Sift-proofness is a requirement for different types of dangerous goods packagings for solid substances according to the international Dangerous Goods Regulations. In these regulations, a siftproof packaging is defined as a packaging which is completely impermeable to dry contents. This means indirectly that absolutely no mass transport of solid substances is allowed. Moreover, this requirement applies both to the original filling substance and to fine solid material generated during transport. Further specifications, test conditions or tolerable limit values are not given. This is in contrast to physical principles and the usual practice in other fields of technology in which sift-proofness is relevant.
This article shows the necessary steps for how the requirements for sift-proofness of dangerous goods packagings can be defined more precisely. Physical basics of the term “sift-proofness” are explained. A qualitative as well as a quantitative approach are possible. In any case, it is essential to carry out appropriate vibration tests to assess the sift-proofness. There is a need for systematical investigations of the sift-proofness of dangerous goods packagings.
Discussions in science, politics and public media about microplastic in the Environment and its unclear effects for animals and humans are common these days.
Although microplastic findings in water, soil and even air are well known, no general estimations about the quality or quantity of microplastic particles in environment exit. Research is necessary to develop reliable and traceable, harmonized protocols for sampling, sample preparation and fast, but accurate analysis for qualitative and quantitative measurement of microplastic in various environmental matrices. For development of such reliable and traceable methods, the use of microplastic reference materials is necessary to assess various concepts. These microplastic reference particles should be an appropriate reflection of the microplastic particles found in environment.
Due to the high use in industrial products six polymers seem to be relevant in environment as microplastic particles: polyethylene (PE), polypropylene (PP), polystyrene (PS), polyethylene terephthalate (PET), polyamide (PA) and polyvinylchloride (PVC). The raw source of These thermoplastic materials are pellets or granulate with dimensions of 1 to 5 mm in diameter. Most common they own a regular cylindrical shape or are prolate sphericals. These can be bought cost-efficient by various polymer producers. But discussions in microplastic research topic lead to particle sizes down to 1 μm. Furthermore, various unregular shapes and geometries of the particles have to be considered as well as an oxidized surface. In the present work we engage the acquisition and production of
realistic reference material. Different aspects should demonstrate the complex and difficult task of generating approriate, cost-efficient and well-defined reference materials. The particle size distribution by using
different particle sizing methods as well as individual particle shapes are documented. Different material properties were addressed. PE, PS and PA were chosen as typical and relevant microplastic with opposite individual material characteristics in density and glass Transition temperature. The easiest possibility for acquisition of small microplastic particles is the purchase of polymer emulsion particles (20 to 150 μm).
An alternative possibility to produce small microplastic particles is milling under liquid nitrogen conditions in cryo mills. Particles purchased or self-made differ strongly in shape and size depending on production method.
SETAC
Supramolecular chemistry, fluorescence detection, hybrid (nano)materials and device miniaturization are in themselves highly interesting areas of research, yet especially their combination paves the way to (bio)chemical analysis systems that show outstanding performance. The lecture gives an overview of the toolbox of single components developed in BAM’s Chemical and Optical Sensing Division over the years, and how their combination can result in powerful sensors, quick tests and assays. While at the core of a development is the analytical problem, that is, the determination of a certain analyte in a sample of interest with the required sensitivity and selectivity by a specific end user in a given setting, signaling mechanisms, recognition elements, signal transduction modes, materials functionalization, device design and system integration are adequately chosen, tailored and adapted. Examples including molecularly imprinted polymers, hybrid mesoporous nanomaterials, gated indicator release systems, microfluidic devices, test strips and smartphone-based analysis will be presented.
The leaks of dangerous goods from actually intact bags detected in the years 2018 to 2020 tend to be at an almost constant high level. These releases of powdery or granular dangerous goods represent violations of the sift-proofness required in the dangerous goods regulations. This article first analyzes the causes. The components of the bags that are affected by leaks are micro-perforations, joins and closures, in particular internal sleeve valves. A distinction must be made between bags closed in conformity with or contrary to the manufacturer's instructions. The particle release is determined by a number of influencing factors of the filling substance, the packaging and other boundary conditions. Therefore, a comprehensive test concept is developed in this work, which takes all these factors into account. The application of this test concept facilitates the planning of the test setup and the experiments. On this basis, the complex mechanisms involved in the release of solid substances can be systematically investigated in the test laboratory. To prevent releases of powdery or granular substances from intact bags, it is necessary that the user has access to the closing instructions and the relevant properties of the test substance used for the design type approval. Further experimental investigations are needed to assess whether filling substances change their properties during transport and whether this enables them to escape.
Quantitative chemical analysis of airborne particulate matter (PM) is vital for the understanding of health effects in indoor and outdoor environments, as well as for enforcing air quality regulations. Typically, airborne particles are sampled over long time periods on filters, followed by lab-based analysis, e.g., with inductively coupled plasma mass spectrometry (ICP-MS). Within the EURAMET EMPIR AEROMET project, cascade impactor aerosol sampling was combined for the first time with on-site total reflection X-ray fluorescence (TXRF) spectroscopy to develop a tool for quantifying particle element compositions within short time intervals and even on-site. This makes variations of aerosol chemistry observable with time resolution of only a few hours and with good size resolution in the PM10 range. A proof of principles of this methodological approach and the comparison to standard methods within the scope of a field campaign will be presented. Secondly, aerosol sampling and TXRF analysis seems suitable for the quantification of elements in indoor aerosols as well and may provide an important enhancement of existing methods for the analysis of organic species in aerosols (such as sampling and TD-GC/MS). As an example, the TXRF analysis of particles emitted from laser printers under controlled conditions in an environmental test chamber will be presented.
Microbial contamination of fuels by fungi or bacteria poses risks such as corrosion and fuel system fouling, which can lead to critical problems in refineries and distribution systems and has a significant economic impact at every stage of the process. Many factors have been cited as being responsible for microbial growth, like the presence of water in the storage tanks. In fact, only 1 % water in a storage system is sufficient for the growth of microorganisms like bacteria or yeasts, as well as for the development of fungal biomass at the oil/water interface.
This work presents a rapid test for the accurate determination of genomic DNA from aqueous fuel extracts. The detection is based on the use of polystyrene-mesoporous silica core-shell particles onto which modified fluorescent molecular beacons are covalently grafted. These beacons contain in the hairpin loop a target sequence highly conserved in all bacteria, corresponding to a fragment of the 16S ribosomal RNA subunit. The designed single-stranded molecular beacon contained fluorescein as an internal indicator and a quencher in its proximity when not hybridized. Upon hybridization in presence of the target sequence, the indicator and the quencher are spatially separated, resulting in fluorescence enhancement. To perform the assay the developed particles were deposited on different glass fibre strips to obtain a portable and sensitive rapid test. The assays showed that the presence of genomic DNA extracts from bacteria down to 50–70 μg L–1 induced a fluorescence response. The optical read-out was adapted for on-site monitoring by fitting a 3D-printed case to a conventional smartphone, taking advantages of the sensitivity of the CMOS detector. Such embedded assembly enabled the detection of genomic DNA in aqueous extracts down to the mg L–1 range and represents an interesting step toward on-site monitoring of fuel contamination.