Filtern
Dokumenttyp
- Vortrag (6) (entfernen)
Sprache
- Englisch (6)
Referierte Publikation
- nein (6)
Schlagworte
- Flow cytometry (6) (entfernen)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (6)
FLiMFlow – Recent achievements in flow cytometry with lifetime detection and lifetime-encoded beads
(2016)
Flow cytometry is a widespread technique in biological research and clinical applications. Two different directions are currently of importance in development of new methods in this field. Whereas analyses in research become increasingly complex and require a growing number of simultaneously detectable codes and fluorescent labels, also low-cost methods and portable devices are needed in routine application.
Lifetime encoding could present an alternative to common spectral multiplexing. On the one hand, it addresses the need for additional codes by combining spectral and lifetime multiplexing. On the other hand, using only lifetime encoding could help to reduce instrument costs by keeping the number of excitation sources and detectors low.
Here, we report on our recent progress in employing dye-stained lifetime-encoded polymer microparticles as a model system for lifetime encoding in flow cytometry. The discrimination of two lifetime codes was achieved with two bead sets. Moreover, the simultaneous detection of a spectrally different ligand fluorescence signal could be demonstrated.
For the application of time-resolved detection in the framework of flow cytometry, suitable luminescence lifetime code carriers are required. Here we report on our achievements concerning strategies to increase the accessible range of lifetime values and to realize continuously tunable lifetimes.
To that end, we investigated polymer (PMMA) microbeads stained with mixtures of dyes exhibiting different fluorescence decay kinetics. At the expense of spectrally varying decay kinetics, it is possible to modify the lifetime by changing the dye concentration ratio.
Moreover, semiconductor quantum dots incorporated into polymer beads were studied as alternative luminophores outperforming organic dyes with respect to long luminescence lifetimes, flexible choice of excitation wavelength and narrow spectral emission width.
Our experiments demonstrate that lifetime adaption with dye mixing is basically feasible and semiconductor quantum dots represent promising candidates for long-lifetime codes.
Multiparametric analyses involving optical techniques like flow cytometry are at the core of studying complex systems in biological research and diagnostic applications. However, for fluorescence-based techniques, the number of reporters distinguishable in spectral multiplexing is limited by spectral overlap and requires a multitude of excitation light sources and detection Systems. Intensity encoding often used for bead assays suffers from problems regarding dye concentration control and excitation light intensity fluctuations. An alternative is luminescence lifetime encoding, particularly to minimize instrument costs.
Here, we report on dye-stained polymer microparticles for lifetime encoding in flow cytometry with different organic dyes. This ranges from studies of the impact of parameters like dye loading concentration and particle diameter on fluorescence decay behavior to the demonstration of lifetime code reading and simultaneous ligand fluorescence signal detection with single-wavelength excitation in a flow.
Dye-stained lifetime-encoded polymer microbeads for application in time-resolved flow cytometry
(2017)
Flow cytometry is a standard analytical tool for biological research and in medical applications. There are different requirements triggering recent device and method development depending on the desired field of application. One trend is governed by the need for an increasing number of simultaneously detectable codes, i.e., fluorescent labels. The other one focuses on cost-effective methods and development of miniaturized, portable devices.
Fluorophore encoding is usually based on spectral encoding. However, this approach is hampered by, e.g., spectral crosstalk. Additionally, the sensitivity of fluorescence intensity measurements to fluctuations in excitation light intensity and dye concentration limits the achievable number of detection channels. Moreover, spectral multiplexing typically requires several costly excitation light sources. Lifetime multiplexing and the discrimination between different encoding fluorophores and carrier beads based on their fluorescence decay kinetics could present an innovative alternative. Encoded beads, i.e., beads with lifetime codes corresponding to the surface chemistry, have been employed to evaluate the feasibility of this approach with a custom designed flow cytometer equipped with a pulsed light source and a fast detector for time-resolved measurements in a flow.
In a first step, we used steady state and time-resolved photoluminescence measurements for the spectroscopic characterization of micrometer-sized dye-stained PMMA beads. Subsequently, the potential use of these microbeads for flow cytometry applications was analyzed with a prototype flow cytometer with lifetime detection.
With our proof-of-concept studies, we could demonstrate that lifetime discrimination and simultaneous readout of a ligand fluorescence signal for analyte quantification is feasible with a set of dye-stained polymer microbeads at single wavelength excitation. These studies are expected to pave the road for new applications of fluorescence lifetime multiplexing in time-domain flow cytometry and bead-based assays in general.
Bioanalytical, diagnostic, and security applications require the fast and sensitive determination of a steadily increasing number of analytes or events in parallel in a broad variety of detection formats.[1,2] Ideal candidates for spectral encoding and multiplexing schemes are luminescent nanocrystals like semiconductor quantum dots (QDs), particularly Cd-containing II/VI QDs with their narrow and symmetric emission bands. With the availability of relatively simple and inexpensive instrumentation for time-resolved fluorescence measurements, similar strategies utilizing the compound-specific parameter fluorescence lifetime or fluorescence decay kinetics become increasingly attractive.[3-5] The potential of different types of QDs like II/VI, III/V and Cd-free ternary QDs such as AgInS (AIS) QDs for lifetime-based encoding and multiplexing has been, however, barely utilized, although the lifetimes of these nanocrystals cover a time windows which is barely accessible with other fluorophores. Here we present a brief insight into the photophysics of AIS QDs and show the potential of dye- and QD-encoded beads for lifetime-based encoding and detection schemes in conjunction with flow cytometry and fluorescence lifetime imaging microscopy
Spectral encoding of cells or particles and the discrimination of multiple spectral codes are a critical process in flow cytometry (FCM). Typical issues in spectral encoding are, e.g., the spectral overlap of codes, or the increasing complexity of instruments . The exploitation of the photoluminescence lifetime (LT) as an encoding parameter could be used to circumvent both of these issues, as it adds another dimension to the parameter space, or, when used as a stand-alone parameter, requiring only one excitation light source and one detector. While LT encoding was considered already decades ago it is still not implemented as a routine technique in FCM yet, mainly due to the challenge of very few photons being available within the limited transition time of a cell or particle through the laser spot.
Recently, we demonstrated LT-FCM based on luminophores with ns LTs in a compact and low-cost flow cytometer. Measurements on polymer microbeads containing luminophores with distinctly different excited state LTs enabled the complete discrimination of three LT codes and five codes in total could be identified.
Now, we have extended our approach towards considerably longer LTs by custom-made polymer microbeads loaded with different ratios of InP/ZnS and AgInS2 quantum dots. The use of these materials significantly expands the usable time range for LT encoding to up to several hundred ns. Our studies demonstrate the possibility to further increase the number of viable LT codes for multiplexing in LT-FCM without the need for extensive hardware modifications.