Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (56)
- Vortrag (12)
- Posterpräsentation (12)
- Buchkapitel (5)
- Beitrag zu einem Tagungsband (5)
- Beitrag zu einem Sammelband (4)
- Dissertation (4)
- Sonstiges (3)
- Forschungsbericht (2)
Sprache
- Englisch (91)
- Deutsch (11)
- Mehrsprachig (1)
Schlagworte
- Polymer (103) (entfernen)
Organisationseinheit der BAM
- 6 Materialchemie (14)
- 1 Analytische Chemie; Referenzmaterialien (12)
- 1.2 Biophotonik (8)
- 5 Werkstofftechnik (6)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (5)
- 6.6 Physik und chemische Analytik der Polymere (5)
- 5.3 Polymere Verbundwerkstoffe (4)
- 1.7 Organische Spuren- und Lebensmittelanalytik (3)
- 6.3 Strukturanalytik (3)
- 7 Bauwerkssicherheit (3)
Eingeladener Vortrag
- nein (12)
Thermoresponsive polymers have shown great potential in applications such as bioseparation, drug delivery and diagnostic. Only few thermoresponsive polymers that present an upper critical solution temperature (UCST) in a relevant temperature range, i.e. phase separate from solution upon cooling, have been reported so far. Moreover, the most studied UCST type polymers namely polybetaines are difficult to use under physiological conditions, which significantly restricts their potential applications. Therefore, UCST polymers with sharp and robust phase transition in physiological conditions (in the presence of salts, ions etc.) are highly needed in order to extend the range of applications of this class of polymers. Herein, a robust UCST-type copolymer of acrylamide (AAm) and acrylonitrile (AN) (poly(AAm-co-AN)) was prepared by reversible addition fragmentation chain transfer (RAFT) polymerization and its thermo-induced aggregation behavior in aqueous media was studied. At temperature below the UCST, the copolymer chains were aggregated together. The aggregate size was found to be larger with increasing AN contents and became smaller upon dilution of the copolymer solutions. While above the UCST, the copolymer chains were expanded and weekly associated in solution. The association between the copolymer chains formed smaller aggregates with increasing the AN contents or the dilution of the solutions. A model is proposed to explain such aggregation-association behavior of the Fig. 1.
Figure 1. Schematic illustration of the proposed thermos-induced aggregation behavior of the poly(AAm-co-AN) in aqueous solution.
Dual orthogonal functionalities in a single material is highly desirable in many fields such as bio-imaging, sensing, coating or diagnostic and therapy. However, a precise and controlled approach to prepare two different functionalities is still a challenging task. Herein, we show the simple preparation method for the synthesis of dual-functional hybrid core/shell/shell nanoparticles consisting of a silica core with a fluorescent and a thermoresponsive polymeric layer. Silica core particles were first coated by a fluorescent layer using surface- nitiated reversible addition-fragmentation chain transfer (RAFT) polymerization. The fluorescent silica nanoparticles were then completely enclosed within a switchable protective coating made of thermoresponsive poly(N-isopropylacrylamide) via RAFT polymerization. Thermoresponsive poly(N-isopropylacrylamide) is known to change its properties according to the surroundings temperature in a reversible and controllable way (LCST behavior). The successful preparation of well-defined dual-functional hybrid core/shell/shell nanoparticles was shown by scanning electron microscopy, thermogravimetric analysis and Fourier transform infrared spectroscopy, while their fluorescence and thermoresponsive properties were confirmed by fluorescence spectroscopy and dynamic light scattering measurements, respectively.
Thermoresponsive polymers have shown great potential in applications such as bioseparation, drug delivery and diagnostic. Only few thermoresponsive polymers that present an upper critical solution temperature (UCST) in a relevant temperature range, i.e. Phase separate from solution upon cooling, have been reported so far. Moreover, the most studied UCST type polymers namely polybetaines are difficult to use under physiological conditions, which significantly restricts their potential applications. Therefore, UCST polymers with sharp and robust phase transition in physiological conditions (in the presence of salts, ions etc.) are highly needed in order to extend the range of applications of this class of polymers.
Herein, a robust UCST-type copolymer of acrylamide (AAm) and acrylonitrile (AN) (poly(AAm-co-AN)) was prepared by reversible addition fragmentation chain Transfer (RAFT) polymerization and its thermo-induced aggregation behavior in aqueous media was studied by turbidity and dynamic light scattering measurements. At temperature below the UCST, the poly(AAm-co-AN) copolymer chains were aggregated together. The aggregate size was found to be larger with increasing AN contents and became smaller upon dilution of the copolymer solutions. While above the UCST, the poly(AAm-co-AN) copolymer chains were expanded and weekly associated in solution. The association between the copolymer chains formed smaller aggregates with increasing the AN Contents or the concentration of the solutions. A model is proposed to explain such aggregationassociation behavior of the poly(AAm-co-AN) copolymer depending on the AN Contents and concentration of the solutions.
Flexible, niedrigdichte Schäume aus Biokunststoffen im Extrusionsverfahren herzustellen war bisher industriell noch nicht möglich. Im Verarbeitungstechnikum Biopolymere des Fraunhofer IAP wurde in einem Projekt die Eignung von PBS-basierten Biokunststofftypen für Schaumanwendungen erforscht und weiterentwickelt.
Ablation experiments with ultrashort laser pulses (pulse duration 150 fs, wavelength 800 nm) on polymers (PC, PMMA) relevant for biomedical technology have been performed in air. The lateral and vertical machining precision was evaluated by optical, atomic force and scanning electron microscopy. The ablation threshold reaches values in the range of 0.52.5 J/cm2 and depends significantly on the number of laser pulses applied to the same spot. The hole diameters are influenced by the laser fluence and the number of laser pulses. The relation between the ablation threshold and the number of laser pulses applied to the same spot is described in accordance with an incubation model.
The pollution of marine, limnic and terrestrial environments with plastic waste and the potential impact especially on biota and humans has received increasing attention in recent years. Special focus is on particles smaller than 5 mm, the so-called microplastics. Consequently, possible regulations of emission and remediation efforts require sound information on the occurrence and fate of microplastics in the respective environmental compartments.
Microplastics (MP) differ from classical organic pollutants in biota or the environment in that they do not consist of clearly defined low-molecular weight compounds but of polymer particulates with varying sizes and chemical compositions. This leads to specific challenges regarding the analytical techniques to be employed for their identification and quantification.
Microplastics are defined as polymer particle in the size range between 1 µm and 5 mm and cover a wide range of polymers such as polyethylene, polypropylene, polystyrene and polyethylene terephthalate in variable geometric shapes. Properties relevant for environmental microplastics are polymer type, particle form and size distribution, surface morphology (aging status) and total mass fraction contained in a given sample. Polymer identification and particle size estimation using optical methods (IR and Raman spectroscopy) are time consuming and complicated by surface characteristics as a result of weathering, soiling, and microbial colonisation. Total mass fractions of MP in environmental samples can be determined by thermo-analytical methods.
There are currently no standardised methods for sampling, sampling preparation, or detection of MP in environmental samples. So far, qualitative and quantitative investigations are done by research institutes and have not reached the routine laboratory community. The near future will see harmonisation efforts of MP mass fraction determination in environmental matrices by thermo-analytical procedures.
The immediate need for reference materials during method development and comparison is outlined with regard to relevant matrix/polymer compositions, existing regulations and currently achievable detection limits. Examples for solid environmental matrix reference materials are discussed regarding the challenges encountered with matrices and polymer types as well as homogeneity testing and property value characterisation.
In order to develop simple and versatile procedures for the preparation of red emissive particles, various one-step swelling procedures for the loading of fluorophores into nanometer- and micrometer-sized polystyrene particles were systematically assessed. Parameters studied for model dyes from common dye classes include the composition of the swelling medium, dye charge and polarity, dye concentration, and particle surface chemistry. The dye loading procedures were compared based upon the efficiency of dye incorporation, fluorescence intensity, and colloidal stability of the resulting particles as well as the absence of dye leaking as determined by absorption and fluorescence spectroscopy, flow cytometry, and measurements of zeta potentials. In addition, for the first time, the influence of the amount of incorporated dye on the absolute fluorescence quantum yield and brightness of the fluorescent particles was investigated for selected chromophores in differently sized particles using a custom-made calibrated integrating sphere setup. Our results demonstrate the general suitability of these one-step loading procedures for efficient particle staining with neutral, zwitterionic, and charged fluorophores like oxazines, coumarines, squaraines, xanthenes, and cyanines emitting in the visible and near infrared. Dye polarity was identified as a suitable tool to estimate the loading efficiency of fluorophores into these polymer particles.
Micromachining experiments were performed with Ti:sapphire laser pulses (130 fs - 150 fs, 800 nm, approximately 10 Hz) in air. Employing the direct focusing technique, highly absorbing titanium nitride (TiN) and weakly absorbing polyimide (PI) and polymethylmethacrylate (PMMA) served as target materials. The lateral and vertical precision of the laser ablation and morphological features were characterized by scanning force (SFM), scanning electron (SEM) and optical microscopy. For TiN, incubation can be observed, i.e. the single-pulse surface damage threshold (0.26 J/cm2) is by a factor of two greater than the threshold for 100 pulses. Ablation rates below 10 nm per pulse can be achieved. The evolution of sub-wavelength ripples is presented in dependence on pulse number and laser fluence, respectively. The incubation behavior of the polymers can be described by an accumulation model as for TiN. Experiments on PI with varying focal lengths result in the same modification thresholds. Different polarization states of light (linear, circular) lead to a variation of the ablation rate and to various morphological patterns in the ablation craters (wavelength ripples, cones). Swelling of PMMA occurred at fluences below the ablation threshold.
This contribution investigates laser-induced damage of thin film and bulk polymer
samples, with the focus on physical processes occurring close to the damage threshold. In-situ
real-time reflectivity (RTR) measurements with picosecond (ps) and nanosecond (ns) temporal
resolution were performed on thin polymer films on a timescale up to a few microseconds (µs).
A model for polymer thin film damage is presented, indicating that irreversible chemical
modification processes take place already below the fluence threshold for macroscopic damage.
On dye-doped bulk polymer filters (as used for laser goggles), transmission studies using fs-and
ps-laser pulses reveal the optical saturation behavior of the material and its relation to the
threshold of permanent damage. Implications of the sub-threshold processes for laser safety
applications will be discussed for thin film and bulk polymer damage.
The thickness measurement of transparent layers with optical techniques is very problematic. The observed deviations can easily reach 100% of the layer thickness to be measured. In order to analyse these deviations, tactile reference measurements have been developed. The proposed method is based on contact mode measurements with low contact pressure. With stylus instruments, this can be realized either by using the recommended tip radius of 2 µm and very small probing forces in the micronewton range (and low scanning speeds of 50 µm s-1) or by using the recommended probing force of 750 µN, but a large probing tip radius. Three metal layers on silicon or silicon dioxide and two polymer resist materials on a thin chromium adhesive layer on silicon are used as artefacts. The comparison of the optical measurements with the tactile reference values disclosed deviations of the optical measurements of up to 195% of the layer thickness. Layer thicknesses were between 200 nm and 4 µm. This paper analyses the deviations of two white light interference microscopes, one phase shift interference microscope, one confocal microscope, one autofocus sensor, a chromatic sensor, an interferometric film thickness sensor and one spectroscopic ellipsometer. Simple and well-known expressions for the description of the observed deviations are presented and discussed. The order of magnitude of the observed deviations can be described well by these correction formulas but further investigations are necessary in order to better understand the systematic deviations of optical surface measuring instruments on non-cooperating surfaces.