Spices have an important impact on daily aliment. Changes of their quality resulting in far reaching consequences in different foodstuffs and imply financial losing and even health hazard. In this study it is demonstrated that application of two different portable multi gas sensors (electronic nose and ion mobility spectrometer) supported by multivariate data analysis can contribute to ensure quality control of spice mixtures and to find out product adulteration. Headspace above spice mixtures for sausages and saveloy and product counterfeitings was investigated by a metal oxide based electronic nose (e-nose of KAMINA-type). Linear discriminant analysis (LDA) of sensor resistivity data was performed for differentiation. Simultaneously an ion mobility spectrometer (IMS) was coupled to the emission chamber for detection of gaseous components above spice mixtures. The measured spectra show differences between the two spice mixtures and were discussed using a principal component analysis (PCA). The two multigas sensors permit discrimination between the types of spice mixtures and can indicate product adulteration. Additionally, a headspace gas analysis by gas chromatography was performed to identify the main volatile components and to prove the chemical basis for the observed differences of the multi gas sensors.
The performance of twelve laboratories with previously established proficiency in the determination of the mineral oil content in a fresh water sediment is described. The summation parameter total petrol hydrocarbon (TPH) is defined according to ISO 16703:2004 with regard to the sample preparation to be applied, the flame ionisation detection (FID) and the boiling range of C10C40 to be integrated. Comprehensive tests of homogeneity and stability have been carried out on the candidate material using appropriate models. The outcome of the study served as the basis for the certification of the candidate reference material as ERM-CC015a. The certified mass fraction is 1,820±130mgkg-1 and traceability was established by using an appropriate calibration standard certified for the mass fraction of C10C40. The interlaboratory scatter of measurement results in this exercise can largely be explained by the variability of the individual calibrations based on this common calibration standard.
Determination of pentachlorphenol (PCP) in waste wood - method comparison by a collaborative trial
(2002)
Two independently developed and validated procedures for the determination of pentachlorophenol (PCP) in waste wood were compared by means of a collaborative trial. Both methods foresee quantification of PCP by gas chromatography (GC-ECD) after acetylation and differ with regard to the use of methanol or toluene/sulphuric acid, respectively, as solvent in the sonication extraction step. Test samples with established analyte homogeneity were prepared from a ground real life starting material. A total of 23 participating laboratories with experience in wood preservative analysis were instructed to apply both methods to three levels of content in the range of 0.520 mg PCP/kg. In case of the toluene/sulphuric acid extraction, lower recoveries and higher interlaboratory dispersion of results at the higher PCP contents were observed. Seen against the background of the Horwitz equation a reproducibility standard deviation of not, vert, similar19% for the methanol extraction at the 4.5 mg/kg level meets the requirement for a sound analytical method. Thus, the sonication extraction procedure with methanol has been annexed as a reference method to the German waste wood regulation.
Process waters obtained from hydrothermal carbonization (HTC) of wheat straw, a biogas digestate derived thereof, and four woody biomass feedstocks were quantified regarding the total organic carbon (TOC) and selected organic compounds. HTC runs revealed that TOC loads were largely unaffected by process severity or type of feedstock whereas the C2–C6 fatty acids, determined by GC, displayed clear effects of temperature and feedstock. HPLC demonstrated simultaneously the initial increase and subsequent consumption of cellulose-derived furfural and 5-hydroxymethylfurfural as well as the increase of the lignin-derived 2-methoxyphenol. 2-Methylbenzofuran, an example for a substance potentially harmful to aquatic biota, was observed in high concentration in the HTC liquor from wheat straw-based feedstocks.
Due to the utilisation of 1,1,2-trichlorotrifluoroethane (CFE) as extraction solvent the IR-spectrometric determination of total petrol hydrocarbon (TPH) in soil according to ISO/TR 11046 has been replaced by gas chromatography/flame ionisation detection (GC/FID) after extraction with a halogen-free solvent according to ISO/DIS 16703:2001. The results obtained with both methods by field laboratories in three proficiency testing (PT) rounds are compared. The consensus means obtained with GC/FID are typically 10%-20% (ranging between 0% and 25%) higher than those found with IR-spectroscopy. On the contrary, coefficients of variation (CV) are roughly double in case of GC/FID and are briefly discussed against the background of the Horwitz equation.
In order to determine the relevance of microplastic particles in various environmental media, comprehensive investigations are needed. However, no analytical method exists for fast identification and quantification. At present, optical spectroscopy methods like IR and RAMAN imaging are used. Due to their time consuming procedures and uncertain extrapolation, reliable monitoring is difficult. For analyzing polymers Py-GC-MS is a standard method. However, due to a limited sample amount of about 0.5 mg it is not suited for analysis of complex sample mixtures like environmental samples. Therefore, we developed a new thermoanalytical method as a first step for identifying microplastics in environmental samples. A sample amount of about 20 mg, which assures the homogeneity of the sample, is subjected to complete thermal decomposition. The specific degradation products of the respective polymer are adsorbed on a solid-Phase adsorber and subsequently analyzed by thermal Desorption gas chromatography mass spectrometry. For certain identification, the specific degradation products for the respective polymer were selected first. Afterwards real environmental samples from the aquatic (three different rivers) and the terrestrial (bio gas plant) systems were screened for microplastics. Mainly polypropylene (PP), polyethylene (PE) and polystyrene (PS) were identified for the samples from the bio gas plant and PE and PS from the rivers. However, this was only the first step and quantification measurements will follow.
The aim of this study was to identify specific truffle marker substances within the truffle aroma. The aroma profile of different truffle species was analyzed using static headspace sampling with gas chromatography mass spectrometry analysis (SHS/GC-MS). Possible marker substances were identified, taking the additional literature into account. The selected marker substances were tested in an experiment with 19 truffle dogs. The hypothesis “If trained truffle dogs recognize the substances as supposed truffles in the context of an experiment, they can be regarded as specific” was made. As it would be nearly impossible to investigate every other possible emitter of the same compounds to determine their specificity, this hypothesis was a reasonable approximation. We were interested in the question of what it is the dogs actually search for on a chemical level and whether we can link their ability to find truffles to one or more specific marker substances. The results of the dog experiment are not as unambiguous as could have been expected based on the SHS/GC-MS measurements. Presumably, the truffle aroma is mainly characterized and perceived by dogs by dimethyl sulfide and dimethyl disulfide. However, as dogs are living beings and not analytical instruments, it seems unavoidable that one must live with some degree of uncertainty regarding these results.
The ISO 16000-6 standard gives directions to adapt the analysis of volatile organic compounds (VOCs) in indoor and test chamber air to very volatile organic compounds (VVOCs). The same techniques with sorbent-based active sampling, thermal desorption and gas chromatography coupled with mass spectrometry (TD-GC/MS) should be used. However, VVOCs require gaseous standards, an adapted GC column and a reliable sampling adsorbent. This work presents experimental results to tackle those three experimental gaps. A stable standard gas mixture containing 47 VVOCs, 13 VOCs and an internal standard was successfully generated. It was employed to study the suitability of seven types of chromatography columns. The use of PLOT (Porous Layer Open Tubular) columns such as PoraBOND Q is well suitable for VVOC analysis. The recoveries of the 60 analytes on a total of 16 adsorbents and their combinations were determined: A combination of the graphitized carbon black Carbograph 5TD 40/60 and the carbon molecular sieve CarbosieveTM SII showed great recoveries for all analytes. Carbon molecular sieves adsorb water which can impair the analysis. A dry purge of the multi-sorbent in the sampling direction led to a complete water removal and promising recoveries of the analytes.
The ISO 16000-6 standard describes a method for the determination of volatile organic compounds (VOCs) in indoor and test chamber air by sorbent-based active sampling, thermal desorption and gas chromatography coupled with mass spectrometry (GC/MS). It also gives directions to adapt this methodology to very volatile organic compounds (VVOCs). Indeed, toxicologically based guideline values are being implemented for these compounds and it becomes necessary to measure them. But a comprehensive and robust measurement method is lacking. This work highlights the points that still need to be explored towards the standardisation of a suitable procedure: investigations on sorbent combinations, the suitability of chromatography columns and the use of gaseous standards are required. The biggest challenge remains in the fact that strong sorbents adsorb water together with VVOCs. Water may impair the analysis and the optimal approach to eliminate it is still to be found and integrated into the sampling strategy.
On the use of Carbograph 5TD as an adsorbent for sampling VVOCs: validation of an analytical method
(2023)
A standardised method for the analysis of very volatile organic compounds (VVOCs) in indoor air is still missing. This study evaluates the use of Carbograph 5TD as an adsorbent for 60 compounds (47 VVOCs + 13 VOCs) by comparing their recoveries with different spiking modes. The influence of the spiking of the tubes in dry nitrogen, humidified air or along the whole flushing duration mimicking real sampling was investigated. 49 substances (36 VVOCs from C1 to C6) had recoveries over 70% on the adsorbent in humidified air and were validated. The linearity of the calibration curves was verified for every spiking mode and the limits of detection (LOD) and quantification (LOQ) were determined. The LOQs were lower than the existing indoor air guideline values. The robustness of the method was considered by studying the influence of the sampling volume, the sampling flow rate, the humidity level and the storage of the tubes. In general, the most volatile or polar substances were the less robust ones. The combined measurement uncertainty was calculated and lies below 35% for a vast majority of the substances. An example of an emission chamber test using polyurethane foam is shown: Carbograph 5TD performs much better than Tenax® TA for VVOCs and emissions from n-butane were quantified with combined measurement uncertainty.