Air-coupled ultrasound has been applied increasingly as a non-destructive testing method for lightweight construction in recent years. It is particularly appropriate for composite materials being used in automotive and aviation industry. Air-coupled ultrasound transducers mostly consist of piezoelectric materials and matching layers. However, their fabrication is challenging and their signal-to-noise ratio often not sufficient for many testing requirements. To enhance the efficiency, air-coupled ultrasound transducers made of cellular polypropylene have been developed. Because of its small density and sound velocity, this piezoelectric ferroelectret matches the small acoustic impedance of air much better than matching layers applied in conventional transducers. In our contribution, we present two different methods of spherical focusing of ferroelectret transducers for the further enhancement of their performance in NDT applications. Measurements on carbon-fiber-reinforced polymer (CFRP) samples and on metal adhesive joints performed with commercially available focused air-coupled ultrasound transducers are compared to measurements executed with self-developed focused ferroelectret transducers.
Reliability analysis of the ultrasonic inspection system for the inspection of hollow railway axles
(2016)
Axles are safety critical train components that are subjected to significant cyclic loading during operation. If the crack is initiated in the axle, cyclic loading will lead to crack propagation. To maintain structural integrity, axles must be periodically inspected for fatigue cracks in the material. Deutsche Bahn uses mechanized ultrasonic inspection system to inspect hollow railway axles. The inspections are performed from the bore surface, using several conventional transducers with different incident angles, inspecting the axle along the entire length. As with the every safety critical system, the reliability of these inspections must be determined with regard to their flaw detection capabilities. Traditionally this is done according to the relevant standards for railway vehicles. To investigate the capability of the NDT system more thoroughly, we want to evaluate the capability of the inspection system to detect flaws by means of probability of detection (POD) curves. It will be shown that other parameters, beside the size of the crack, for example crack position in the axle, influence the detection of the crack. The influence of these parameters was evaluated using ultrasonic simulation. The evaluation served as an input for the manufacturing of the flaws in the real scale axle. Once these axles are inspected and the data evaluated, using data from both measurement and simulation, we will express the POD of the crack as function of influencing parameters using the multiparameter POD model.
The canister for the permanent storage of spent nuclear fuel used by SKB in Sweden consists of a cast iron insert surrounded by a five centimetre thick shell of copper. It is a safety critical component and in order to secure long-term structural integrity non-destructive methods are used to inspect 100% of the volume of each canister, before it is disposed of in the repository. One of the critical components that requires inspection is a sealing weld, joining the copper tube and the lid. The friction stir weld is inspected using an ultrasonic phased array system. The area of the weld is inspected with several inspection channels with different angles and varying coverage. To make sure that no defects that might occur in the weld are overseen, the reliability of the inspection must be quantified. The reliability of NDT is usually quantified with the probability of detection curves. The influence of the parameters that might influence the POD of the flaws in the weld is investigated analysing the experimental results, as well as with a help of a numerical simulation of the inspection.
Highly sensitive air-coupled ultrasonic sensors are essential for various applications such as testing of composite materials. One of the major challenges for the development of air-coupled ultrasonic sensors is the impedance matching to air. With a lower acoustic impedance than the usual piezoelectric materials, charged cellular polypropylene film (cPP) offers better matching to air with a similar piezoelectric coefficient. The piezoelectric behaviour demonstrated by cPP comes from polarized air cells that create a permanent internal voltage. The sensitivity of the sensor varies with the application of an additional DC bias voltage. Thus, this work presents a cPP ultrasonic sensor with an improvement of up to 15 ± 1 dB on the signal-to-noise ratio.
Nowadays, civil engineers have applied prestressing technique to long span bridges to enhance the structural strength and to improve the structural performance in their life time.
However, it‘s not easy to avoid prestress loss during the construction or in service time. This problem will influence the function of the structures and worse make our life in danger.
Therefore, it‘s important to focus on the topic „bridge monitoring“ to make sure the structural property is "health". This presentation introduces the work which fulfills the research goal - birdge monitoring. A large-scale prestressed concrete bridge model was considered in this work. We obteined various damaged condition due to the different prestressed levels which we can change every time in the experiment.
The experimental measurement in two scales were demonstrated by ultrasonics and natural vibration of the bridge.
In addition to already established structural monitoring methods such as deformation, inclination or strain gauges or acoustic emission sensors, sonic or ultrasonic monitoring might provide valuable information about the condition or alteration of a structure. Sensors such as geophones, recording ambient noise in the sonic and subsonic frequency range can provide information beyond modal analysis by using interferometric methods. Wave velocities determined by this method are related to the elastic properties and stiffness of material and structure and can be converted into damage indicators. Embedded active ultrasonic transducer networks can provide more detailed insight about deterioration or damages again, using interferometric technologies. This approach is extremely sensible, detecting relative change in velocity on down to 10-5. These methods, including benefits and remaining challenges, are demonstrated using data from a test structure at BAM’s test site demonstrating the case of prestress loss, and data from an actual bridge still under traffic.
Existing concrete structures were usually designed for lifetimes of several decades. The current and urgently required efforts to increase sustainability and protect the environment will likely result in extended service lives up to 100 years. To achieve such objectives, it is required to assess structures over their entire lifecycles. Non-destructive testing (NDT) methods can reliably support the assessment of existing structures during the construction, operational, and decommissioning phases. One of the most important and safety-relevant components of a prestressed concrete structure are the tendons. NDT methods such as the ultrasonic echo method are suitable for both the detection and the localization of the tendons, i.e., the measurement of their geometrical position inside the component. The uniqueness of structures, concrete heterogeneity, and varying amounts of secondary components such as the reinforcement represent obstacles in the application of these methods in practice. The aim of this contribution is to demonstrate a practicable procedure, that can be used in the field to determine the parameters required for the measuring data analysis without extensive knowledge about the investigated components. For this purpose, a polyamide reference specimen is used to show which steps are required to obtain reliable imaging information on the position of tendons from the measurement data. The procedure is then demonstrated on a concrete test specimen that covers various relevant and practice-oriented test scenarios, such as varying tendon depths and component thicknesses.
This study aims to develop a real-time monitoring method for the structural performance by ultrasonic testing in combination with six-component (6-C) translation and rotation measurements. So far, the recordings of the velocity and acceleration response in the translation direction have been used to obtain the eigenfrequencies of structures. Recently, measurement of rotation has been used to fully characterize the dynamic behavior of structures. In this research, 6-C sensors consisting of a three-component rotational seismometer and a three-component broadband seismometer are evaluated for their suitability for bridge monitoring. Since changes in environmental conditions such as temperature during vibration recordings affect the structural evaluation results, cross-correlation function is applied here to the 6-C ambient vibration signals to reconstruct the wave propagation on the one hand, and coda wave interferometry (CWI) is applied to obtain the internal velocity variation from waveforms on the other hand. In field tests on a large-scale prestressed concrete bridge model, it was verified whether the prestress loss can also be determined in presence of temperature effects. For this purpose, measurements were performed in two scales, ultrasonic and output-only vibration measurements. The change in structural properties due to the prestress loss should be detected by the pulse velocity change. The results demonstrate both the performance and advantages of ultrasonic techniques and the capabilities of 6-C sensors. Thus, the application of CWI to wave signals can contribute comprehensively to bridge monitoring.
Ultrasonic coda wave interferometry can detect small changes in scattering materials like concrete. We embedded ultrasonic transducers in the Gänstorbrücke Ulm, a monitored road bridge in Germany, to test the methodology. Since fall 2020, we've been monitoring parts of the bridge and comparing the results to commercial monitoring systems. We calculate signal and volumetric velocity changes using coda waves, and long-term measurements show that the influence of temperature on strains and ultrasound velocity changes can be monitored. Velocity change maps indicate that different parts of the bridge react differently to environmental temperature changes, revealing local material property differences. A load experiment with trucks allows calibration to improve detectability of possibly damaging events. Our work focuses on measurement reliability, potential use of and distinction from temperature effects, combination with complementary sensing systems, and converting measured values to information for damage and life cycle assessment.