode. By now, these probes are often encapsulated in different types of nanoparticles (NPs) made from (biodegradable) organic polymers, biopolymers or inorganic materials like silica or bound to their surface.
Bio-panning is a common process involved in recombinant antibody selection against defined targets. The biopanning process aims to isolate specific antibodies against an antigen via affinity selection from a phage display library. In general, antigens are immobilized on solid surfaces such as polystyrene plastic, magnetic beads, and nitrocellulose. For high-throughput selection, semi-automated panning selection allows simul-taneous panning against multiple target antigens adapting automated particle processing systems such as the KingFisher Flex. The system setup allows for minimal human intervention for pre-and post-panning steps such as antigen immobilization, phage rescue, and amplification. In addition, the platform is also adaptable to perform polyclonal and monoclonal ELISA for the evaluation process. This chapter will detail the protocols involved from the selection stage until the monoclonal ELISA evaluation with important notes attached at the end of this chapter for optimization and troubleshooting purposes.