Reliable analysis of chemical indicators in water, sediment and soil samples for the purpose of environmental pollution assessment poses one of the greatest analytical challenges, having in mind the complexity of sample matrix and low concentrations of pollutants. Organics (pesticides, PAHs, PCBs, etc.) and heavy metals (Hg, Cd, Ni, Pb and As) represent target parameters. Laboratories performing sampling and tests in this field regulated by respective EU directives [1], need strong support in terms of providing them with appropriate matrix CRMs enabling the process of quality control. NMIs and DIs with proven metrological capabilities for the production and certification of such materials are necessary for the provision of quality data. This project is aiming to develop capacity to produce CRMs for environmental analysis by transferring the theoretical and practical know-how between the partners and combining their skills to focus on environmental CRM production in accordance with ISO Guide 34 [2]. Production process includes good manufacturing practices for processing materials, method development and validation for homogeneity, stability and characterisation tests, characterisation of selected analytes together with additional information about matrix constituents, the calculation of individual uncertainties (between units inhomogeneity, long term stability, characterisation) and combination of uncertainties to determine overall uncertainty of the matrix reference materials. Inter laboratory comparison registered as EURAMET project is set as the ultimate project outcome, confirming the partners’ capabilities in applying newly acquired skills.
This paper investigates GMAW with respect to energy consumption and its associated environmental impacts. Different material transfer modes and power levels for Single Wire GMAW (SGMAW) and Tandem GMAW (TG-MAW) are evaluated by means of the indicator Electrical Deposition Efficiency. Furthermore, the wall-plug efficiency of the equipment is measured in order to describe the total energy consumption from the grid. The results show that energy efficiency is highly affected by the respective process and can be significantly enhanced by a TGMAW process. The wall-plug efficiency of the equipment shows no significant dependency on the power range or the material transfer mode. Moreover, the method of Life Cycle Assessment (LCA) is adopted in order to investigate the influences of energy efficient welding on the environmental impacts. In the comparative LCA study, the demand of electrical energy is reduced up to 24%. In consequence, the indicator values for GlobalWarming Potential (100), Acidification Potential, Eutrophication Potential and Photochemical Ozone Creation Potential that are applied to express the environmental impacts are reduced up to 11%.
Potentials for sustainable cement and concrete technologies - Comparison between Africa and Europe
(2017)
Cement and concrete technologies in Africa provide vast potentials for sustainable future technologies as well as enormous challenges. The main focus of the symposium is to address existing challenges, possible solutions, and future potentials with all participants. This symposium also aims at offering a platform for networking with relevant players in science and industry.
Weathering reference materials are used to characterize the harshness of an exposure, aiming on either reproducibility of a specific exposure or on the comparability between various kinds of weathering exposure.
The materials that are used as weathering reference materials differ in their sensitivities (as well as in interactions and interferences of the latter), conditioned by the different processes which lead to the respective property change. It is also essential to take into account the necessary measurement equipment for the respective property change, in order to allow timely intervention.
What are the key issues on choosing a weathering reference material?
What can be learned from the weathering reference materials, investigated so far?
Possibilities and limitations are discussed on the basis of existing weathering reference materials. Conclusions are drawn, for establishing new weathering reference materials.
Two nanosensors for simultaneous optical measurements of temperature (“T”), oxygen (“O”), and pH (“P”) have been designed. These “TOP” nanosensors are based on 100 nm-sized silica-coated polystyrene nanoparticles (PS-NPs) doped with the near infrared emissive oxygen- and temperature-sensitive chromium(III) complex ([Cr(ddpd)2][BPh4]3 CrBPh4)[1][2] and an inert reference fluorescence dye (Nile Red NR or 5,10,15,20-tetrakis-(pentafluorophenyl) porphyrin TFPP) and are covalently labeled with the pH-sensitive fluorophore fluorescein isothiocyanate (FITC). These emitters can be excited at the same wavelength and reveal distinguishable emission spectra suitable for ratiometric intensity-based and time-resolved studies in the visible and near infrared spectral region. The core-shell nanostructure of these sensors reveals high colloidal stability in various aqueous media. Studies in PBS buffer solutions and in a model body liquid demonstrate the applicability of the TOP nanosensors for optically detecting the three bioanalytically and biologically relevant analytes temperature, oxygen and pH simultaneously at the same position.
In the present paper the development of a semi-automated device for long-term monitoring of gaseous ammonia is described. A sensor material was produced that changes its optical properties in the pres-ence of low concentrations of ammonia in air. The implementation into an electronic device enables precise, simple, economic and fast monitoring of low concentrations of harmful gases, like ammonia, and hence can help to improve the climate monitoring in livestock housing, barns or stables.
Bisphenol A (BPA) is widely used in many Polymers. Many outdoor applications are made from BPA-based materials which are exposed to a variety of environmental impacts, like temperature, solar radiation, rain, and others. This could lead to damaging and aging of the material which might cause leaching or migration of pollutants into the environment. To understand the fate and behavior different transformation products of selected Bisphenols will be generated and analyzed.