A novel approach is suggested to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background signals 'backlighting' of 2D X-ray detectors. Depending on the detector geometry the mechanism may be different. Either based on the optical scattering of the fluorescent screen materials into the optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert Beer's law in single projections (radiographs) as a function of the detector area coverage and the magnitude of the attenuation. The absorption of multiple metal sheets is investigated by monochromatic synchrotron radiation, thus excluding beam hardening. The proposed correction procedure simply requires the individual subtraction of one and the same fraction of the primary and transmitted mean intensity, as a constant (non-local) scattering mechanism is assumed.
Water evolution in the gas diffusion layer of a polymer electrolyte membrane fuel cell was visualized in situ by means of synchrotron X-ray radiography. Cracks in the microporous layer were identified as start points of efficient liquid water transfer paths through the gas diffusion layer. Quantitative analysis of the water flow rate through those arbitrarily distributed cracks into the gas channel revealed that they have a strong influence on the overall liquid water transport. This could find entry into future material design and simulation.
Computer modelling of non-destructive testing methods has come a long
way from the beginnings in the mid 90s to today. Radiographic modelling for
components with higher wall thicknesses, as they are typical for nuclear
applications, must include precise predictions of scattered radiation and its impact
in terms of contrast reduction. Dedicated or general purpose Monte Carlo methods
with the ability to calculate higher order scattering events are the state of the art for
these applications. Aerospace applications, on the other hand, have stronger
requirements on the modelling code's capabilities to import complex CAD
geometries, and can benefit from faster analytical scatter models, limited to first or
second order scattering events. Similar distinctions can be made for the various
approaches proposed to accurately model geometrical and film unsharpness, film
granularity, film responses, film/foil cartridges and photon noise. This article
presents a state-of-the-art review of radiographic modelling from the perspective of
two important application domains with very different requirements, nuclear and
aerospace.