Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (30)
- Vortrag (30)
- Posterpräsentation (7)
- Beitrag zu einem Tagungsband (3)
- Sonstiges (3)
- Buchkapitel (2)
- Forschungsbericht (2)
- Beitrag zu einem Sammelband (1)
Sprache
- Englisch (78) (entfernen)
Schlagworte
- Reference materials (78) (entfernen)
Organisationseinheit der BAM
- 6 Materialchemie (22)
- 1 Analytische Chemie; Referenzmaterialien (18)
- 6.1 Oberflächen- und Dünnschichtanalyse (14)
- 6.6 Physik und chemische Analytik der Polymere (9)
- 1.2 Biophotonik (7)
- 1.4 Prozessanalytik (4)
- 1.6 Anorganische Referenzmaterialien (4)
- 4 Material und Umwelt (4)
- 4.2 Material-Mikrobiom Wechselwirkungen (3)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (3)
The talk summarizes challenges in microplastic analysis. It shows the preparation of microplastic reference materials as well as the testing on homogeneity and stability. The reference material is used in an international laboratory comparison to compare different detection methods used for microplastic analysis. The methods used were µ-IR (FTIR+LDIR) for number-based methods and TED-GC/MS and Py-GC/MS for mass-based methods. The ILC was done under the umbrella of VAMAS TWA 45. Results of the participants are presented.
Since microplastics (MPs) can be found everywhere and are becoming a problem of high concern, it is necessary to understand their physico-chemical properties. To obtain reliable analytical data a set of validated methods for sampling, sample preparation, detection, and data evaluation are needed.
To meet these needs an interlaboratory comparison (ILC) with 84 participants worldwide has been organized under the international pre-standardisation platform VAMAS (www.vamas.org/twa45/) as Project 2 “Development of standardized methodologies for characterisation of microplastics with microscopy and spectroscopy methods” within the Technical Working Area TWA 45 “Micro and Nano Plastics in the Environment”. In this ILC thermo-analytical methods (Py-GC/MS and TED-GC/MS) and vibrational methods (µ-Raman and µ-FTIR) have been tested and compared by providing a set of microplastic representative test materials and measurement protocols developed at BAM. The defined measurands were: particle number concentration, particle size distribution (PSD), and polymer identity and mass content. To increase the statistical quality, 6 samples were shipped together with blank samples. Hence, the ILC provides information on precision and accuracy of the results obtained with different methods as well as strengths and limitations of the proposed protocols.
Ergot alkaloids form a toxicologically relevant group of mould toxins (mycotoxins) that are among the most common contaminants of food and animal feed worldwide. Reliable controls are essential to minimise health risks and economic damage. Due to their toxicological relevance, EU limit values for 12 priority ergot alkaloids have been introduced for the first time in 2022 and range from 500 µg/kg in rye milling products down to 20 ug/kg Processed cereal-based foods for infants and young children[1]. High-performance liquid chromatography - mass spectrometry is used to quantify low concentrations of ergots in food, however the European standard analytical procedure cannot be applied due to the lack of isotopically labelled reference standards.
The complex structure of the ergot alkaloids makes a total synthesis extremely challenging, expensive and time-consuming. Therefore, we are focusing on different semi-preparative methods (electrochemistry, organic synthesis, heterogeneous catalysis) to specifically N-demethylate the C8 carbon atom of the lysergic acid moiety. The norergot alkaloid formed is then isotopically labelled using an electrophilic methyl source, i.e. iodomethane or dimethyl sulphate to obtain the specific isotopic labelled ergot alkaloid. Initial experiments have shown that N-demethylation of the ergot alkaloid ergotamine is possible by both electrochemical and wet-chemical organic synthesis. The next step is to adapt the previously determined reaction conditions to enable the synthesis of norergotamine on a mg scale.
AbstractWe report on gold clusters with around 62 gold atoms and a diameter of 1.15±0.10 nm. Dispersions of the clusters are long‐term stable for two years at ambient conditions. The synthesis was performed by mixing tetrachloroauric acid (HAuCl4 ⋅ 3 H2O) with the ionic liquid 1‐ethyl‐3‐methylimidazolium dicyanamide ([Emim][DCA]) at temperatures of 20 to 80 °C. Characterization was performed with small‐angle X‐ray scattering (SAXS), UV‐Vis spectroscopy, and MALDI‐TOF mass spectrometry. A three‐stage model is proposed for the formation of the clusters, in which cluster growth from gold nuclei takes place according to the Lifshitz‐Slyozov‐Wagner (LSW) model followed by oriented attachment to form colloidal stable clusters.
The VAMAS/TWA 45 Project 2 “Development of standardized methodologies for characterisation of microplastics with microscopy and spectroscopy methods” involving 85 participants around the world is primarily discussed with respect to the results received and a first data evaluation. Status of the Project "Guidelines for defining reference materials for plastic degradation in marine environment" is reported and two new project proposals are presented: "Development of standardized methodologies for characterisation of nanoplastics (starting soon, BAM as leader?) and "Development of analytical protocols for the identification and quantification of microplastics of fibrous shape (still in negotiation)".
Quantitative 1H Nuclear Magnetic Resonance (qNMR) of Aromatic Amino Acids for Protein Quantification
(2023)
Hydrolysis of protein samples into amino acids facilitates the use of NMR spectroscopy for protein and peptide quantification. Different conditions have been tested for quantifying aromatic amino acids and proteins. The pH-dependent signal shifts in the aromatic region of amino acid samples were examined. A pH of 12 was found to minimize signal overlap of the four aromatic amino acids. Several aromatic compounds, such as terephthalic acid, sulfoisophthalic acid, and benzene tricarboxylic acid, were applied as internal standards. The quantification of amino acids from an amino acid standard was performed. Using the first two suggested internal standards, recovery was ~97% for histidine, phenylalanine, and tyrosine at a concentration of approximately 1 mM in solution. Acidic hydrolysis of a certified reference material (CRM) of bovine serum albumin (BSA) and subsequent quantification of Phe and Tyr yielded recoveries of 98% ± 2% and 88% ± 4%, respectively, at a protein concentration of 16 g/L or 250 µM.
Benchtop 1H-NMR and FTIR have both been successfully developed for size-exclusion chromatography (SEC) applications. The latest implementations of these methods by Wilhelm and collaborators[1-3] have taken advantage of commerically available low-cost equipment, and a provide a means to obtain slice-by-slice spectra for the monitoring of functional groups in polymer separations. Demonstrated applications include the detection of highly diluted chains in a polymer blend (e.g., PS/PMMA), copolymer content determination (e.g., styrene-methyl methacrylate), and butadiene isomer detection. To synthesize and characterize an end-labelled low molecular wt. poly(ethylene glycol) as a model polymer to aid in the development and validation of spectroscopic detection (FTIR and 1H-NMR) for SEC applications. A particular focus is to improve quantitation and/or detection of highly diluted funtional groups (e.g., polymer chain ends or sparsely functionalized chains) In the first approach, an isocyanate with IR- and NMR-active functional groups was reacted with PEG (4000 and 10000 g/mol) to form end-functionalized chains by means of an addition reaction. The functionalization of the 10000 g/mol PEG was found to be non-homogeneous (not discussed further). The 4000 g/mol PEG was successfully functionalized to 100%, found to be homogeneous across the molecular weight distribution and could therefore serve as a model polymer for analysis by the coupled methods.