Filtern
Dokumenttyp
- Vortrag (6) (entfernen)
Referierte Publikation
- nein (6) (entfernen)
Schlagworte
- Tanks (6) (entfernen)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (6)
Tanks with capacity larger than 700 m3, could be exposed to a resonance excitation when subjected to earthquake motions, regardless of the fill level. Further studies to assess the dynamic forces linked to such resonance and close-to-resonance situations, in a context of a standard overloading situation due to sloshing forces.
Formale Pflichterfüllung
(2019)
ERFA BAM - BAG
(2019)
Tanks sind für normale Beförderungsbedingungen gebaut und zugelassen! Tankkörper müssen nach Normen (siehe 6.8.2.6 RID/ADR) oder nach einem von der zuständigen Behörde anerkannten technischen Regelwerk entworfen und gebaut werden Schweißverbindungen müssen nach Regeln der Technik ausgeführt werden. Unterdruck im Tank ist zu berücksichtigen (Berechnung, Vakuumventil). Beständigkeit – Gefahrgut darf mit Tankwerkstoff nicht gefährlich reagieren oder die Werkstoffe merklich schwächen!
To reduce the global emission of CO2, liquified natural gas (LNG) is increasingly used as fuel. As the pipeline network is not developed all around the globe, LNG needs to be transported via ship or truck. Double-walled tanks made of steel with a vacuum insulation are currently used to keep LNG at cryogenic temperatures (-162 °C; 111 K). The double-walled construction makes the tanks heavy and expensive. The vacuum insulation between the two walled structure ensures that the LNG stays liquid over the transportation time (boiling point of LNG: -162 ◦C). This causes a high temperature difference between the transported good and the ambient air. Furthermore, there are some restrictions in carrying out in-service inspection using a double-wall design. Therefore, alternative tank designs, such as single wall glass fiber reinforced plastics (GFRP), are of growing interest.
The material properties of GFRP and tank insulation at cryogenic temperatures are investigated. Liquified nitrogen (-196 °C; 77 K) is used for all experiments at cryogenic temperatures for safety reasons. Thermal conductivity of different layers are investigated and compared. Mechanical properties are analyzed by performing 3-point bending tests on cooled specimen. When cooled, the specimens fail at a higher force, but all layers of the laminate fail at once. Further investigations into the characterization of material properties, such as CT scans are currently in preparation.
Evaluation is done by FEM and in approximation via analytical solutions.