High-resolution mass spectrometry, either combined with gas or liquid chromatography (GC/LC-HR-MS), is currently the most powerful analytical option for broad nontargeted small molecule analysis. To transform HR-MS raw data from metabolomics or environmental studies into chemically meaningful data, several computational steps are needed, including peak detection, deconvolution of these peaks into compounds and putative identification of compounds using databases. Each of these steps can cause problems and still requires methodological advancements. Computational compound annotation as one of the steps, however, has proven particularly challenging, mainly due to the chemical diversity of organic analytes. In addition, different annotation approaches are needed for the different platforms used in HR-MS screening. We recently introduced InterpretMSSpectrum as an annotation workflow for GC-HR-MS using atmospheric pressure chemical ionization (APCI). InterpretMSSpectrum locates molecular ion, fragment and adduct peaks, calculates their most likely sum formula combination and graphically summarizes results as an annotated mass spectrum. As a complementary approach for LC-HR-MS, we presented findMAIN, which scores MS1 spectra based on explained intensity, mass accuracy and isotope charge agreement of adducts and related electrospray ionization (ESI) products to determine the neutral mass of unknown compounds. Both approaches were validated against large spectral libraries containing more than 600 compounds, for which correct annotation was achieved in over 80% of the cases. Based on the experiences from this validation, we here compare soft-ionization GC/LC-HR-MS regarding “annotatability” of unknown compounds from a computational perspective. As a main advantage for GC-HR-MS, the relatively uniform ionization behavior of commonly used trimethylsilyl (TMS) derivatives observed under APCI allowed differentiation of molecular ion peaks from in-source fragments based on relatively compact set of rules. By contrast, neutral mass inference in ESI required a more complex evaluation scheme, due to the higher diversity of ionization products observable in ESI. We demonstrate such differences by practical examples of both software packages applied to metabolomics studies and discuss the challenges connected to transferring the approaches to environmental screening.
Mass spectrometric Methods MC-ICP-MS and TIMS) are without doubt the working horse of stable isotope analysis. However, drawbacks of these methods include the high costs for instruments and their operation, experienced operators and elaborate chromatographic sample preparation which are time consuming.
Optical spectrometric methods are proposed as faster and low-cost alternative for the analysis of isotope ratios of selected elements by means of high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS) and laser ablation molecular isotopic spectrometry (LAMIS). First, stable isotope amount compositions of boron (B) and magnesium (Mg) were determined based on the absorption spectra of in-situ generated heteronuclear diatomic molecules (MH or MX) in graphite furnace HR-CS-MAS. The use of a modular simultaneous echelle spectrograph (MOSES) helps to find the maximal isotope shift in the diatomic molecular spectra produced in a graphite furnace by using isotopic spike solutions. Isotopes of boron (10B and 11B) were studied via their hydrides for the electronic transition X 1Σ+ → A 1Π. The spectrum of a given sample is a linear combination of the 10BH molecule and its isotopologue 11BH. Therefore, the isotopic composition of samples can be calculated by a partial least square regression (PLS). For this, a spectral library was built by using samples and spikes with known isotope composition. Boron isotope ratios measured by HR-CS-MAS are identical with those measured by mass spectrometric methods at the 0.15 ‰ level. Similar results were obtained for a multiple isotope system like Mg (24Mg, 25Mg, and 26Mg), where isotope shifts of their isotopologues can be resolved in the MgF molecule for the electronic transition X 2Σ → A 2 Πi. Finally, the application of molecular spectrometry via emission by LAMIS is compared and discussed.
The use of inorganic lanthanide-doped upconversion nanoparticles (UCNP) in bioimaging and cellular studies requires biocompatible particles. One possible cause of UCNP toxicity is the release of potentially harmful fluoride and lanthanide ions as revealed by dilution studies in aqueous environments, particularly under high dilution conditions. To address this issue, suitable surface coatings preventing such effects in combination with fast screening methods suited for online monitoring and in situ analyses are desired.
Here we present systematic studies of differently sized β-NaYF4:Yb,Er UCNP stabilized with different surface coatings and hydrophilic ligands varying in binding strength to the particle surface in various aqueous environments at different temperatures and UCNP concentrations. The concentration of the fluoride and lanthanide ions released upon particle dissolution was quantified electrochemically with a fluoride ion-sensitive electrode and inductively coupled plasma optical emission spectrometry (ICP-OES) and monitored fluorometrically, thereby exploiting the sensitivity of the upconversion luminescence to changes in size and surface chemistry. Moreover, changes in surface chemistry were determined with X-Ray photoelectron spectroscopy (XPS). Based upon our results, we could derive optimum screening parameters for UCNP stability studies and determine conditions and coating procedures and ligands for enhancing UCNP stability in aqueous environments.
The climate and energy crisis are extreme challenges. One possible solution could be hydrogen technology. Safety is a big concern. Steel used for pipelines and storage is under permanent stress from low temperatures and high pressures. The content of different alloyed metals determines the performance of the steel. Nitrogen microwave inductively coupled atmosphere pressure plasma mass spectrometry (N2-MICAP-MS) is a promising method for trace metal analysis in steel. Nitrogen is cheap and can be generated on site. It has fewer interferences than argon. Additionally, MICAP-MS is very matrix tolerant, proving the matrix-matched calibration expendable. Safety in technology and chemistry is the mission of BAM. Providing reference methods and materials can create trust in future technologies like hydrogen.
Isotope Ratio Analysis