The inspection of complex-shaped components, such as those enabled by additive manufacturing, is a major challenge in industrial quality assurance. A frequently adopted approach to volumetric non-destructive evaluation is X-ray computed tomography, but this has major drawbacks. Two-dimensional radiography can overcome some of these problems, but does not generally provide an inspection that is as capable.
Moreover, designing a detailed inspection for a complex-shaped component is a labour-intensive task, requiring significant expert input. In response, a computational framework for optimizing the data acquisition for an image-based inspection modality has been devised. The initial objective is to advance the capabilities of radiography, but the algorithm is, in principle, also applicable to alternative types of imaging. The algorithm exploits available prior
information about the inspection and simulations of the inspection modality to allow the Determination of the optimal inspection configuration, including specifically component poses with respect to the imaging system. As an intermediate output, spatial maps of inspection performance are computed, for understanding spatially varying limits of detection. Key areas of innovation concern the defect detectability evaluation for arbitrarily complex indications and the creation of an application-specific optimization algorithm. Initial trials of the algorithm are presented, with good results.
Industrial radiography or Radiographic Testing (RT) is a method of non-destructive testing where many types of manufactured components can be examined to verify the internal structure and integrity of the specimen. The computer program aRTist can generate synthetic radiographs from a virtual RT test set-up. In the field of industrial radiology simulation is used, e.g. to optimize techniques for complex applications, to support the preparation of written procedures, and for education purposes.
The simulator aRTist combines analytical and Monte Carlo methods to efficiently model the radiation transport. The program comes with a graphical user interface written in Tcl/Tk. In combination of Tcl/Tk and the 3D capabilities of the visualization toolkit (VTK) a practical and convenient simulator has been realized. This will be illustrated by discussing application scenarios of classical radiography, X-ray computer tomography, and X-ray backscatter imaging. Additionally, some insight to the software implementation of the simulator will be given.
This work presents the use of limited experimental measurements to develop a set of calibrated Simulation parameters that can then be used for reliable simulation of subsea pipeline inspections. The modelling software aRTist is used as the simulation tool, and the calibration is through comparison with experimental images of a well characterised sample in a water tank. Image Quality parameters such as signal-to-noise ratio, contrast and basic spatial resolution are compared with the aim of matching simulated values to experimental results. Currently the model is partially calibrated, with signal-to-noise ratio successfully matched while differences are still found in contrast-to-noise ratio comparisons. This means that measurements depending on absolute intensity are not accurate enough in the simulation at this stage. However, the simulation is found to be accurate for wall thickness measurements in tangential images, which are not based on absolute intensity, with simulated and experimental cases producing similar results.
Computer modelling of non-destructive testing methods has come a long
way from the beginnings in the mid 90s to today. Radiographic modelling for
components with higher wall thicknesses, as they are typical for nuclear
applications, must include precise predictions of scattered radiation and its impact
in terms of contrast reduction. Dedicated or general purpose Monte Carlo methods
with the ability to calculate higher order scattering events are the state of the art for
these applications. Aerospace applications, on the other hand, have stronger
requirements on the modelling code's capabilities to import complex CAD
geometries, and can benefit from faster analytical scatter models, limited to first or
second order scattering events. Similar distinctions can be made for the various
approaches proposed to accurately model geometrical and film unsharpness, film
granularity, film responses, film/foil cartridges and photon noise. This article
presents a state-of-the-art review of radiographic modelling from the perspective of
two important application domains with very different requirements, nuclear and
aerospace.
A model is presented that employs a unified approach for
simulating the photon energy spectra for transmission and direct
beam targets composed of arbitrary homogeneous materials. In order
to achieve this, a detailed model of electron transport within the
target is employed. The validity of the developed model is shown
through comparisons with Monte Carlo simulations as well as
measurements for a number of different configurations.
Modelling becomes more and more important in modern NDE. It is increasingly used to optimize techniques for complex applications, to support the preparation of written procedures, and for education purposes. To describe the complete chain of RT, the model includes simulating all necessary properties of X- or Gamma-ray sources, the interaction of photons with material with special attention to scattered radiation, the detection process, and the complete geometrical RT setup handling arbitrary parts or constructions. Depending on the given inspection problem and the influencing factors that should be addressed by the simulation, an appropriate physical model has to be chosen to describe the underlying interaction mechanisms. The simulator aRTist combines analytical and Monte Carlo methods to efficiently model the radiation transport such that transmission as well as scatter techniques can be modelled. In this contribution we focus on Monte Carlo simulation of scatter contribution within aRTist. Examples for RT/tomographic applications and back-scatter techniques are presented to demonstrate the usability of the presented simulation tool for a broad range of radiological applications.
Modelling becomes more and more important in modern NDE. It is increasingly used to optimize techniques for complex applications, to support the preparation of written procedures, and for education purposes. To describe the complete chain of RT, the model includes simulating all necessary properties of X- or Gamma-ray sources, the interaction of photons with material with special attention to scattered radiation, the detection process, and the complete geometrical RT setup handling arbitrary parts or constructions. Depending on the given inspection problem and the influencing factors that should be addressed by the simulation, an appropriate physical model has to be chosen to describe the underlying interaction mechanisms. The simulator aRTist combines analytical and Monte Carlo methods to efficiently model the radiation transport such that transmission as well as scatter techniques can be modelled. In this contribution we Focus on Monte Carlo Simulation of scatter contribution within aRTist. Examples for RT/tomographic applications and back-scatter techniques are presented to demonstrate the usability of the presented simulation tool for a broad range of radiological applications.
The new standard ‘ISO 17636-2:2013: Non-destructive testing of welds — Radiographic testing — Part 2: X- and gamma-ray techniques with digital detectors’, defines the practice for radiographic inspection of welded pipes for manufacturing and in-service inspection. It is applied in Europe for inspections of pipe welds in nuclear power plants as well as in chemical plants and allows a faster inspection with digital detector arrays (DDA) than with film. Nevertheless, it does not allow the evaluation of the depth and shape of volumetric and planar indications. In 2001 a planar tomography scanner, TomoCAR, was introduced for mechanized radiographic testing (RT) inspection and non-destructive measurement of cross sections. The project TomoWELD is based on a new concept of the scan geometry, an enhanced GPU based reconstruction, and the application of a new generation of photon counting DDAs based on CdTe crystal CMOS hybrids. The new detector permits the selection of energy thresholds to obtain an optimum energy range and reduction of the influence of scattered radiation. The concept and first measurements are presented. Flaw depth and shape of volumetric and planar irregularities can be determined.
Radiography benchmark 2014
(2015)
The purpose of the 2014 WFNDEC RT benchmark study was to compare predictions of various models of radiographic techniques, in particular those that predict the contribution of scattered radiation. All calculations were carried out for homogenous materials and a mono-energetic X-ray point source in the energy range between 100 keV and 10 MeV. The calculations were to include the best physics approach available considering electron binding effects. Secondary effects like X-ray fluorescence and bremsstrahlung production were to be taken into account if possible. The problem to be considered had two parts. Part I examined the spectrum and the spatial distribution of radiation behind a single iron plate. Part II considered two equally sized plates, made of iron and aluminum respectively, only evaluating the spatial distribution. Here we present the results of above benchmark study, comparing them to MCNP as the assumed reference model. The possible origins of the observed deviations are discussed.