Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (20)
- Zeitschriftenartikel (8)
- Beitrag zu einem Sammelband (4)
- Buchkapitel (2)
- Beitrag zu einem Tagungsband (2)
- Posterpräsentation (1)
Schlagworte
- Messtechnische Rückführung (2)
- Permeable reactive barriers (2)
- Qualitätsmanagement (2)
- Radioindicator (2)
- Recycling (2)
- Uranium (2)
- Akkreditierung (1)
- Analysis (1)
- Audits (1)
- Carrier gas hot extraction (1)
Eingeladener Vortrag
- nein (20)
Analytical quality assurance
(2007)
This study was undertaken to investigate the long-term performance of hydroxyapatite (HAP) as reactive material for the removal of uranium in passive groundwater remediation systems. 237U used as a radioindicator enabled tracking the movement of the contamination front through a test column without taking samples or dismantling the apparatus. The stoichiometric ratio between uranium and HAP was found to be 1:(487±19). Uranium removal by HAP is of pseudo first-order kinetics and the rate constant was measured to be (1.1±0.1)×10-3 s-1. HAP can sorb more than 2900 mg/kg uranium. Possible reaction pathways of uranium and HAP are discussed. The data obtained enable the calculation of ideal lifetime for permeable reactive barriers (PRB) using HAP for uranium removal neglecting hydrological factors that may impair the function of PRBs.
This study was undertaken to investigate the long-term performance of elemental iron as reactive material for the removal of uranium in passive groundwater remediation systems. By using 237U as a radioindicator it was possible to track the movement of the contamination front through a test column without taking samples or dismantling the apparatus. The stoichiometric ratio between uranium and iron was found to be 1:(1390±62). The reaction between iron and uranium is of pseudo first-order kinetics and the rate constant was measured to be (1.1±0.09)×10-3 s-1. These data enable the calculation of ideal lifetime for permeable reactive barriers (PRB) using iron for uranium removal neglecting hydrological factors that may impair the function of PRBs.
Zusammenfassung
The working principle of nuclear analytical methods (NAMs) is not influenced by the chemical bond. Consequently, they are independent counterparts to the well-known chemical procedures. NAMs obey fundamental laws or can be described and understood thoroughly. This qualifies them as candidates for reference methods. Although following similar nuclear reaction schemes, they comprise bulk analyzing capability (neutron and photon activation analysis) as well as detection power in surface near regions of solids (ion beam techniques). Prominent features of NAMs are sensitivity, selectivity, multielement determination and linearity of the calibration function covering a concentration range of several orders of magnitude. Moreover, ion beam techniques allow depth profiling with nm-resolution in several cases while the ion microprobe additionally offers a lateral resolution in the wm-scale. As NAMs require expensive apparatus (nuclear reactor, accelerator in radioactive control areas) their availability is restricted to a small number of suitably equipped institutes. However, they are able to solve complex analytical tasks, take part in key comparisons and play an essential role in the certification of reference materials.