An approach to achieve “zero leakage” is discussed with respect to the experience in Germany, where strict regulations for landfill lining and capping systems have been developed and issued because of large environmental problems related to landfills that accumulated in the 1970’s and 1980’s. These regulations for landfills and geosynthetics which are used in landfill liner and capping systems are shortly described. The main certification requirements for the products as well as conclusions for their use are presented. Using a thick, high quality HDPE geomembrane (GMB), which is installed free of residual waves and wrinkles in intimate contact with a compacted clay liner (CCL) or geosynthetic clay liner (GCL) of very low permeability, by a qualified, experienced, well equipped and properly third‐party controlled installer and which are protected by heavy protection layers designed with respect to long‐term performance of the GMB, may result in a liner or capping system of practically no leakage. This is demonstrated by analyzing results of measurements obtained from permanently installed leak detection systems in combination with HDPE GMBs.
Feasibility study: Continuous monitoring of pipes using distributed acoustic and fibre optic sensors
(2018)
The feasibility study „AGIFAMOR. Ageing infrastructures – distributed acoustic monitoring of pipes” is an interdisciplinary research project at BAM internally financed from 2015 to 2018. Therefore, the quite young fibre optic sensing technology of distributed acoustic sensing (DAS) was investigated to possibly be extended towards a global condition monitoring system for pipelines operating in real time.
DAS is a highly dynamic fibre optic sensing technology based on the method of coherent optical time domain reflectometry (C-OTDR). DAS allows capturing strain changes in the range of kHz. For the experimental work, the most suitable application yielding an optimum sensitivity was proven by wrapping a standard single-mode silica fibre around the pipe.
The DAS sensitivity was investigated regarding the detection of 1) incidents that initiate propagation of acoustic waves in the pipe wall, 2) changes inside the pipeline causing altered flow and 3) damage development in the pipe wall. Therefore, several testing setups in laboratory as well as in real scale were realized. For comparison purposes, experiments were accompanied by acoustic emission analyses and by measurements with accelerometers.
DAS was found to be very sensitive to gas ignition and its propagation across the pipe. Furthermore, the ability of DAS to detect and localize acoustic signals associated with pipeline leakage was demonstrated. The detection of crack formation and propagation within the pipe wall by means of DAS was studied during bending tests on several pipe segments, but was not proven so far with certainty. As expected, these studies turned out as the most difficult challenge due to the random occurrence and transient nature of microscopic damage phenomena.