Recent years have seen extended use of ultrasonic techniques for concrete infrastructure assessement. They are applied for quality assurance and condition assessement at bridges, power plants, dams and other important objects. However, there are still a couple of significant limitations. They include, but are not limited to depth of penetration, imaging complex structures or early stage detections of distributed damage. The talk will give information on recent research in this area. Specifically, the application of the unique deep penetration system LAUS is shown. Ultrasonic monitoring using embedded transducers to check for subtle and sudden changes in the material is introduced as well. Comments on initiatives for validation, standardization and certification will be given.
Monitoring of Concrete with Embedded Ultrasound Sensors, Coda Waves and a Novel Measurement Device
(2020)
Using embedded ultrasound (US) sensors in civil engineering structures and Coda Wave Interferometry (CWI), DFG research group CoDA aims for developing methods of concrete damage assessment by combination of Micro and macro scale simulations and experiments. BAMs goal within the project is the provision of small and durable measurement equipment on the one hand, and the investigation of damage sensitive parameters and development of an imaging algorithm on the other hand. In this study we focus on the development of the measurement system and the influence of temperature variations on the measurements.
Entwicklung eines luftgekoppelten Ultraschall-Echo-Prüfverfahrens mittels fluidischer Anregung
(2020)
In vielen technischen Bereichen werden Ultraschallverfahren zur zerstörungsfreien Werkstoffprüfung (ZfP) eingesetzt um auf Basis der Signalstärke und der Laufzeit Einbauteile und Beschädigungen zu orten. Luftgekoppelter Ultraschall spielt bisher in kommerziellen Anwendungen vor Allem im Bauwesen eine untergeordnete Rolle, da die Differenz der akustischen Impedanzen von Luft und Festkörpern immense Verluste beim Übergang des Schallsignals hervorruft.
Im Rahmen des Promotionsvorhabens soll die Eignung eines neuartigen Anregungsprinzip untersucht werden, mit dem ein Großteil dieser Verluste vermieden werden soll. Anstelle eines Festkörpers soll mit Hilfe einer fluidischen Düse Druckluft zur Signalerzeugung eingesetzt werden. Die Impedanzverluste zwischen Aktuatormembran und Umgebungsluft entfallen daher.
Die gezielte Schallerzeugung durch einen pulsierenden Freistrahl ist weitgehend unerforscht. Es ist daher notwendig, den so erzeugten Schallpuls in der Interaktion mit dem transienten Strömungsfeld zu untersuchen. Das kompressible Medium Luft und die geringen räumlichen Dimensionen einer hochfrequenten Pulsdüse werfen darüber hinaus einige Herausforderungen hinsichtlich der eingesetzten Messtechnik auf. Hier sollen geeignete Verfahren weiterentwickelt und validiert werden, um die Eignung des fluidisch erzeugten Pulses zu überprüfen.
In diesem Vortrag werden erste Messungen an einem fluidischen Schalter mit denen an einem kommerziellen Luftultraschallprüfkopf verglichen.
Due to the high sensitivity of coda waves to the smallest structural alterations such as strain, humidity or temperature changes, ultrasonic waves are a valid means to examine entire structures employing networks of ultrasonic transducers. In order to substantiate this ex ante assessment, the viability of measuring ultrasonic waves as a valid point of reference and inference for structural changes is to be further scrutinized in this work. In order to investigate the influence of mechanical strain on ultrasonic signals, a four-point bending test was carried out on a reinforced concrete beam at Ruhr University Bochum. Thus, measurements collected from a network of selected transducer pairings arranged across the central, shear-free segment of the test specimen, were correlated to their respective strain fields. Detected ultrasonic signals were evaluated employing Coda Wave Interferometry. Such analysis comprised the initial non-cracked state as well as later stages with incremental crack depth and quantity. It was to ascertain that the test specimen can in fact be qualitatively compartmentalized into areas of compression and tension identified via Relative Velocity Changes presented in Attribute Maps. However, since results did not entail a zero crossing, i.e., neither positive nor negative values were to be calculated, only relative changes in this work displayed staggered over the height of the object under test, are discussed. Under the given methodological premises, additional information is currently required to make quantitative assertions regarding this correlation of ultrasonic and strain results. This holds true for the comparability of the ultrasonic and strain results for both non-cracked and even the cracked state.
Air-coupled ultrasound was used for assessing natural defects in wood boards by through-transmission scanning measurements. Gas matrix piezoelectric (GMP) and ferroelectret (FE) transducers were studied. The study also included tests with additional bias voltage with the ferroelectret receivers. Signal analyses, analyses of the measurement dynamics and statistical analyses of the signal parameters were conducted. After the measurement series, the samples were cut from the measurement regions and the defects were analyzed visually from the cross sections. The ultrasound responses were compared with the results of the visual examination of the cross sections. With the additional bias voltage, the ferroelectret measurement showed increased signal-to-noise ratio, which is especially important for air-coupled measurement of high-attenuation materials like wood. When comparing the defect response of GMP and FE sensors, it was found that FE sensors had more sensitive dynamic range, resulting from better s/n ratio and short response pulse. Classification test was made to test the possibility of detecting defects in sound wood. Machine learning methods including decision trees, k-nearest neighbor and support vector machine were used. The classification accuracy varied between 72 and 77% in the tests. All the tested machine learning methods could be used efficiently for the classification.
Monitoring of concrete structures is of utmost importance in maintenance and preservation of infrastructure. As a part of the DFG research group CoDA (Concrete Damage Assessment by Coda Waves), the works within this PhD project aim for identification of damage sensitive parameters extracted from ultrasonic measurements obtained with embedded sensors, the determination of environmental (reversible) influences on the signal and the localisation of damaged areas. The main technique used for the detection of changes in the monitored material is the so-called Coda Wave Interferometry (CWI). It uses the later part of the ultrasonic recording for the detection of small changes in the sensed area and the calculation of a relative velocity change. Using this technique we can show that we are able to detect changes in concrete temperature with ultrasound measurements. This enables temperature correction for ultrasound monitoring with embedded sensors. The crucial point for imaging and localisation with coda waves is the calculation of the so-called sensitivity kernels. We propose the application of numerical wave simulations for the kernel calculations instead of the commonly used diffusivity equation. Using finite-difference wave modelling code from our DFG project partners we are able to calculate those Kernels and first results are shown in this presentation. The major task for the second year will be the development and implementation of the inversion algorithm as well as the preparation of validation experiments.
Imaging wood defects using air coupled ferroelectret ultrasonic transducers in reflection mode
(2020)
Air-coupled ultrasound (ACU) is used to detect defects in wood panels without physically contacting the sample and with a quick scanning rate. Transducers made of cellular polypropylene (PP) with a high signal-to-noise ratio are quite suitable for ACU testing of wood. The extremely low modulus of elasticity and low density of PP transducers results in a small difference in acoustic impedance for the Transmission of ultrasonic waves between the transducer and air, allowing new areas of application to become possible.
To demonstrate the suitability of the reflection technique, measurements are shown on the three samples Multiplex, LVL, and MDF and compared with transmission measurements. Due to this acoustic barrier and the use of cellular PP transducers, an exact detection of delamination and cavities is possible in wood panels up to 40 mm thick. If only one side of an object is accessible and the depth of the defect is of interest, the reflection technique is preferred at the expense of a reduced measuring accuracy and Penetration depth.