Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (67) (entfernen)
Schlagworte
- LIBS (67) (entfernen)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (17)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (16)
- 1 Analytische Chemie; Referenzmaterialien (15)
- 1.9 Chemische und optische Sensorik (9)
- 9 Komponentensicherheit (6)
- 1.3 Instrumentelle Analytik (5)
- 9.4 Integrität von Schweißverbindungen (5)
- 7 Bauwerkssicherheit (3)
- 8.0 Abteilungsleitung und andere (3)
- 7.6 Korrosion und Korrosionsschutz (2)
Laser-induced breakdown spectroscopy has been employed for the investigation of the sulfur and chlorine content of building materials. Both, chloride and sulfate ions are major damaging species affecting the stability and lifetime of a structure. Chlorine and sulfur are mostly detected in the VUV and the NIR. In case of building materials the main elements like calcium or iron have many strong spectral lines over the whole spectral range, so that trace elements can only be detected in spectral windows unaffected from these lines. With regard to a preferably simply, robust against dust and vibrations and portable setup only the NIR spectral features are used for civil engineering applications.
Most detectors, mainly CCD cameras have rapidly decreasing quantum efficiency in the NIR. Also the quantum efficiency of the photocathode of CCD-Detectors with image intensifier is decreasing in the NIR. Different CCD-detectors were tested with respect to high quantum efficiency and high dynamic range, which is necessary for simultaneous detection of weak spectral lines from trace elements and intense spectral lines from main elements.
The measurements are made on reference samples consisting of cement, hydrated cement, cement mortar and concrete with well-defined amounts of the trace elements. Experimental conditions are chosen for an optimum intensity of the trace element spectral lines. The detector systems are compared by limit of detections and the signal to noise ratio.
Gated detection with intensified detectors, e.g., ICCDs, is today the accepted approach for detection of plasma emission in laser-induced breakdown spectroscopy (LIBS). However, these systems are more cost-intensive and less robust than nonintensified CCDs. The objective of this paper is to compare, both theoretically and experimentally, the performance of an intensified (ICCD) and nonintensified (CCD) detectors for detection of plasma emission in LIBS. The CCD is used in combination with a mechanical chopper, which blocks the early continuum radiation from the plasma. The detectors are attached sequentially to an echelle spectrometer under the same experimental conditions. The laser plasma is induced on a series of steel samples under atmospheric conditions. Our results indicate that there is no substantial difference in the performance of the CCD and ICCD. Signal-to-noise ratios and limits of detection achieved with the CCD for Si, Ni, Cr, Mo, Cu, and V in steel are comparable or even better than those obtained with the ICCD. This result is further confirmed by simulation of the plasma emission signal and the corresponding response of the detectors in the limit of quantum (photon) noise.
Laser-induced breakdown spectroscopy has been used for quantitative measurement of trace elements, e.g. sulfur and chlorine, in concrete. Chloride and sulfate ions have a large effect on the durability of concrete structures, and quantitative measurement is important for condition assessment and quality assurance. Concrete is a highly heterogeneous material in composition and grain-size distribution, i.e. the spatial distribution of elements. Calibration plots were determined by use of laboratory-made reference samples consisting of pressings of cement powder, hydrated cement, cement mortar, and concrete, in which the heterogeneity of the material is increasing because of the aggregates. Coarse aggregate and cement paste are distinguishable by the intensity of the Ca spectral lines. More advanced evaluation is necessary to account for the effect of the fine aggregate. The three series of reference samples enable systematic study of the effects of heterogeneity on spectral intensity, signal fluctuation, uncertainty, and limits of detection. Spatially resolved measurements and many spectra enable statistical evaluation of the data. The heterogeneity has an effect on measurement of the sulfur and chlorine content, because both occur mainly in the cement matrix. Critical chloride concentrations are approximately 0.04% (m/m). The chlorine spectral line at 837.6 nm is evaluated. The natural sulfur content of concrete is approximately 0.1% (m/m). The spectral line at 921.3 nm is evaluated. One future application may be simultaneous determination of the amount of damaging trace elements and the cement content of the concrete.