Photothermal radiometry with an infrared camera allows the contactless temperature measurement of multiple surface pixels simultaneously. A short light pulse heats the sample. The heat propagates through the sample by diffusion and the corresponding temperature increase is measured at the samples surface by an infrared camera. The main drawback in radiometric imaging is the loss of the spatial resolution with increasing depth due to heat diffusion, which results in blurred images for deeper lying structures. We circumvent this information loss due to the diffusion process by using blind structured illumination, combined with a non-linear joint sparsity reconstruction algorithm.
The separation of two closely spaced defects in fields of Thermographic NDE is very challenging. The diffusive nature of thermal waves leads to a fundamental limitation in spatial resolution. Therefore, super resolution image reconstruction can be used. A new concerted ansatz based on spatially structured heating and joint sparsity of the signal ensemble allows for an improved reconstruction of closely spaced defects. This new technique has been studied using a 1D laser array with randomly chosen illumination pattern.
This paper presents the results after applying super resolution algorithms, such as the iterative joint sparsity (IJOSP) algorithm, to our processed measurement data. Different data processing techniques before applying the IJOSP algorithm as well as the influence of regularization parameters in the data processing techniques are discussed. Moreover, the degradation of super resolution reconstruction goodness by the choice of experimental parameters such as laser line width or number of measurements is shown.
The application of the super resolution results in a spatial resolution enhancement of approximately a factor of four which leads to a better separation of two closely spaced defects.
Thermographic nondestructive evaluation (NDE) is based on the interaction of thermal waves with inhomogeneities. These inhomogeneities are related to sample geometry or material composition. Although thermography is suitable for a wide range of inhomogeneities and materials, the fundamental limitation is the diffusive nature of thermal waves and the need to measure their effect radiometrically at the sample surface only. The propagation of the thermal waves from the heat source to the inhomogeneity and to the detection surface results in a degradation in the spatial resolution of the technique. A new concerted ansatz based on a spatially structured heating and a joint sparsity of the signal ensemble allows an improved reconstruction of inhomogeneities. As a first step to establish an improved thermographic NDE method, an experimental setup was built based on structured 1D illumination using a flash lamp behind a mechanical aperture. As a follow-up to this approach, we now use direct structured illumination using a 1D laser array. The individual emitter cells are driven by a pseudo-random binary pattern and are additionally shifted by fractions of the cell period. The repeated measurement of these different configurations enables to illuminate each spot of the sample surface in lateral direction. This allows for a reconstruction that makes use of joint sparsity.
The measured data set is processed using super resolution image reconstruction algorithms such as the iterative joint sparsity (IJOSP) algorithm. Using this reconstruction technique and 150 different illumination patterns results in a spatial resolution enhancement of approximately a factor of four compared to the resolution of 5.9 mm for homogenously illuminated thermographic reconstruction.
Further, new data processing techniques have been studied before applying the IJOSP algorithm that are more performant or less prone to errors regarding image reconstruction. The choice of regularization parameters in data processing as well as experimental parameters such as the illumination pattern as a variable heat flux density (i.e., the Neumann boundary condition for convolution with the constant Green's function) have a big influence on the reconstruction goodness. With analytical-numerical modelling and numerical FEM simulations, we studied the influence of the experimental parameters on the result of the non-linear IJOSP reconstruction. This has also been investigated experimentally e.g. using different laser line widths or more measurements per position. These studies are used to derive optimal conditions for a certain measurement image reconstruction technique.
The work to be presented focuses on our most recent studies to laser excited super resolution (SR) thermography. The goal of nondestructive testing with SR is to facilitate the separation of closely spaced defects. Photothermal SR can be realized by performing structured illumination measurements in com-bination with the use of deconvolution algorithms in post-processing. We explain that stepwise as well as continuous scanning techniques are applicable to generate structured illumination measurements. Finally, we discuss the effect of experimental parameters and image processing techniques to find the optimal SR technique which leads to the highest reconstruction quality within laser thermography.
Die thermografische ZfP basiert auf der Wechselwirkung von thermischen Wellen mit Inhomogenitäten. Die Ausbreitung von thermischen Wellen von der Wärmequelle zur Inhomogenität und zur Detektionsoberfläche entsprechend der thermischen Diffusionsgleichung führt dazu, dass zwei eng beieinander liegende Defekte fälschlicherweise als ein Defekt im gemessenen Thermogramm erkannt werden können. Um diese räumliche Auflösungsgrenze zu durchbrechen, also eine Super Resolution zu realisieren, kann die Kombination von räumlich strukturierter Erwärmung und numerischen Verfahren des Compressed Sensings verwendet werden.
Für unsere Arbeiten benutzen wir Hochleistungs-Laser im Kilowatt-Bereich um die Probe entweder hochaufgelöst entlang einer Linie (1D) abzurastern oder strukturiert zu erwärmen. Die Verbesserung des räumlichen Auflösungsvermögens zur Defekterkennung hängt dann im klassischen Sinne direkt von der Anzahl der Messungen ab. Mithilfe des Compressed Sensings und Vorkenntnissen über das System ist es jedoch möglich die Anzahl der Messungen zu reduzieren und trotzdem Super Resolution zu erzielen. Wie viele Messungen notwendig sind und wie groß der Auflösungsgewinn gegenüber der konventionellen thermografischen Prüfung mit flächiger Erwärmung ist, hängt von einer Reihe von Messparametern, der Messstrategie, Probeneigenschaften und den verwendeten Rekonstruktionsalgorithmen ab.
Unsere Studien befassen sich mit dem Einfluss der experimentellen Parameter, wie z.B. der Pulslänge der Laserbeleuchtung und der Größe des Laserspots. Weiterhin haben wir uns mit der Wahl der Parameter in der Rekonstruktion auseinandergesetzt, die einen Einfluss auf das im Compressed Sensing zugrundeliegende Minimierungsproblem haben. Für jeden getesteten Parametersatz wurde eine Rekonstruktionsqualität berechnet. Schließlich wurden die Defektrekonstruktionen basierend auf den Parameternsätzen verglichen, sodass eine Parameterwahl für hohe Rekonstruktionsqualitäten mit thermografischer Super Resolution
empfohlen werden kann.
Active thermography as a nondestructive testing modality suffers greatly from the limitations imposed by the diffusive nature of heat conduction in solids. As a rule of thumb, the detection and resolution of internal defects/inhomogeneities is limited to a defect depth to defect size ratio greater than or equal to one. Earlier, we demonstrated that this classical limit can be overcome for 1D and 2D defect geometries by using photothermal laser-scanning super resolution. In this work we report a new experimental approach using 2D spatially structured illumination patterns in conjunction with compressed sensing and computational imaging methods to significantly decrease the experimental complexity and make the method viable for investigating larger regions of interest.
Für die aktive Thermografie als zerstörungsfreie Prüfmethode galt lange Zeit die Faustformel, dass die Auflösung interner Defekte/Inhomogenitäten auf ein Verhältnis von Defekttiefe/Defektgröße ≤ 1 beschränkt ist. Die Ursache hierfür liegt in der diffusiven Natur der Wärmeleitung in Festkörpern. Sogenannte Super-Resolution-Ansätze erlauben seit Kurzem die Überwindung dieser physikalischen Grenze um ein Vielfaches. Damit ergibt sich die attraktive Möglichkeit die Thermografie von einem rein oberflächensensitiven Prüfverfahren hin zu einem Verfahren mit verbesserter Tiefenreichweite zu entwickeln. Wie weit diese Entwicklung getrieben werden kann, ist Gegenstand aktueller Forschung. Wir konnten bereits zeigen, dass diese klassische Einschränkung für ein- und zweidimensionale Defektgeometrien überwunden werden kann, indem das Prüfobjekt mit einzelnen Laserspots sequenziell strukturiert beleuchtet wird und damit anschließend aus den resultierenden Messdaten durch Anwendung photothermischer Super-ResolutionRekonstruktion eine Defektkarte berechnet werden kann, welche eine deutlich verbesserte Trennung einzelner naheliegender Defekte erlaubt. Dieses Verfahren profitiert dabei im Ergebnis stark von der Kombination von sequenzieller räumlich strukturierter Beleuchtung und modernen numerischen Optimierungsverfahren, was jedoch in Summe stark auf Kosten der experimentellen Komplexität geht. Dies führt im Gegensatz zur Anwendung von etablierten thermografischen Standardverfahren mit vollflächiger Beleuchtung zu langen Messzeiten, großen Datensätzen und langwieriger numerischer Auswertung. In dieser Arbeit berichten wir über die Anwendung vollflächig räumlichstrukturierter zweidimensionaler Beleuchtungsmuster, welche es durch den Einsatz modernster Laserprojektortechnik in Verbindung mit einem Hochleistungslaser überhaupt erst erlaubt, eine effiziente Umsetzung von photothermischer Super-ResolutionRekonstruktion auch für größere Prüfflächen zu erreichen.
Due to the diffusive nature of heat propagation in solids, the detection and resolution of internal defects with active thermography based non-destructive testing is commonly limited to a defect-depth-to-defect-size ratio greater than or equal to one. In the more recent past, we have already demonstrated that this limitation can be overcome by using a spatially modulated illumination source and photothermal super resolution-based reconstruction. Furthermore, by relying on compressed sensing and computational imaging methods we were able to significantly reduce the experimental complexity to make the method viable for investigating larger regions of interest. In this work we share our progress on improving the defect/inhomogeneity characterization using fully 2D spatially structured illumination patterns instead of scanning with a single laser spot. The experimental approach is based on the repeated blind pseudo-random illumination using modern projector technology and a high-power laser. In the subsequent post-processing, several measurements are then combined by taking advantage of the joint sparsity of the defects within the sample applying 2D-photothermal super resolution reconstruction. Here, enhanced nonlinear convex optimization techniques are utilized for solving the underlying ill-determined inverse problem for typical simple defect geometries. As a result, a higher resolution defect/inhomogeneity map can be obtained at a fraction of the measurement time previously needed.
Für die aktive Thermografie als zerstörungsfreie Prüfmethode galt lange Zeit die Faustformel, dass die Auflösung interner Defekte/Inhomogenitäten auf ein Verhältnis von Defekttiefe/Defektgröße ≤ 1 beschränkt ist. Die Ursache hierfür liegt in der diffusiven Natur der Wärmeleitung in Festkörpern. Sogenannte Super-Resolution-Ansätze erlauben seit Kurzem die Überwindung dieser physikalischen Grenze um ein Vielfaches. Damit ergibt sich die attraktive Möglichkeit die Thermografie von einem rein oberflächensensitiven Prüfverfahren hin zu einem Verfahren mit verbesserter Tiefenreichweite zu entwickeln. Wie weit diese Entwicklung getrieben werden kann, ist Gegenstand aktueller Forschung.
Wir konnten bereits zeigen, dass diese klassische Grenze für 1D- und 2D-Defektgeometrien mit Hilfe des Abscannens des Prüfkörpers mittels einzelner Laserspots und der anschließenden Anwendung von photothermischer Super-Resolution-Rekonstruktion überwunden werden kann. Bei dieser Methode wird eine Kombination aus sequenzieller räumlich strukturierter Beleuchtung und numerischen Optimierungsmethoden eingesetzt. Dies geschieht allerdings auf Kosten der experimentellen Komplexität, die zu einer langen Messdauer, großen Datensätzen und langwieriger numerischer Auswertung führt.
In dieser Arbeit berichten wir über einen neuen experimentellen Ansatz, bei dem räumlich strukturierte 2D-Beleuchtungsmuster in Verbindung mit Compressed-Sensing und Computational-Imaging-Methoden verwendet werden, um die experimentelle Komplexität deutlich zu verringern und die Methode für die Untersuchung größerer Prüfflächen nutzbar zu machen.
Der experimentelle Ansatz basiert dabei auf der wiederholten (blinden) photothermischen Anregung mit räumlich strukturierten 2D-Mustern unter Verwendung moderner Projektortechnik und eines Hochleistungslasers. In der anschließenden numerischen Rekonstruktion werden mehrere Messungen unter Ausnutzung der Joint-Sparsity der Defekte innerhalb des Prüfkörpers mittels nichtlinearer konvexer Optimierungsmethoden kombiniert. Als Ergebnis kann eine 2D-sparse Defekt-/Inhomogenitätskarte erstellt werden.
In this work, we report on our progress for investigating a new experimental approach for thermographic detection of internal defects by performing 2D photothermal super resolution reconstruction. We use modern high-power laser projector technology to repeatedly excite the sample surface photothermally with varying spatially structured 2D pixel patterns. In the subsequent (blind) numerical reconstruction, multiple measurements are combined by exploiting the joint-sparse nature of the defects within the specimen using nonlinear convex optimization methods. As a result, a 2D-sparse defect/inhomogeneity map can be obtained. Using such spatially structured heating combined with compressed sensing and computational imaging methods allows to significantly reduce the experimental complexity and to study larger test surfaces as compared to the one-dimensional approach reported earlier.